• Title/Summary/Keyword: Fiber angle

Search Result 678, Processing Time 0.02 seconds

Indirect measure of shear strength parameters of fiber-reinforced sandy soil using laboratory tests and intelligent systems

  • Armaghani, Danial Jahed;Mirzaei, Fatemeh;Toghroli, Ali;Shariati, Ali
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.397-414
    • /
    • 2020
  • In this paper, practical predictive models for soil shear strength parameters are proposed. As cohesion and internal friction angle are of essential shear strength parameters in any geotechnical studies, we try to predict them via artificial neural network (ANN) and neuro-imperialism approaches. The proposed models was based on the result of a series of consolidated undrained triaxial tests were conducted on reinforced sandy soil. The experimental program surveys the increase in internal friction angle of sandy soil due to addition of polypropylene fibers with different lengths and percentages. According to the result of the experimental study, the most important parameters impact on internal friction angle i.e., fiber percentage, fiber length, deviator stress, and pore water pressure were selected as predictive model inputs. The inputs were used to construct several ANN and neuro-imperialism models and a series of statistical indices were calculated to evaluate the prediction accuracy of the developed models. Both simulation results and the values of computed indices confirm that the newly-proposed neuro-imperialism model performs noticeably better comparing to the proposed ANN model. While neuro-imperialism model has training and test error values of 0.068 and 0.094, respectively, ANN model give error values of 0.083 for training sets and 0.26 for testing sets. Therefore, the neuro-imperialism can provide a new applicable model to effectively predict the internal friction angle of fiber-reinforced sandy soil.

A Study on the Current Measurement Using Spun Fiber (Spun 광섬유를 이용한 전류 측정에 관한 연구)

  • Kwon, Won-Hyun;Jeon, Suk-Hee;Kim, Young-Soo;Kim, Yo-Hee;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.10
    • /
    • pp.1158-1165
    • /
    • 1988
  • In this paper, the polarization properties of spun fiber due to intrinsic birefringence and magneto-optic effects are theoretically analyzed and experimented. The degree of polarization which indicates the intrinsic birefrigence is measured over 0.818, and the variation of output polarization angle with input polarization angle is measured within 9$^{\circ}$. Compared with single mode fiber, spun fiber is found to have very excellent polarization-maintaining property. Implemented current measurement system using spun fiber can linearly measure the magnetic field up to 20,000 A/m generated by solenoid.

  • PDF

Fabrication and characterization of aligned crossply PHBV fibrous mat

  • Kim, Yang-Hee;Yang, Hun-Mo;Song, Ho-Yeon;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.44.1-44.1
    • /
    • 2010
  • poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) is a bacterially derived copolymer produced by fermentation. PHBV has been attractive because of its potential environmental, pharmaceutical and biomedical applications. Recently, the electrospinning technique has been used to fabricate fibrous mat for biomedical applications such as artificial blood vessel, drug release and scaffolds, because this method is simple and easy to get ultrafine polymer fibers. Depending on speed of rotation drum collector, fiber structure was different. In this work, PHBV fiber was aligned by electrospinnning machine. Furthermore, alignment of PHBV fiber mats was given angle such as $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$. The morphology of each aligned PHBV fiber mat was observed by SEM technique. The mechanical property was evaluated depending on alignment angle. Especially, cell attachment ability depending on alignment of PHBV fiber mats was carried out using MG- 63 osteoblast like cells.

  • PDF

Buckling Strength Analysis of Stiffened Composite Plates for the Optimum Laminate Structure (최적 적층구조를 위한 보강된 복합적층판의 좌굴강도 해석)

  • H.R.,Kim;J.W.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 1989
  • The optimun laminated composition of the stiffened composite plates is studied from the view point of buckling strength. The finite element method is applied to the buckling analysis of the composite plates taking into account the effect of shear deformation through the plate thickness. The stiffened plate model is discretized using plate thickness and symmetrically stacked. Parametric study is carried out for the selection of the optimum laminate structure; optimum fiber angle sequence through the thickness. Laminate structure of $[-45^{\circ}/45^{\circ}/90^{\circ}/0^{\circ}]$, is found to give the best buckling strength. For the case of that layer number is more than eight, best result is obtained when layers of the same fiber angle are put together, leaving the laminate has the same fiber angle sequence as a whole.

  • PDF

Electromagnetic Interference Shielding of Carbon Fibers-Reinforced Composites (탄소섬유강화 복합재료의 전자파 차폐특성)

  • 심환보;서민강;박수진
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.860-868
    • /
    • 2000
  • In this work, the electro-magnetic interference (EMI) characteristics of PAN-based carbon fibers-reinforced composites are investigated with difference to manufactural parameters, i.e., fiber grade, fiber orientation angle, and laminating method. As a result, EMI shielding effectiveness (SE) of the composites greatly depends on a fiber orientation in composite angle. Especially, the fiber grade affects SE of composites in case of orientation angle of 0$^{\circ}$. Then the SE become greater as the change of electric character according to the arrangement directions, i.e., electrical anisotropy in the same constituent materials. This is due to the skin effect which is represented in the surface of electro-magnetic wave in high-frequency range. In all cases according to lamination methods, the composites represents SE of 83~98% over. Whereas, in symmetric and unsymmetric laminate structures, the SE decreases slightly as the laminate angles of composites increases. On the contrary. the repeating laminates structure shows the opposite tendency. Especially, 90$^{\circ}$ repeating laminate structure shows the SE more than 90% over the measuring frequency.

  • PDF

The Optimization of Optical Current Transformer owing to Incident Polarization (입사편광에 따른 광섬유형 광 CT의 최적화)

  • Kim Duck-Lae;Kim Byung-Tai
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.407-413
    • /
    • 2005
  • The optical current transformer was developed for 170 kV GIS using optical fiber. The sensor optimized on the optical CT was wound 3 turns and twisted 4 times per a turn at the pipe with a diameter of 130 m. To optimize the optical CT, the output signal was measured according to the setting angle of polarizer and analyzer, The asymmetry and distortion of the output signals were improved when the parallel polarized light was incident to the fiber sensor and under the angle of analyzer was $45^{o}$. The measurement error for the linearity was only $\pm{0.42}\;\%$ to 1,000 A in the case of reflection type.

A Study on the Surface Degradation Properties of Epoxy / Glass fiber Treated with Ultraviolet Rays (자외선 처리된 Epoxy/Glass Fiber의 표면 열화 특성에 관한 연구)

  • Lee, Baek-Su;Lee, Deok-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.86-91
    • /
    • 1999
  • In order to analyse the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to the wavelength of ultraviolet rays and evaluated by comparing contact angle, surface resistivity, surface potential decay, and ESCA spectrum respectively. As irradiation energy are increased, the surface properties were steeply decreased in the range of 300[nm]. But the measured values within the scope of400[nm]∼440[nm] showed a increase as compared with the untreated ones. Also, fromthe result of ESCA spectrum, it was confirmed plenty of oxygen groups on the spot showing the maximum decrease of surface properties and the existence of ether groups on the surface of coloring phase. We can conclude that the degradation phenomena on the surface of epoxy composites are dominated by the induction of ester and carboxyl groups.

  • PDF

Response of fiber reinforced plastic chimneys to wind loads

  • Awad, A.S.;El Damatty, A.A.;Vickery, B.J.
    • Wind and Structures
    • /
    • v.3 no.2
    • /
    • pp.83-96
    • /
    • 2000
  • Due to their high corrosion and chemical resistance, fiber reinforced plastics (FRP) are becoming widely used as the main structural material for industrial chimneys. However, no national code currently exists for the design of such type of chimneys. The purpose of this study is to investigate analytically the response of FRP chimneys to wind loads. The classical lamination theory is used to substitute the angle-ply laminate of a FRP chimney with an equivalent orthotropic material that provides the same stiffness. Dynamic wind loads are applied to the equivalent chimney to evaluate its response to both along and across wind loads. A parametric study is then conducted to identify the material and geometric parameters affecting the response of FRP chimneys to wind loads. Unlike the across-wind response, the along-wind tip deflection is found to be highly dependent on the angle of orientation of the fibers. In general, the analysis shows that FRP chimneys are very vulnerable to across-wind oscillations resulting from the vortex shedding phenomenon.

A Study on the Energy Absorption Characteristics and Fracture Mode of CFRP Laminate Members under Axial Compression (축압축을 받는 CFRP 적층부재의 에너지흡수특성과 파괴모드에 관한 연구)

  • 김정호;정회범;전형주
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.7-12
    • /
    • 2002
  • The object of this paper is to investigate collapse characteristics of CF/Epoxy(Carbon Fiber/Epoxy resin) composite tubes on the change of interlaminar number and fiber orientation angle of outer and to evaluate reappearance of collapse characteristics on the change of tension strength of fibers under static and impact axial compression loads. When a CF/Epoxy composite tube is mushed, static/impact energy is consumed by friction between the loading plate and the splayed fiends of the tube, by fracture of the fibers, matrix and their interface. In general, CF/Epoxy tube with 6 interlaminar number(C-type) absorbed more energy than other tubes(A, B, D-types). The maximum collapse load seemed to increase as the interlaminar number of such tubes increases. The collapse mode depended upon orientation angle of outer of CF/Epoxy tubes and loading status(static/impact). Typical collapse modes of CF/Epoxy tubes are wedge collapse mode, splaying collapse mode and fragmentation collapse mode. The wedge collapse mode was shorn in case of CF/Epoxy tubes with 0$^{\circ}$ orientation angle of outer under static and impact loadings. The splaying collapse mode was shown in only case of CF/Epoxy tubes with 90$^{\circ}$ orientation angie or outer under static loadings, however in impact tests those were collapsed in fragmentation mode. So that CF/Epoxy tube with 6 interlaminar number and 90$^{\circ}$ outer orientation angle presented to the optimal collapse characteristics.

A Study on the Impact and Vibration acting on the Laminated Composite Honeycomb Core Type Sandwich Plate Structure (복합적층 하니콤 코어형 샌드위치 판구조물에 미치는 충격과 진동에 관한 연구)

  • Hong, Do-Kwan;Seo, Jin;Ahn, Chan-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.616-622
    • /
    • 2001
  • In this paper, we analyzed the laminated composite sandwich plate structure of honeycomb core with changing values of the designing parameters. As a result, in designing parameters of that, the more height and thickness of the laminated composite plate's core, the more increase of natural frequency. The laminated angle has the maximum value when the plate of honeycomb core is join to opposite direction. This paper shows that the natural frequency of CFRP is higher than that of GFRP, and also impact strength marks maximum value in case of antisymmetry than symmetry of core. Also it shows that the mode shapes are various along with the angle-ply of laminated composite plate.

  • PDF