• Title/Summary/Keyword: Fiber-Optic

Search Result 1,082, Processing Time 0.027 seconds

Development of TDMA-Based Protocol for Safety Networks in Nuclear Power Plants (원전 안전통신망을 위한 TDMA 기반의 프로토콜 개발)

  • Kim, Dong-Hoon;Park, Sung-Woo;Kim, Jung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.303-312
    • /
    • 2006
  • This paper proposes the architecture and protocol of a data communication network for the safety system in nuclear power plants. First, we establish four design criteria with respect to determinability, reliability, separation and isolation, and verification/validation. Next we construct the architecture of the safety network for the following systems: PPS (Plant Protection System), ESF-CCS (Engineered Safety Features-Component Control System) and CPCS (Core Protection Calculator System). The safety network consists of 12 sub-networks and takes the form of a hierarchical star. Among 163 communication nodes are about 1600 origin-destination (OD) pairs created on their traffic demands. The OD pairs are allowed to exchange data only during the pre-assigned time slots. Finally, the communication protocol is designed in consideration of design factors for the safety network. The design factors include a network topology of star, fiber-optic transmission media, synchronous data transfer mode, point-to-point link configuration, and a periodic transmission schedule etc. The resulting protocol is the modification of IEEE 802.15.4 (LR-WPAN) MAC combined with IEEE 802.3 (Fast Ethernet) PHY. The MAC layer of IEEE 802.15.4 is simplified by eliminating some unnecessary (unctions. Most importantly, the optional TDMA-like scheme called the guaranteed time slot (GTS) is changed to be mandatory to guarantee the periodic data transfer. The proposed protocol is formally specified using the SDL. By performing simulations and validations using Telelogic Tau SDL Suite, we find that the proposed safety protocol fits well with the characteristics and the requirements of the safety system in nuclear power plants.

Analysis of the Digital Phase Tracking Technique for Fiber-Optic Gyroscope (광섬유 자이로스코프의 위상추적 신호처리 분석)

  • Yeh, Y.H.;Cho, S.M.;Kim, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.95-105
    • /
    • 1997
  • A new open-loop signal processing technique of digital phase tracking is known to have a Potential to solve the problems in the open-loop processor such as limited dynamic range, dependence on the optical intensity fluctuations, and dependence on gain fluctuations of signal path. But new problems with digital phase tracking must be solved before it can be a useful signal processing method. In this paper, barriers to the success of the digital phase tracking such as harmonics content, phase difference, amplitude variations of the phase modulation(PM) signal, bandwidth limit of the signal path, and the implementation of the mixer, are pointed out and their effects on the performance of the signal processor are analyzed to calculate the requirements of the signal processor for $1{\mu}rad$-grade FOG.

  • PDF

A Disposable Grating-Integrated Multi-channel SPR Sensor Chip for Detection of Biomolecule (회절격자가 집적된 일회용 다중채널 SPR 생체분자 검출 칩)

  • Jin, Young-Hyun;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.147-154
    • /
    • 2009
  • This paper presents a grating~integrated SPR (Surface Plasmon Resonance) sensor chip for simple and inexpensive biomolecule detection. The grating-integrated SPR sensor chip has two sensing channels having a nano grating for SPR coupling. An external mirror is used for multi channel SPR sensing. The present sensor chip replaces bulky and expensive optical components, such as fiber-optic switches or special shaped prisms, resulting in a simple and inexpensive wavelength modulated multi-channel SPR sensing system. We fabricate a SPR sensor chip integrated with 835 nm-pitch gratings by a micromolding technique to reduce the fabrication cost. In the experimental characterization, the refractive index sensitivity of each sensing channel is measured as $321.8{\pm}8.1nm$/RI and $514.3{\pm}8.lnm$/RI, respectively. 0.5uM of the target biomolecule (streptavidin) was detected by a $1.13{\pm}0.16nm$ shift of the SPR dip in the 10%-biotinylated sample channel, while the SPR dip in the reference channel for environmental perturbation monitoring remained at the same position. From the experimental results, multi-channel biomolecule detection capability of the present grating-integrated SPR sensor chip has been verified. On the basis of the preliminary experiments, we successfully measured the binding reaction rate for the $2\;nM{\sim}200\;nM$ monoclonal-antibiotin, thus verifying biomolecule concentration detectability of the present SPR sensor chip. The binding reaction rates measured from the present SPR sensor chip agredd well with those from a commercialized SPR sensor.

Terahertz Characteristics of InGaAs/InAlAs MQW with Different Excitation Laser Source

  • Park, Dong-U;No, Sam-Gyu;Ji, Yeong-Bin;O, Seung-Jae;Seo, Jin-Seok;Jeon, Tae-In;Kim, Jin-Su;Kim, Jong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.300.2-300.2
    • /
    • 2014
  • 테라헤르쯔(terahertz : THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지(meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한(low-temperature grown : LT) InGaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 LT-InGaAs:Be/InAlAs multi quantum well (MQW)를 well과 barrier를 가각 $10{\mu}m$ 씩 100주기 성장을 하였고 Ti와 Au를 각각 30, $200{\mu}m$로 dipole antenna를 제작 하였다. 이 때 Ti:sapphire femto-pulse laser (30 fs/90 MHz)를 excitation source로 사용하였을 때 9000 pA로 LT-InGaAs epilayer (180 pA)보다 50배 이상 큰 전류 신호를 얻을 수 있었다. THz 발생과 검출을 초소형, 초경량, 고효율로 하기 위해서는 fiber-optic를 이용해야 하는데 이때 분산과 산란 손실이 가장 적은 1550 nm 대역에서 많은 연구가 이루어 졌다. 780, 1560 nm의 mode-locking laser (90 fs/100 MHz)를 사용하여 현재 많이 이용되고 있는 Ti:sapphire femto-pulse laser와 비교하여 THz 특성 변화를 확인하는 연구를 진행 하고 있다.

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Demonstration of the Usefulness of Optical Coherence Tomography in Imaging a Mouse Tail Model of Lymphedema

  • Kim, Hui Dong;Kim, Dong Kyu;Chae, Yu-Gyeong;Park, Seok Gyo;Kim, Ghi Chan;Jeong, Ho Joong;Sim, Young-Joo;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.132-137
    • /
    • 2017
  • To investigate the usefulness of optical coherence tomography (OCT) for imaging lymphedema, we directly compared it to other histological methods in a mouse model of lymphedema. We performed detailed imaging of the lymphedema lesion on a mouse tail. We imaged the mouse tail in vivo with OCT and created histopathological samples. We constructed a spectrometer-based OCT system using a fiber-optic Michelson interferometer. The light was directed to 50:50 couplers that split the light into reference and sample arms. Backscattered light from a reference mirror and the sample produced an interference fringe. An OCT image of the lymphedema model revealed an inflammatory reaction of the skin that was accompanied by edema, leading to an increase in the light attenuation in the dermal and subcutaneous layers. Similar to OCT image findings, histological biopsy showed an inflammatory response that involved edema, increased neutrophils in epidermis and subdermis, and lymphatic microvascular dilatation. Furthermore, the lymphedema model showed an increase in thickness of the dermis in both diagnostic studies. In the mouse tail model of lymphedema, OCT imaging showed very similar results to other histological examinations. OCT provides a quick and useful diagnostic imaging technique for lymphedema and is a valuable addition or complement to other noninvasive imaging tools.

Design and Performance Analysis of Satellite Terminal Management Protocol in KMILSATCOM (군 위성통신체계 위성단말관리 프로토콜 설계 및 성능분석)

  • Lee, Jong-Seong;Choe, Hyeong-Seok;Hwang, In-Gwan
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.1
    • /
    • pp.14-20
    • /
    • 2007
  • The Korean Military Satellite Communication System (KMILSATCOM) is composed of military payload of KOREASAT 5 and military satellite terminals. The military satellite terminals communicate with each other in satellite service area. The satellite terminal management system is developed for centralized management of satellite terminals and communications link. The satellite terminal management system dose not use terrestrial networks (i.e. Fiber optic, Microwave) for management because the KMILSATCOM is system for emergency (i.e. war time) and the satellite terminals has to move to operational area, so the management link must use satellite link. The management link is composed of 1 to N communication scheme for one manager and multiple terminals. This paper describes the satellite terminal management protocol architecture and the performance of the protocol of the KMILSATCOM system.

  • PDF

Application of Combined-Type Sensors for the Behavioral Measurement of Concrete Beams (콘크리트 보의 거동 측정을 위한 조합형 센서의 활용)

  • Kim, Yun-Tae;Kim, Sang-Chel
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.454-461
    • /
    • 2003
  • This study addressed a procedure to carry out an experimental study on a behavior of simple and continuous concrete beams. For this purpose, sample concrete beams were fabricated and sensors for the measurement of strains and deflections were attached both on the surface of the beams and inside them. Two types of sensors were used to measure strains associated with loading: electric resistance strain sensors and fiber optic sensors. Displacement gauges were also attached on the bottoms of beams to investigate the behavior of beams more rationally. The behavior of the beams was then evaluated throughout the results measured from different sensors while they were subject to steady loading up to failure. From results of this study, it was found that concurrent use of sensors and displacement gauges is helpful in investigating the behavior of concrete beams more effectively. Especially, combined-type strain sensors specifically fabricated in this experiment were found not to be affected by the occurrence of cracks so significantly and to be very effective in monitoring strains of concrete structure. It was also observed that beams show nonlinear force-displacement relationship and reinforcing bars take charge of resisting the external force once cracks occur in concrete beams.

A clinical study of the power control of Nd : YAG laser for painless irradiation on intraoral soft tissues (구강내 연조직에 대한 무통적조사를 위한 Nd:YAG laser의 출력조절에 관한 임상적 연구)

  • Han, Sang-Hak;Kim, Hyun-Sub;Lim, Kee-Jung;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.2
    • /
    • pp.522-530
    • /
    • 1996
  • Most dentists are very interested in laser therapy on the intraoral soft tissue lesions because they want to accomplish the analgesic and aseptic surgery with little or no bleeding. In order to determine the difference of pain threshold according to different gingival tissues with or without inflammation, 25 patients with inflammatory periodontal disease and 10 volunteers with good general and oral health were selected as the inflamed group and the normal group, respectively. Interdental papilla, marginal gingiva, attached gingiva, and alveolar mucosa were irradiated by the contact delivery($300{\mu]m$ fiber optic, for 5 seconds) of a pulsed Nd:YAG laser(EN.EL.EN06O, Italy). And the laser power was gradually increased from 0.5W by the increment of 0.1W. The highest laser power was recorded as the first painful power when the painful gesture was recognized at first. The difference of the first painful power of laser according to different gingival tissues with or without inflammation was statistically analyzed by paired t-test in MICROSTAT program. Following results were obtained: 1. In the comparison related with the inflammation, the first painful power was significantly lower in the inflamed group than in the normal group, regardless of interdental papilla and marginal gingiva(p<0.05). 2. In the comparison related with the tissue structure, the first painful. power was significantly lower in alveolar mucosa than in attached gingiva(p<0.05). The results suggest that, for the painless therapy by a pulsed-Nd:YAG laser irradiation, the laser surgery over 2.0W of power should be necessarily accomplished under the local anethesia, and the local anesthesia should be considered according to the degree of inflammation, the tissue structure, and the purpose of laser therapy.

  • PDF

Microsurgery of the Laryngeal Lesions (Suspenison Laryngoscope에 의한 후두병 변의 진단 및 치험례)

  • 장인원;이종원;권영춘;정규화;정종진
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.7.1-7
    • /
    • 1978
  • The microsurgery of the laryngeal lesions was introduced by Kleinsasser in 1965. This has been utilized for diagnosis, surgical management and education of the laryngeal lesions. The laryngomic-roscopic technique appear to be useful in the evaluation of the lesions which may be precancerous, since minor degrees of epithelial thickening and alterations in the pattern of fine vessels beneath the epithelium may be observed with greater clarity. With suspension laryngoscopy, the authors experienced 11 cases of the laryngeal lesions: polyp (4 cases), web formation between false cords and true cords (1), papilloma (4), laryngeal trauma (1), and squamous cell carcinoma (1).

  • PDF