• Title/Summary/Keyword: Fenton Process

Search Result 140, Processing Time 0.019 seconds

A comparative study on applicability of nano-sized iron(II, III) oxide in ultrasonicated Fenton process

  • Sahinkaya, Serkan;Yakut, Sennur Merve
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • Fenton process is one of the most effective advanced oxidation processes for the removal of pollutants from wastewater. In this study, while ferrous iron was used in conventional Fenton process (CFP); nano-sized iron(II, III) oxide was experienced in modified Fenton process (MFP) as a new catalyst alternative. In order to enhance their oxidation efficiencies, both CFP and MFP were combined with ultrasonication at 53 kHz fixed frequency. Thus, the influences of both catalyst iron species and ultrasonication on color and chemical oxygen demand (COD) removals from synthetic textile wastewater including Maxilon Red GRL 200% dyestuff were investigated experimentally. While the COD and color removal rates were found as 72.5% and 69.7% via CFP; they were 87% and 75.8% by ultrasonicated CFP, respectively. The color and COD removals were 40.6% and 64.8% via MFP, and 49.9 and 73.1% by ultrasonicated MFP, respectively. Therefore, it was found that the simultaneously usage of ultrasonication with CFP and MFP was improved the COD and color removal efficiencies and oxidation rates even at lower H2O2 dosages, compared to individual CFP and MFP. Moreover, the color and COD removal kinetics were also modelled mathematically and compared in the study.

A Role of Dissolved Iron ion in Combined Fenton Reaction for Treatment of TNT Contaminated Soil (오염토양처리를 위한 혼합 Fenton 공정에서 용존 철이온이 오염산화처리에 미치는 역할에 관한 연구)

  • Seo, Seung-Won;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.76-82
    • /
    • 2006
  • Fenton's reaction are difficult to apply in the field due to the low pH requirements for the reaction and the loss of reactivity caused by the precipitation of iron (II) at neutral pH. Moreover, Fenton-like reactions using iron mineral instead of injection of iron ion as a catalyst are operated to get high removal result at low pH. Because hydroxyl radical can generate at the surface of iron mineral, there are competition with a lot of hydroxide at around neutral pH. On the other side, to operate Fenton's reaction series at neutral pH, modified Fenton reaction is suggested. The complexes, composed by iron ions (ferrous ion or ferric ion)-chelating agent, could be acted as a catalyst and presented in the solution at neutral pH. However, modified Fenton reaction requires a lot of hydrogen peroxide. Accordingly, the purpose of this experiment was to effectively combine Fenton-like reaction and modified Fenton reaction for extending application of Fenton's reaction. i.e., injecting chelating agents in Fenton-like reaction at around neutral pH is increasing the concentration of dissolved iron ion and highly promoting the oxidation effect. 2,4,6-trinitrotoluene (TNT) was used as a probe compound for comparing reaction efficiencies in this study. If the concentration of dissolved iron ion in combined Fenton process were existed more than 0.1 mM, the total TNT removal were increased. Magnetite-NTA system showed the best TNT removal (76%) and Magnetite-EDTA system indicated about 56% of TNT removal. The results of these experiments proved more promoted 40-60% of TNT removal than Fenton-like reaction's.

The remediation of contaminated kaolinite by phenanthrene using Electrokinetic-Fenton process (Electrokinetic-Fenton 공정에 의한 Phenanthrene으로 오염된 카올린의 정화)

  • 김정환;김익현;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.593-596
    • /
    • 2002
  • This study examined the feasibility of Electrokinetic-Fenton process for remediation of contaminated kaolinite by phenanthrene. The test using 7% H$_2$O$_2$as anode purging solution indicated the higher electrical current and electroosmotic flow than the test using 3.5% H$_2$O$_2$. And distribution in the soil of H$_2$O$_2$concentration showed the higher value of the former than the latter. Furthermore, the test using 7% H$_2$O$_2$and 0.01N H$_2$SO$_4$was the highest electrical current and electroosmotic flow and H$_2$O$_2$was effectively introduced to the cathode region. As it turned out, the treatment effect of phenanthrene was improved in compare with the other tests.

  • PDF

Treatment Study of Textile Wastewater by Fenton's Oxidation (펜톤 산화반응에 의한 염색폐수처리 연구)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.20-25
    • /
    • 2000
  • The wastewater treatment for the purpose of water-recycling was performed using Fenton's & ozone's methods. These methods were used to increase the treatment efficiency of textile wastewater and to search for the optimal operating conditions. The optimal conditions by Fenton process were determined so that input amounts of $FeSO_4{\cdot}7H_2O$ and $H_2O_2$ were $7.2mM/{\;}{\ell}$ and $49.0m/{\;}{\ell}$ respectively, treatment by ozone process had 92% removal efficiency at ozone concentration of 9.73g/min and $130mM/{\;}{\ell}$ of $H_2O_2$.

  • PDF

Removal of Methyl tert-Butyl Ether (MTBE) by Modified Fenton Process for in-situ Remediation (Methyl tert-Butyl Ether(MTBE)의 in-situ Remediation을 위한 Modified Fenton Process에 관한 연구)

  • Chung, Young-Wook;Seo, Seung-Won;Kim, Min-Kyoung;Lee, Jong-Yeol;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.2
    • /
    • pp.27-36
    • /
    • 2007
  • A recent study showed that MTBE can be degraded by Fenton's Reagent (FR). The treatment of MTBE with FR, however, has a definite limitation of extremely low pH requirement (optimum pH $3{\sim}4$) that makes the process impracticable under neutral pH condition on which the ferrous ion precipitate forming salt with hydroxyl anion, which result in the diminishment of the Fenton reaction and incompatible with biological treatment. Consequently, this process using only FR is not suitable for in-situ remediation of MTBE. In order to overcome this limitation, modified Fenton process using NTA, oxalate, and acetate as chelating reagents was introduced into this study. Modified Fenton reaction, available at near neutral pH, has been researched for the purpose of obtaining high performance of oxidation efficiency with stabilized ferrous or ferric ion by chelating agent. In the MTBE degradation experiment with modified Fenton reaction, it was observed that this reaction was influenced by some factors such as concentrations of ferric ion, hydrogen peroxide, and each chelating agent and pH. Six potential chelators including oxalate, succinate, acetate, citrate, NTA, and EDTA were tested to identify an appropriate chelator. Among them, oxalate, acetate, and NTA were selected based on their remediation efficiency and biodegradability of each chelator. Using NTA, the best result was obtained, showing more than 99.9% of MTBE degradation after 30 min at pH 7; the initial concentration of hydrogen peroxide, NTA, and ferric ion were 1470 mM, 6 mM, and 2 mM, respectively. Under the same experimental condition, the removal of MTBE using oxalate and acetate were 91.3% and 75.8%, respectively. Optimum concentration of iron ion were 3 mM using oxalate which showed the greatest removal efficiency. In case of acetate, $[MTBE]_0$ decreased gradually when concentration of iron ion increased above 5 mM. In this research, it was showed that modified Fenton reaction is proper for in-situ remediation of MTBE with great efficiency and the application of chelatimg agents, such as NTA, was able to make the ferric ion stable even at near neutral pH. In consequence, the outcomes of this study clearly showed that the modified Fenton process successfully coped with the limitation of the low pH requirement. Furthermore, the introduction of low molecular weight organic acids makes the process more available since these compounds have distinguishable biodegradability and it may be able to use natural iron mineral as catalyst for in situ remediation, so as to produce hydroxyl radical without the additional injection of ferric ion.

Dye Decomposition in Seawater using Electro-Fenton Reaction (전기-펜톤 반응을 이용한 해수 중의 염료 분해)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.29 no.4
    • /
    • pp.383-393
    • /
    • 2020
  • To increase electrolysis performance, the applicability of seawater to the iron-fed electro-Fenton process was considered. Three kinds of graphite electrodes (activated carbon fiber-ACF, carbon felt, graphite) and dimensionally stable anode (DSA) electrode were used to select a cathode having excellent hydrogen peroxide generation and organic decomposition ability. The concentration of hydrogen peroxide produced by ACF was 11.2 mg/L and those of DSA, graphite, and carbon felt cathodes were 12.9 ~ 13.9 mg/L. In consideration of durability, the DSA electrode was selected as the cathode. The optimum current density was found to be 0.11 A/㎠, the optimal Fe2+ dose was 10 mg/L, and the optimal ratio of Fe2+ dose and hydrogen peroxide was determined to be 1:1. The optimum air supply for hydrogen peroxide production and Rhodamine B (RhB) degradation was determined to be 1 L/min. The electro-Fenton process of adding iron salt to the electrolysis reaction may be shown to be more advantageous for RhB degradation than when using iron electrode to produce hydrogen peroxide and iron ion, or electro-Fenton reaction with DSA electrode after generating iron ions using an iron electrode.

Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition (펜톤산화에 따른 복합폐수의 처리효율연구)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.

Degradation Characteristics of Non-biodegradable Matters using Pre-Coagulation and Fenton Oxidation Process in Livestock Wastewater (전응집 및 Fenton 산화공정을 이용한 축산폐수의 난분해성물질 제거특성에 관한 연구)

  • Cho, Chang-Woo;Kim, Boung-Young;Chae, Soo-Choen;Kim, Sun-Ae;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.66-73
    • /
    • 2006
  • The purpose of this study was done to evaluate degradation characteristics of non-biodegradable organic matters including aromatic compounds in livestock wastewater using CFZ process. The CFZ process is consisted of coagulation/sedimentation, Fenton oxidation and zeolite adsoption process. degradation charateristics of each treatment water including livestock wastewater were analyzed by UV scanning, FT-IR and GC/MS. After coagulation/sedimentation process as 1st treatment, non-biodegradable matters remained after 1st treatment were removed by using OH radical produced in Fenton oxidation process. As a result of treatment using these processes, NBDCOD removal efficiency was over 90%. Increase of $E_2/E_3$ ratio (absorbance at 250 and 365 nm) in each treatment water means that aromaticity of livestock wastewater decreased. In case of GC/MS, most aromatics or polynuclear aromatics like benzene, phenol and scatol in livestock wastewater almost wasn't detected after oxidation using OH radical.

Degradation of energetic compounds using an integrated zero-valent iron-Fenton process

  • Oh Seok-Young;Kim Byung J.;Chiu Pei C.;Cha Daniel K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.493-500
    • /
    • 2003
  • The effect of reductive treatment with elemental iron on the extent of mineralization by Fenton oxidation was studied for the explosive 2,4,6-trinitrotoluene (TNT) and hexahydro-l,3,5-trinitro-l,3,5-triazine (RDX) using a completely-stirred tank reactor (CSTR). The results support the hypothesis that TNT and RDX are reduced with elemental iron to products that are oxidized more rapidly and completely by Fenton's reagent. Iron pretreatment enhanced the extent of TOC removal by approximately $20\%\;and\;60\%$ for TNT and RDX, respectively. Complete TOC removal was achieved for TNT and RDX solutions with iron pretreatment under optimal conditions. On the other hand, without iron pretreatment, complete mineralization of TNT and RDX solutions were not achieved even with much higher $H_2O_2$ and $Fe^{2+}$ concentrations. The bench-scale iron treatment-Fenton oxidation integrated system showed more than $95\%$ TOC removal for TNT and RDX solutions under optimal conditions. The proposed zero-valent iron-Fenton process was evaluated with pink water from the Iowa Army ammunition plant. Results from batch and column experiments show that TNT, RDX, and octahydro-l,3,5,7-tetranitro-l,3,5,7-tetrazocine (HMX) were completely removed from the pink water and that triaminotoluene (TAT) and ${NH_4}^+$ were recovered as products in reduction with zero-valent iron. By using an integrated system, $83.3\pm4.2\%$ of TOC was removed in a CSTR with 10 mM of $Fe^{2+}$ and 50 mM of $H_2O_2$. These results suggest that the reduction products of TNT and RDX are more rapidly and completely mineralized by Fenton oxidation and that a sequential iron treatment-Fenton oxidation process may be a viable technology for pink water treatment.

  • PDF

Methodology Development for the Reuse of Sludge Generated from Fenton's Oxidation Process (펜톤산화 공정에서 발생하는 슬러지의 재활용 방안)

  • Koo, Tai-Wan;Cho, Soon-Haing;Choi, Young-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1083-1091
    • /
    • 2000
  • The objective of this study is to develop effective and economical treatment processes for the removal of non-biodegradable organics by reusing the sludge generated from Fenton's Oxidation Process. It was found that about 50% of coagulants and 50% of catalyst can be reduced by reusing the sludge generated from Fenton's Oxidation Process. It was also found that the amount of sludge generation can be reduced in coagulation process and Fenton's Oxidation Process. From the results of bench-scale test, it was found that the average removal efficiency increased to 8.5% and the amount of sludge generation was reduced up to 35% by reusing the sludge as coagulant. The average organic removal efficiency increased to 5.3% and the amount of sludge generation was reduced up to 14% by reusing the sludge as catalyst in Fenton's Oxidation. It can be concluded that the reuse of sludge generated from Fenton's Oxidation Process would be reduced cost of chemical consumption and Fenton's sludge treatment.

  • PDF