• 제목/요약/키워드: Fiber-optic detector

검색결과 37건 처리시간 0.023초

급탄관 온도 측정시스템의 특성 비교분석에 관한 연구 (A study on the characteristic comparision of systems which measure the temperature of coal powder in feader lines of boiler)

  • 오면택;이복규;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.597-600
    • /
    • 1996
  • This study has compared the two types of systems which measure the temperature of coal powder in feeder lines of boiler and analyzed operating data. We used RTD(Resistance Temperature Detector) and optic sensors to measure the temperature. From the characteristic comparison of data, field test and system operation, we confirm that the latter is more efficient than the former.

  • PDF

광파이버 트랜스듀서에 의한 맥파의 무침습적 검출 (Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer)

  • 박승환;정동명
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가 (Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material)

  • 황영묵;조동현;이봉수;조효성;김신
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

Optimization of a fiber optic probe for non-invasive blood glucose monitoring

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Lee, Hyun-Chul;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.407.3-408
    • /
    • 2002
  • A portable near infrared (NIR) system which was newly integrated by our lab has been used to develop a non-invasive blood glucose monitoring. The portable NIR system includes a tungsten halogen lamp, a photo diode array type-InGaAs detector, and specialized reflectance fiber optic probes. The shape of probes is composed of two parts. one for illumination into sample and the other for receiving the radiation from sample. Three kinds of probes with different distance between illumination and receiving part. such as 0.03. 0.1. and 0.5mm, were investigated for optimization. (omitted)

  • PDF

주파수 천이를 이용한 광무선 시스템에서 EOM의 바이어스 방식에 따른 광 링크 성능 분석 (Optic link performances on EOM's biasing in fiber-radio system)

  • 오세혁;양훈기;최영완
    • 대한전자공학회논문지SD
    • /
    • 제38권2호
    • /
    • pp.42-42
    • /
    • 2001
  • 본 논문은 주파수 천이를 적용시킨 광무선(fiber-radio)시스템의 광링크부에 대한 성능분석을 한다. 제시된 광링크부는 CS(control station)에서 얻어진 밀리미터파 대역 광파일럿톤(optical pilot tone)이 하향링크뿐 아니라 상향링크에도 공급되도록 하여 BS(base station)의 구조를 간단히 하였다. 광파일럿톤을 얻기 위해 CS의 EOM(electro-optic modulator)을 MAB(maximum bias), MIB(minimum bias), QB(quadrature bias)로 바이어스를 달리할 수 있으며 각각의 경우에 따라 링크의 성능을 분석한다. 분석은 레이저 광원의 전력이 일정한 경우와 PD(photo detector)에 수신되는 광 DC 전력이 일정한 경우에 대해서 행하여지며 각 경우에 대해서 최적의 하향링크 CNR 및 상향링크 SFDR(spurious free dynamic range)을 얻기 위해 효과적인 바이어스 방식을 제시한다

휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Noninvasive blood glucose monitoring system based on NIR spectroscopy with a contact pressure control device

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.67.3-68
    • /
    • 2003
  • The purpose of this study is to improve repeatability of a non-invasive blood glucose measurement. The portable NIR system that was newly integrated by our lab includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of finger tip were recorded by using a fiber optic probe. The probe was fixed in the system and subjects put their finger on the probe head. (omitted)

  • PDF

유기인화합물 측정용 광바이오센서 개발 (Development of Prototype Biosensor for The Detection of Organophosporus Compounds)

  • 최정우;김종민;이원홍;김영기
    • KSBB Journal
    • /
    • 제17권2호
    • /
    • pp.158-161
    • /
    • 2002
  • 본 연구에서는 화학무기, 농약 등에 사용되는 신경독성물질인 유기인화합물의 측정을 위하여 유기인화합물의 효소반응 저해작용을 이용한 광바이오센서장치의 시제품을 제작하였다. 효소반응을 위하여 효소로는 신경세포의 필수효소인 acetylcholinesterase, acetylthiocholine iodide을 사용하였으며 효소반응의 저해제인 유기인화합물로는 paraoxon을 사용하였다. 센서의 폭정원리는 유기인화합물에 의해 저해된 효소반응정도를 효소반응의 생성물인 아세트산의 정량적 측정으로 분석하였으며, pH에 의하여 최대 흡광파장의 변화가 일어나는 litmus를 사용하여 흡광도 측정으로 아세트산의 정량분석을 수행하였다. 광바이오센서 시제품의 제작은 광원으로 고취도 LED와 광세기 측정을 위한 photodiode로 구성하였으며, 제작된 센서를 이용한 실험결과로부터 0 ppm에서 2 ppm의 paraoxon 농도에서 구성된 센서시스템의 선형적 신호 변화를 관찰하였다. 이상의 실헐결과로부터 광바이오센서 시제품은 2분의 반응시간으로 신속하고 정확한 유기인화합물의 정량분석이 가능함을 확인하였다.

Laser Diode Tester 개발과 비젼 피드백을 이용한 위치 보정 (Development of Laser Diode Tester and Position Compensation using Feedback with Machine Vision)

  • 김재희;유철우;박상민;유범상
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.30-36
    • /
    • 2004
  • The development of LD(Laser Diode) tester and its control system based on the graphical programming language(LabVIEW) is addressed. The ill tester is used to check the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the Detector(optic fiber and photo diode) are very small, therefore the test device needs high accuracy. But each motion part of the test device could not accomplish high accuracy due to the limit of the mechanical performance. So, an image processing with machine vision is proposed to compensate for the error. By adopting our method we can reduce the error of position within $\pm$5$\mu\textrm{m}$.

A Comparison of Signal Processing Techniques in Optical Current Sensor for GIS

  • Kim, Young-Min;Park, Jung-Hwan;Jee, Seung-Wook;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.103-109
    • /
    • 2006
  • This research is contents about output characteristic of optic current sensor that use faraday effect. optic current sensor used in an experiment is consisted of three parts.(1) Source of light used laser diode of 1310[nm].(2) Sensor section manufactured circularly according to gas insulated switchgear. And $9/125[{\mu}m]$ standard single mode optical fiber for communication was installed winding 20 [turn] on sensor section core surroundings of diameter 31 [cm].(3) Electrical signal of PD(Photo detector) is collected using NI company's 16bit DAQ board via terminal block. Collected data analyzed by different three signal processing methods. NI company's $Labview^{TM}$ was used to signal processing software. As a result, In signal processing of optic current sensor, we could know that noise greatly more influences the error generation than fluctuation of light intensity. also, 1 class CT(current transformer) manufacture that have error rate less than 1[%] was available by removing these