Fenton난s Reagent Oxidation of Refractory Organics in Petrochemical Plant Effluent (석유화학공장 방류수내 난분해성 유기물의 Fenton 산화처리)

  • Lee, Kyu-Hoon;Jung, Dae-Young;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.51-59
    • /
    • 1996
  • The purpose of this study was to evaluate the partial oxidation of the biological treatment plant effluents using Fenton's reagent as a pretreatment step prior to a tertiary biological oxidation of these effluents. Fenton's reagent was evaluated as a pretreatment process for inhibitory or refractory organics. Based on the Fenton oxidation system, the petrochemical wastewater treatment plant effluent was shown to have significant improvement in toxicity after oxidation with hydrogen peroxide. For example, at ranee of 42 ∼ 184 mg/L COD of petrochemical plant effluents, the COD removal efficiencies were from 38.2% to 60.1% after reaction with hydrogen peroxide 200 mg/L and Fe2+ 100 mg/L and reaction time was 30 minutes. The total TOC reduction were about 15.8∼22.4% with same test condition and difference between the overall removal rate and BOD/COD ratio after Fenton's oxidation estabilished in the biodegradation and otherwise meets the discharge standard or reuse for cooling tower make-up water.

  • PDF

EFFECTS OF REACTION TIME AND pH ON FENTON'S BATCH PROCESS FOR THE TREATMENT OF LEACHATE

  • Choi, Heung-Jin;Kim, Il-Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.169-187
    • /
    • 2002
  • The effects of important parameters such as reaction time and pH on the Fenton's process were evaluated using a batch reactor. It was proven that organic materials and heavy metals in leachate could be successfully removed by Fenton's reagent. Favorable operation conditions were investigated. It was observed that the reaction between ferrous iron and hydrogen peroxide with the production of hydroxyl radical was almost complete in 10 minutes. That is, the oxidation of organic materials by Fenton's reagent was so fast that it was complete in 30 minutes with batch experiments. With the formation of carbonic acid, pH of the batch reactor decreased to favorable acidic conditions without acid addition. The oxidation of organic materials in the leachate showed a pH dependence and was most efficient in the pH range of 2-3.

Degradation of 2,3-dichlorophenol by a Photo-Fenton Process with Continuous Pump-Feeding of Hydrogen Peroxide (동력펌프주입식 광펜톤시스템에 의한 2,3-디염화페놀 분해특성 연구)

  • Kim, Il-Kyu
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.84-90
    • /
    • 2014
  • The degradation of 2,3-dichlorophenol(2,3-diCP) by various advanced oxidation systems with continuous feeding of hydrogen peroxide including the ultraviolet/hydrogen peroxide, the Fenton and the photo-Fenton process has been conducted. The highest removal efficiency for 2,3-diCP in the aqueous phase was obtained by the photo-Fenton process among the advanced oxidation systems. In the photo-Fenton process, The removal efficiency of 2,3-diCP decreased with increasing pH in the range of 3 to 6, and it decreased with increasing initial concentration. As the intermediates of 2,3-diCP by photo-fenton reaction, 3,4-chlorocatechol and 2,3-dichlorohydroquinone were detected, thus the degradation pathways were proposed.

Study on the Application of the Fenton Oxidation Method for Remediation of Small-scale Oil-contaminated Ballasts on Railroad Track (선로 내 소규모 유류오염도상자갈 정화를 위한 펜톤산화법의 적용성 연구)

  • Kwon, Tae-Soon;Lee, Jae-Young;Kim, Hee-Man;Jung, Woo-Sung;Kim, Jong-Heun
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.5
    • /
    • pp.466-470
    • /
    • 2015
  • In this study, Fenton oxidation was applied to railroad track ballasts contaminated with small amounts of oil. In order to perform the experiment on Fenton oxidation, petroleum contaminated ballast was collected from the railroad track and experiments on major factors of the remediation process were implemented in the laboratory. Then, the feasibility of insitu Fenton oxidation was investigated for the railroad track that was partially contaminated with oil. As a result, the residual TPH concentration of ballast was reduced to about 1,000 mg/kg-ballast in laboratory experiments using 0.1 mol Fe/L $H_2O_2$. Due to the drainage structure of the track bed, a considerable amount of $H_2O_2$ was released below the ballast without the sufficient reaction with the contaminated ballast; therefore, additional studies are necessary for the effective field application of Fenton oxidation.

Evaluation on Enhanced Biodegradability in Landfill Leachate by Fenton Oxidation (Fenton 산화법에 의한 매립장 침출수의 생물 분해성 증진에 관한 평가)

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.250-256
    • /
    • 2005
  • This study was aimed to investigate treatment feasibility of leachate from D landfill that is located in gyr대ungbuk. From the analytical results of leachate, organic and nonbiodegradable matters were contained in high concentration. Thus chemical treatment was introduced to degrade nonbiodegradable matters in pre or post biological process. Two types of Fenton oxidation were adapted in this study. The first one is pre treatment process before biological treatment. The second one is post treatment process after biological treatment. The optimal conditions of both treatment methods were investigated as follows. In case of pre treatment process, the optimal conditions appeared in $Fe^{+2}/H_2O_2$(mmol/mmol): 0.1, $H_2O_2/CODcr$(mg/mg): 27.0, pH: 3 and reaction time: 2hrs. On the other hand, in case of post treatment process, the optimal conditions appeared in $Fe^{2+}$(mmol/mmol): 0.14, $H_2O_2/COD_{cr}$(mg/mg): 57.4, pH: 3 and reaction time: 1.25hrs. In the above optimal conditions, high COD removal was obtained in pre and post treatment process. Also it can expect that Fenton oxidation converted nonbiodegradable matters into biodegradable matters.

Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition (펜톤산화에 따른 복합폐수의 처리효율연구)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.

Advanced oxidation technologies for the treatment of nonbiodegradable industrial wastewater (난분해성 산업폐수 처리를 위한 고도산화기술)

  • Kim, Min Sik;Lee, Ki-Myeong;Lee, Changha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.445-462
    • /
    • 2020
  • Industrial wastewater often contains a number of recalcitrant organic contaminants. These contaminants are hardly degradable by biological wastewater treatment processes, which requires a more powerful treatment method based on chemical oxidation. Advanced oxidation technology (AOT) has been extensively studied for the treatment of nonbiodegradable organics in water and wastewater. Among different AOTs developed up to date, ozonation and the Fenton process are the representative technologies that widely used in the field. Based on the traditional ozonation and the Fenton process, several modified processes have been also developed to accelerate the production of reactive radicals. This article reviews the chemistry of ozonation and the Fenton process as well as the cases of application of these two AOTs to industrial wastewater treatment. In addition, research needs to improve the cost efficiency of ozonation and the Fenton process were discussed.

Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation (가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술)

  • Joo, Soobin;Lee, Sangmin;Kim, Hyungjun;Shim, Intae;Kim, Heejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.449-458
    • /
    • 2023
  • As an adsorption technology for dissolved organic matter, the adsorption capacity of granular activated carbon, GAC, can be applied, but activated carbon whose adsorption capacity is significantly reduced by use is inevitably replaced or regenerated. However, due to the economics of replacement cost, thermal regeneration method is used commercially, but high energy cost and loss of activated carbon occur under high temperature conditions above 800℃. In this study, the Sono-Fenton method, a multi-oxidation technology that combines Fenton oxidation and ultrasonic oxidation, was applied to improve the regeneration efficiency of spent GAC used to treat dissolved organic matter in combined sewer overflows (CSOs), and the regeneration efficiency of spent GAC by oxidant and ultrasonic frequency was investigated. In the applied Sono-Fenton treatment, the highest regeneration efficiency of 68.5% was obtained under the regeneration conditions of Fe2+ 10 mmol/L, H2O2 concentration 1,000 mmol/L, ultrasonic treatment time of 120 min, and ultrasonic frequency of 40 kHz. And similar efficiency was also obtained at 750 kHz, while ultrasonic waves of other frequencies had poor regeneration efficiency, and the magnitude of frequency and GAC regeneration efficiency did not show a linear relationship. In the case of continuous operation of the GAC adsorption tower with CSOs prepared by diluting raw sewage, about 700 hours of operation without regeneration was possible, and as a result of applying one Sono-Fenton treatment, 40-70% CODcr removal efficiency was obtained during a total of 1,000 hours of GAC adsorption operation.

Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process (산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향)

  • Kim, Jung Hwan;Na, So Jeong;Park, Joo Yang;Byun, Young Deog
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

A Study on the Efficient Applicability of Fenton Oxidation for the Wastewater Containing Non-biodegradable Organics (생물난분해성 유기물질 함유 폐수처리를 위한 Fenton 산화법의 효율적 적용방안에 관한 연구)

  • Jun, Se Jin;Kim, Mi Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • This research is about wastewater containing non-biodegradable TDI(Toluene Diisocyanate) that is treated by the activated carbon adsorption method. In the case of the Fenton oxidation process being applied to the existing process, optimal pH, reaction time, chemical dosing amount, removal rate, and cost were investigated. A pilot plant test was applied after finding optimal conditions with lab experiments. The optimal conditions were pH 3~5(COD removal rate 84~88%) and reaction time 30min~1hr. In higher $H_2O_2$ dosing amount, COD removal rate was a little higher. But there was little difference in the removal rate according to $FeSO_4{\cdot}7H_2O$ dosing amount. Treatment cost was economical in the case of the Fenton oxidation process being operated earlier than activated carbon adsorption system. But chemical dosing point, chemical mixing effect, chemical dosing amount, removal rate, and the cost of facility and others must be considered in practical process.

  • PDF