• Title/Summary/Keyword: Fiber-optic interferometer

Search Result 103, Processing Time 0.022 seconds

Buried Fiber Optic Intrusion Sensor (매설형 광섬유 침입자 센서)

  • Park, Jae-Hee;Kim, Myung-Gyoo;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.1-6
    • /
    • 1996
  • The feasibility of producing a practical buried fiber optic sensor with high sensitivity for detecting intruders is demonstrated. Experiments were carried out with the use of an all fiber Michelson interferometer, the sensing arm of which was buried in sand. When the sensing arm was buried 8 inches deep in sand, the pressure length product required for a half fringe shift in: the sensor output was $1.09\;kPa{\cdot}m$. The relation between the applied weight and the phase change was almost linear. Experimental results indicated that the sensitivity of the optical fiber sensor was sufficient to detect people on foot and vehicles passing over the buried fiber.

  • PDF

FBG Sensor Demodulation Using a Double-Pass Mach-Zhender Interferometer (더블패스 마하젠더 간섭계를 이용한 광섬유 격자 센서의 파장복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • A wavelength-demodulation algorithm for FBG sensor is proposed by using a double-pass Mach-Zehnder interferometer. Zero-crossing points of double-passed interference signal are used to trigger the accurate $90^{\circ}C$ phase difference positions in the sensor signal, which is an essential condition in the subsequent arctangent and phase unwrapping signal processing. With the proposed method, we could efficiently measure various measurands, such as dynamic-, static-strain, and temperature, and ${\sim}8pm$ of wavelength resolution was obtained.

Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film (유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성)

  • Kim, M.G.;Yoo, Y.W.;Kwon, D.H.;Lee, J.H.;Kim, J.S.;Park, J.H.;Chai, Y.Y.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.147-153
    • /
    • 1998
  • The strain characteristics of a fiber optic Fabry-Perot pressure sensor with high sensitivity using a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ (N/O/N) diaphragm is experimentally investigated. A 600 nm thick N/O/N diaphragm was fabricated by silicon anisotropic etching technology in 44 wt% KOH solution. An interferometric fiber optic pressure sensor has been manufactured by using a fiber optic Fabry-Perot intereferometer and a N/O/N diaphragm. The 2 cm length fiber optic Fabry-Perot interferometers in the continuous length of single mode fiber were produced with two pieces of single mode fiber coated with $TiO_{2}$ dielectric film utilizing the fusion splicing technique. The one end of the fiber optic Fabry-Perot interferometer was bonded to a N/O/N diaphragm. and the other end was connected to an optical setup through a 3 dB coupler. For the N/O/N diaphragm sized $2{\times}2\;mm^{2}$ and $8{\times}8\;mm^{2}$, the pressure sensitivity was measured 0.11 rad/kPa and 1.57 rad/kPa, respectively, and both of the nonlinearities were less than 0.2% FS.

  • PDF

A Study on the Characteristics analysis of Optic Tunable Filter Using Fabry-Perot Interferometer (FPI를 이용한 파장가변 광 필터 특성분석에 관한 연구)

  • Jang, Woo-Soon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.3-6
    • /
    • 2005
  • In this thesis, We researched on the characteristics of optical tunable filter that selects the channel by the wavelength changes of transmission spectrum when we apply outer physical quantities on a fiber bragg grating by using Fabry-Perot Interformer's operational principle.

  • PDF

Ultrasonic-detecting Characteristics by Partial Discharge using the Fiber Mach-Zehnder Interferometerin Insulating Oil (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 심승환;이광식;이상훈;김달우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.325-328
    • /
    • 2002
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise, gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. In this paper, an optical fiber sensor utilizing the principal of Mach-Zehnder interferometer was proposed to detect the discharge signal.

  • PDF

Ultrasonic-detection characteristics of optical-fiber sensor for insulation diagnosis (절연진단용 광섬유 센서의 초음파 검출특성)

  • Lee, S.H.;Sim, S.H.;Lee, K.S.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.183-186
    • /
    • 2002
  • It is well known that a discharge in oil is the source of various physical and chemical phenomena. One of them is ultra-sonic wave, and its detection is a useful method to the diagnosis of the transformer insulation condition. Conventionally, ultra-sonic waves are detected by Piezo-electric trans-ducer(PZT), and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test of the ultrasonic-detecting ability was performed for both of PZT and fiber-optic sensor. Discharge test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and showed time-delay characteristics. We analyzed the data with frequency domain and wavelet transform.

  • PDF

Fiber Optic AC Voltage Sensor Using Fringe Counting (간섭무늬의 변화갯수 측정을 이용한 광섬유 교류전압센서)

  • 김봉규;김병윤;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.158-165
    • /
    • 1994
  • A fiber optic voltage sensor is demonstrated with a new signal processing scheme that displays the magnitude and the waveform of applied voltage with immunity from the signal frequency change. The sensor is based on a Mach-Zehnder interferometer with a PZT phase modulator as a sensing element. We observed a linear relationship between applied voltage and the number of fringe shift during a half cycle of the ac signal. The temperature dependence of the sensor output is experimentally evaluated over the temperature range from $-20^{\circ}C to 80^{\circ}C$. It is demonstrated that the detrimental polarization modulation effect can be overcome by using polarization maintaining fibers or a half-wave plate. plate.

  • PDF

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.

Characteristics Investigation and Design of the Mandrel for Fiber Optic Acoustic Sensor (광섬유 음향 센서용 맨드릴 설계 및 특성 연구)

  • Lee, Jongkil;Ha, Tae-Hyun;Lee, June-Ho
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.331-345
    • /
    • 2009
  • In this research Sagnac interferometer three different types of mandrel are suggested and this fiber optic sensor is using in monitoring of electric transformer. Vibration characteristics of those mandrels were analyzed and finally more sensitivity mandrel are suggested. Three different mandrels using in fiber optic sensor are hollow cylinder with outer bump, pure hollow cylinder, hollow cylinder with inner bump. Natural frequencies and mode shapes are investigated using finite element method. Mode shape are considered at the frequency range from 2 kHz to 20 kHz. Fundamental dimensions of the hollow cylinder type's mandrel are 30 mm in outer diameter, 50 mm in length, 1 mm in cylinder thickness, $2mm{\times}2mm$ in bump size. Based on the finite element results, when the outer acoustic frequency is near 11 kHz outer bump type and hollow cylinder can get higher sensitivity. Near 17 kHz outer bump and inner bump mandrel can get higher sensitivity. Near 20 kHz hollow cylinder and inner bump mandrel is useful. This results can be applied to design of fiber optic sensor using in monitoring the electrical transformer. Several MHz of outer acoustic frequency can be easily detected using more sensitive mandrel in pursuing expand this technique.

Fabrication of $TiO_{2}$ In-line Reflection Mirror and Its Characteristics for Fiber Optic Fabry-Perot Interferometric Sensor (광섬유 Fabry-Perot 간섭형 센서 제조를 위한 $TiO_{2}$ 반사막의 형성 및 그 특성)

  • Park, Dong-Soo;Kim, Myung-Gyoo;Kim, Chang-Won;Lee, Jung-Hee;Kang, Shin-Won;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.71-79
    • /
    • 1995
  • For the fabrication of high sensitive intrinsic fiber optic Fabry-Perot interferometeric sensor, the deposition conditions of $TiO_{2}$ thin film used to the internal mirrors of the sensor were investigated. The $TiO_{2}$ film deposited by RF magnetron sputter had higher refractive index ($2.36{\sim}2.48$) and better stoiciometry (O/Ti = 2) than that deposited bye-beam evaporator. In the case of forming $TiO_{2}$ internal mirror by using fusion splicing technique, the $TiO_{2}$ reflection mirror deposited by RF magnetron sputter in the condition of 120W RF power showed high. reflectance and excellent controllability of reflection power. The fabricated intrinsic fiber optic Fabry-Perot interferometer with two $TiO_{2}$ internal mirrors deposited under the condition showed very stable fringe patterns. It is, therefore, expected that the interferometer will be applicable to various high precision sensors.

  • PDF