• Title/Summary/Keyword: Fiber-Optic

Search Result 1,082, Processing Time 0.023 seconds

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.

Molding Quality Evaluation on Composite Laminate Panel for Railway Vehicle through Cure Monitoring using FBG Sensors (광섬유 FBG 센서기반 성형 모니터링을 통한 철도 차량용 복합재 내장재 패널의 성형 품질 평가)

  • Juyeop Park;Donghoon Kang
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.186-192
    • /
    • 2023
  • Recently, in the field of railway vehicles, interest in the use of composite materials for weight reduction and transportation efficiency is increasing. Accordingly, research and commercialization development to apply composite materials to various vehicle parts are being actively conducted, and evaluation is conducted centering on post-measurement such as mechanical performance evaluation of finished products to verify quality when composite materials are applied. However, the analysis of heat and stress generated during the molding process of composite materials, which are factors that greatly affect manufacturing quality, is insufficient. Therefore, in this study, in order to verify the molding quality of composite parts for railway vehicles, the molding quality analysis was conducted for the two types of composite interior panels (laminate panel and sandwich panel) that are most actively used. To this end, temperature and strain changes were monitored during the molding process by using an FBG fiber optic sensor, which is easy to apply to the inside of the composite, and the residual strain value generated after molding was completed was measured. As a result, it was confirmed that overheating and excessive residual stress did not occur, thereby verifying the excellent molding quality of the composite interior panel for railway vehicles.

Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment (세포 실험용 다중 주파수 동시 노출 장치 제작)

  • Kim, Tae-Hong;Seo, Min-Gyeong;Mun, Ji-Yeon;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.213-219
    • /
    • 2012
  • Recently, we are simultaneously exposed by various electromagnetic sources due to an increase of mobile communication services. However, EMF(Electric, Magnetic and Electromagnetic Field) study has been performed mainly about only single frequency. The objective of this paper is to develop an multiple-frequency exposure system for in vitro experiment. The exposure unit for in vitro experiments was designed by radial transmission line type to get broadband characteristics to generate signals of CDMA at 836.5 MHz and WCDMA at 1950 MHz frequency simultaneously. The modulated signals were delivered to the conical antenna through amplifier, digital attenuator and RF combiner. SAR values were obtained by the averaged values of 3 measured values at 9 points in petri dish using the fiber optic temperature probe. The measured return loss was under -15 dB. For 1 W input power, the mean value and standard deviation of SAR were $0.105{\pm}0.019$ for the CDMA frequency and $0.262{\pm}0.055$ for the WCDMA frequency.

Determination of the water content in citrus leaves by portable near infrared (NIR) system (근적외분광분석법을 이용한 감귤잎의 수분 측정)

  • Suh, Eun-Jung;Woo, Young-Ah;Lim, Hun-Rang;Kim, Hyo-Jin;Moon, Doo-Gyung;Choi, Young-Hun
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.277-282
    • /
    • 2003
  • The amount of water for the cultivation of citrus is different based on the growing period. The effect of water stress induces to enhance of sugar accumulation in citrus. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine the water content of citrus leaves non-destructively by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from 'Okitsu' Satusuma mandarin leaves (Citrus unshiu Marc.) ranging from 20.80 to 69.98% of water content by loss on drying method, and NIR reflectance spectra of citrus leaves were acquired by using a fiber optic probe. It was found that the variation of absorbance band 1450 nm from OH vibration of water depending on the water content change. Partial least squares regression (PLSR) was applied to develop a calibration model over the spectral range 1100-1700 nm. The calibration model predicted the water content for the validation set with a standard errors of prediction (SEP) of 0.97%. In order to validate the developed calibration model, routine analyses were performed using independently prepared citrus leaves. The NIR routine analyses showed good results with those of loss on drying method with a SEP of 0.81%. The rapid and non-destructive determination of the water content in citrus leaves was successfully performed by portable NIR system.

Structural and Optical Properties of Self-assembled InAs/InAl(Ga)Ae Quantum Dots on InP (InP 기판에 성장한 자발형성 InAs/InAl(Ga)As 양자점의 구조 및 광학적 특성)

  • Kim Jin-Soo;Lee Jin-Hong;Hong Sung-Ui;Kwack Ho-Sang;Choi Byung-Seok;Oh Dae-Kon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.194-200
    • /
    • 2006
  • Self-assembled InAs/InAl(Ga)As quantum dots (QDs) were grown on InP substrates by a molecular-beam epiaxy, and their structural and optical properties were investigated by atomic force microscopy (AFM), transmission electron microscopy (TEM), and room-temperature photoluminescence (PL). AFM images indicated that the InAs quantum structures showed various shapes such as quantum dashes, asymmetric and symmetric QDs mainly caused by the initial surface conditions of InAl(Ga)As with the intrinsic phase separation. For the buried InAs QDs in an InAlGaAs matrix, the average lateral size and height of QDs were 23 and 2 nm, respectively. By changing the growth conditions for the QD samples, the emission wavelength of $1.55{\mu}m$ was obtained, which is one of the wavelength windows for fiber optic communications.

Ultrastructure of the Eye in the Snail, Incilaria fruhstorferi (산민달팽이 (Incilaria fruhstorferi) 눈의 미세구조)

  • Chang, Nam-Sub;Han, Jong-Min;Lee, Kwang-Joo
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.363-377
    • /
    • 1998
  • After the investigation on the eye of Incilaria fruhstorieri with light and electron microscopes, the following results were obtained. The eye of Incilaria fruhstorferi comprises cornea, lens, vitreous body, retina, and optic nerve inward from the outside. Cornea is composed of squamous, cuboid, columnar and irregular cells, which appear to be light due to their low electron density. In their cytoplasms, glycogen granules, multivesicular body, and nucleus were observed. Vitreous body, located behind non-cellular transparent lens, is filled with long and short microvilli protruding from the retinal epithelia. Retinal epithelium, the organ to perceive objects, is divided into four parts; microvillar layer pigment layer, nuclear layer, and neutrophils layer, from the apical portion. Microvillar layer consists of the type-I photoreceptor cells and pigmented granule cells. In the apical portion of their cytoplasms, long microvilli (length, $19{\mu}m$) , short microvilli (length, $8{\mu}m$), and rolled microvilli grow thick in the irregular and mixed forms. Photoreceptor cells are classified into type-I and type-II, according to their structures. The type-I cell has the apical portion rising roundly like a fan and the lower part which looks like the helve of a fan. In the cytoplasm of the apical portion, there are clear vesicles, cored vesicles, ovoid mitochondria, and microfilaments, and in the cytoplasm of the lower part, photic vesicles with their diameters about 60nm aggregate densely. The type-II photoreceptor cell, located at the lower end of the type-I cells, has a very large ovoid nucleus 3nd no microvilli. In the cytoplasm of the type-II cell, the photic vesicles with sizes 60nm aggregate more densely than in the cytoplasm of the type-I cell. Pigmented cells are classified into type-A and type-B, according to their structures. The type-A is identified to be a large cell containing round granules (diameter, $0.5{\mu}m$) of very high electron density, while the type-B is identified as a small cell where the irregular granules (diameter, $0.6{\mu}m$) of a little lower electron density amalgamate. Nuclear layer ranges from the bottom of pigment layer to the top of the capsule, and contains three kinds of nuclei (nuclei of the type-II photoreceptor cell, pigmented granule cell, and accessory neuron). The capsules covering the outmost part of the eyeball are composed of collagenous fiber and three longitudinal muscle layers (the thickness of each longitudinal muscle layer, $0.4{\mu}m$) and thick circular muscle layer (thickness, $0.3{\mu}m$). Around the capsules, there is a neurophile layer consisting of neurons and nerve fibers. Each neuron has a relatively large ovoid nucleus for its cytoplasm, and in the karyosome, large lumps of keterochromatin form a wheel nucleus.

  • PDF

Convergence Monitoring Technologies for Traffic Tunnels - State of the Art (터널의 내공변위 자동화 계측기술 분석)

  • Chung So-Keul
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.1-8
    • /
    • 2005
  • Measurement of convergence was/is carried out manually throughout the world for tunnels under construction. However, manual method has certain limitations in terms of applicability for the tunnels in operation. This paper describes state of the art of convergence monitoring systems which are available for measuring displacement of existing tunnels. These technologies are analyzed as follows: 1 The Sofo system using the fiber optic sensors has been applied to the stress measurement of the tunnel lining. It has not yet been used for the monitoring of tunnel convergence because of its cost and reliability 2. A TPMS(Tunnel Profile Monitoring System) using tilt sensors and displacement sensors is used for the convergence monitoring of highway tunnels, subway tunnels and underground ducts. 3. A BCS(Bassett Convergence System) using a pair of tilt sensors can be used for the convergence monitoring of tunnels, however the accuracy of the measurement has to be improved because it uses AC input voltage during data acquisition. The system has to be validated before it can be applied to the tunnels in operation. Convergence monitoring systems using TPMS and/or BCS are recommended to be evaluated and improved by a series or tests in tunnels under construction in order to be applied to the main measuring section and the tunnels in operation.

A Mouse Model of Photochemically Induced Spinal Cord Injury

  • Piao, Min Sheng;Lee, Jung-Kil;Jang, Jae-Won;Kim, Soo-Han;Kim, Hyung-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.479-483
    • /
    • 2009
  • Objective : A mouse model of spinal cord injury (SCI) could further increase our basic understanding of the mechanisms involved in injury and repair of the nervous system. The purpose of this study was to investigate whether methods used to produce and evaluate photochemical graded ischemic SCI in rats, could be successfully adapted to mice, in a reliable and reproducible manner. Methods : Thirty female imprinting control region mice (weighting 25-30 g, 8 weeks of age) were used in this study. Following intraperitoneal injection of Rose bengal, the translucent dorsal surface of the T8-T9 vertebral laminae of the mice were illuminated with a fiber optic bundle of a cold light source. The mice were divided into three groups; Group 1 (20 mg/kg Rose bengal, 5 minutes illumination), Group 2 (20 mg/kg Rose bengal, 10 minutes illumination), and Group 3 (40 mg/kg Rose bengal, 10 minutes illumination). The locomotor function, according to the Basso-Beattie-Bresnahan scale, was assessed at three days after the injury and then once per week for four weeks. The animals were sacrificed at 28 days after the injury, and the histopathology of the lesions was assessed. Results : The mice in group 1 had no hindlimb movement until seven days after the injury. Most mice had later recovery with movement in more than two joints at 28 days after injury. There was limited recovery of one joint, with only slight movement, for the mice in groups 2 and 3. The histopathology showed that the mice in group 1 had a cystic cavity involving the dorsal and partial involvement of the dorsolateral funiculi. A larger cavity, involving the dorsal, dorsolateral funiculi and the gray matter of the dorsal and ventral horns was found in group 2. In group 3, most of the spinal cord was destroyed and only a thin rim of tissue remained. Conclusion : The results of this study show that the photochemical graded ischemic SCI model. described in rats, can be successfully adapted to mice, in a reliable and reproducible manner. The functional deficits are correlated an increase in the irradiation time and, therefore, to the severity of the injury. The photothrombotic model of SCI, in mice with 20 mg/kg Rose bengal for 5 minutes illumination, provides an effective model that could be used in future research. This photochemical model can be used for investigating secondary responses associated with traumatic SCI.

Study of Radio Frequency Thawing for Cylindrical Pork Sirloin

  • Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • Purpose: Radio frequency (RF) heating is a promising thawing method, but it frequently causes undesirable problems such as non-uniform heating. This can occur because of the food shape, component distribution, and initial temperature differences between food parts. In this study, RF heating was applied to the thawing of cylindrically shaped pork sirloin by changing the shape of electrodes and the surrounding temperature. Methods: Curved electrodes were utilized to increase the thawing uniformity of cylindrically shaped frozen meat. Pork sirloin in the shape of a half-circle column was frozen in a deep freezer at $-70^{\circ}C$ and then thawed by RF heating with flat and curved electrodes. In order to prevent fast defrosting of the food surface by heat transfer from air to the food, the temperature of the thawing chamber was varied by -5, -10, and $-20^{\circ}C$. The temperature values of the frozen pork sirloin during RF thawing were measured using fiber-optic thermo sensors. Results: After multiple applications of curved electrodes resembling the food shape, and a cooled chamber at $-20^{\circ}C$ the half-cylindrically shaped meat was thawed without surface burning, and the temperature values of each point were similarly increased. However, with the parallel electrode, the frozen meat was partially burned by RF heating and the temperature values of center were overheated. The uniform heating rate and heat transfer prevention from air to the food were crucial factors for RF thawing. In this study, these crucial factors were accomplished by using a curved electrode and lowering the chamber temperature. Conclusions: The curved shape of the electrode and the equipotential surface calculated from the modeling of the parallel capacitor showed the effect of uniform heating of cylindrically shaped frozen food. Moreover, the low chamber temperature was effective on the prevention of the surface burning during RF thawing.

An Analysis of FSK Transmission Characteristics of Spectrum Sliced Optical Signals (스펙트럼 분할된 광신호의 FSK 전송 특성 해석)

  • Ha, Eun-Sil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.339-344
    • /
    • 2016
  • Since transmissions of large amounts of data are frequent, users require more bandwidth, and the need for communications networks having greater bandwidth is increasing. One communications network satisfying this need is an optical communications network. Therefore, studies to increase the transmission capacity of optical communications systems have been carried out. However, in a general optical communications system, a signal transmitted through optical fiber (a transmission medium) is detected through direct detection in the receiving system. This method has a disadvantage in that the entire bandwidth of the optical signal cannot be utilized. Also, when transmitting an optical signal, there is a problem where the signal-to-noise ratio is affected by neighboring channels. To overcome this situation, various studies are being conducted to minimize the influence of external interference and noise. This paper overcomes the situation by transmitting spectrum-sliced signals using the digital transmission system, FSK. Analyzing the characteristics of the signals detected in the receiver of the optical communications system, Gaussian distribution is used for the PDF of the spectrum-sliced signal, and the signal at the receiving end of the optical communications system is assumed to have a k-square distribution. The results of the analysis confirmed it is better to transmit the spectrally divided signal rather than transmit the laser source.