• Title/Summary/Keyword: Fecal Coliform

Search Result 176, Processing Time 0.027 seconds

Photoreactivation Study of Wastewater Treatment Effluent Disinfected by UV-disinfection for Water Reuse (용수재이용을 위한 하수처리 유출수의 UV 소독 후 광회복 조사)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.84-93
    • /
    • 2003
  • Photoreactivation of microorganism following UV-disinfection is one of the research topics of interest in assessing the UV-disinfection performance. Apparent photoreactivation was examined under fluorescent lamp and solar radiation as well as in darkness. Total coliform, fecal coliform, and Escherichia coli were used as indicator microorganisms, and their concentration was monitored with time after UV-disinfection. Under the darkness, their initial concentration of 10∼30 MPN/100 mL increased to the level of 100 MPN/100 mL after 24 hours, which implied that part of damaged microorganisms by UV-disinfection might be repairable with time. Under the fluorescent lamp, photoreactivation was more apparent that their concentration increased up to 1,000 MPN/100 mL which might significantly impair the water uses specially in reuse of reclaimed wastewater. However, their concentration further decreased down to below 2 MPN/100 mL under the solar radiation primarily due to additional disinfection by solar radiation rather than photoreactivation. Samples not disinfected by UV-disinfection also demonstrated substantial decrease of their concentration under solar radiation from about 5,000 MPN/100 mL to less than 30 MPN/100 mL in 24 hours. But direct reuse of effluent without disinfection is not recommended because natural decay by solar radiation may take time and be affected by climatic conditions. The result suggests that photoreactivation of pathogenic microorganisms may not be concerned in agricultural reuse of reclaimed wastewater because solar radiation may provide further disinfection after UV-disinfection.

Discharge of the Pollutants from Rice Paddies during the Period of Cultivation (경작기 농경배수에 의한 오염물질의 배출)

  • An, Ik-Sung;Kim, Youngchul;Lee, Dong-Ryul
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.266-273
    • /
    • 2007
  • In this study, discharge of the pollutants from the rice paddies during cultivation and its pattern were investigated. The pH in the returned and rainfall water from ten different paddies was between 6.9 and 7.4, which is not associated with the cultivation time and farming style of individual paddy. TN and TP concentrations were highest in the beginning of first top dressing (fertilization), which indicates that proper top dressing and returned water management is crucial to reduce their discharge loads. In particular, TN concentration was more or less constant until tillering stage. This is thought to be due to the runoff of soil-adsorbed nitrogen and compost. Average SS concentration in the returned and rainfall water was 28 mg/L, and organics was predominantly soluble form, and highest COD 25 mg/L during transplanting, lowest 11.3 mg/L and average 11.3 mg/L. Density of TC (total coliform bacteria) was from 1000/100 mL to 114,000/100 mL and FC (fecal coliform) was 5 to 16% of TC density.

A Study on Physiochemical Analysis and Distributions of Coliforms in Major Streams or the Mankyung River (만경강 주요 지천수의 이화학적 검사 및 대장균군의 분포에 관한 연구)

  • 황인담;기노석;정인호;최문철;이재형
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.11-23
    • /
    • 1989
  • This study was performed to investigate present water quality and pollution characteristics of them in the basin area of the Mankyung river near Chonju urban stream. In order to obtain the pollution characteristics of this investigation, the physio-chemical water analysis as temperature, pH, DO, BOD, Cd, Cu, Pb and Zn, and coliform group and their correlation analysis were determined from March to August 1988. The main results were summarized as follows 1. Each chemical constituent detected in three streams has the following variation range as pH(6.7-7.3), DO(1.3-8.9 mg/l), BOD(1.6-162.5mg/l) and water temperature was dominated by atmospheric temperature. 2. In three streams, concentration range of heavy metal was Cd N.D.-2.8 $\mu$g/l, Cu 1.1-10.2 $\mu$g/l, Pb 2.1-13.2 $\mu$g/l and Zn 25.6-62.2 $\mu$g/l, and was shown the order of Zn, Pb, Cu and Cd. 3. In the investigation on the bacteriological pollution-in the three streams. 1) The average number of general bacteria contaminated in the Chonju urban stream was $1.7 \times 10^{5}$ numbers/ml, which was higher than $2.6 \times 10^{2}$ numbers/ml, in the Gosan stream and 1.6 $\times$ 10 numbers/ml in the Mankyung river. 2) The average number of total coliform, fecal coliform and fecal streptococcus contaminated in the Chonju urban stream which was the highest polluted site than those of the other sampling sites were respectively $2.1 \times 10^{5}$, $2.1 \times 10^{5}$ and $9.6 \times 10^{4}$ MPN/100ml. 4. Correlation coefficient between GB and TC in the Chonju stream, Gosan stream and Mankyung river was respectively 0.99, 0.96 and 0.99, Correlation coefficient between TC and FC in Chonju stream, Gosan stream and Mankyung river was respectively 0.99, 0.97 and 0.99 and correlation coefficient between FC and TC was respectively 0.99, 0.91 and 0.99. This results mean positively dose relationship between them. 5. The occupied percentage of FC of TC in the Chonju stream, Gosan stream and Mankyung river was respectively 88.1%, 68.4% and 77.9% and the percentage of Tc of TS was respectively 43.5%, 31.6% and 41.4%. These .results was considered indicative of pollution derived from domestic wastes which had been contaminated by the feces of inhabitants and domestic animals.

  • PDF

Sanitary assessment of the oyster rack culture waters in Wando, Korea (완도군 군외면 연안 수평망식 참굴 (Crassostrea gigas) 양식해역의 세균학적 수질 평가)

  • Kang, Ju Hyun;Cho, Sang-Man;Kim, Tae Ok;Park, Kwon Sam
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.129-136
    • /
    • 2015
  • To introduce an oyster rack culture in tidal flat of Wando-gun, Korea, we investigated sanitary conditions from 2012 April to 2013 March in oyster growing waters and adjacent area in Wando. Average seawater temperature and salinity ranged $8.6-28.0^{\circ}C$ and 26.2-33.6 psu, respectively. The coliform group and fecal coliform of seawater ranged < 1.8-13.0 MPN/100 mL each. Only one of 60 samples was exceeded in the European criteria of fecal coliform. Influence of adjunct basin's pollution load on cultural waters was negligible, which half radius of dilution was not above 300 m. According to our observation, however, landing of oyster should be banned for at least 5 days after the heavy rainfall. Our findings meet the sanitary seawater criteria for domestic use and export of shellfish and classified as 'Class A' in European Community regulations for bivalve culture.

Feasibility Study of Intermittent Slow Sand Filtration for Agricultural Reuse of Reclaimed Water (농업적 용수재이용을 위한 간헐분사 완속모래여과 하수재처리 효율 평가)

  • 윤춘경;정광욱;함종화;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.160-170
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of intermittent slow sand filtration for agricultural reuse of reclaimed water. The effluent of biofilter for 16-unit apartment was used as influent to the slow sand filtration system at 0.6 $m^3$/day loading rate using 15 seconds spray in every 10 minutes on the about 1 $m^2$ surface area and 0.5 m depth. The influent concentrations of total coliform (TC), fecal coliform (FC) and E. coli were in the range of 10.000 MPN/100 mL. and they were reduced to less than 1,000 MPN/100 mL after filtration with average of 320, 270, and 154 MPN/100 mL, respectively, showing over 95 % removal. Turbidity and SS were improved effectively and their average concentration was reduced to 0.8 NTU and 1.7 mg/L, respectively, and removal rate was about 50 %. Average BOD and COD concentrations were also reduced substantially to 2.6 and 25.8 mg/L with about 55 and 21 % removal rate, respectively. Nutrients removal was relatively low and removal rate for T-N and T-P was low however, remaining nutrients might be beneficial and less concerned in case of agricultural reuse. The concentration of biofilter effluent used in this experiment was in the range of secondary treatment effluent but slightly stronger than the one from existing wastewater treatment plants (WWTPs). Therefore, intermittent slow sand filtration might be also applicable to the effluent from WWTPs as long as its agricultural reuse is available. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, the intermittent slow sand filtration was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper is a preliminary result from pilot study and further investigations are recommended on the optimum design parameters before full scale application.

Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse (자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

Validation of Korean Water Quality Standards to Hot Springs for Agreement with Legionella-Incidence Risk (레지오넬라균 출현위해도에 대한 현행 온천수 수질기준의 적합성 분석)

  • Kim, Jin-Nam;Lee, Soyoung;Zo, Young-Gun
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.3
    • /
    • pp.259-266
    • /
    • 2015
  • Observed trends in climate change, globalization and an aging population have an effect on public health conditions in Korea, prompting a reevaluation of current environmental regulations. In this study, we evaluated the performance of the total coliform (TC) standard, which is the only microbiological standard in the current regulation regime for hot spring water, by estimating correlation with the presence/absence of Legionella, a non-fecal opportunistic pathogen with heat-tolerance. Microbiological data in 7 studies that surveyed Legionella in hot spring waters were subjected to meta-analyses with the odds ratio (OR) as the effect size. The presence/absence of Legionella was significantly correlated to TC levels [OR = 3.1(1.5–6.4, 95% CI), p = 0.002]. Due to there being no direct explanation as to the reason for the occurrence of TC, mesophilic fecal bacteria, being coupled with Legionella presence, the mechanism of the correlation between the two kinds of bacteria was further investigated. Legionella presence was more prevalent with a high heterotrophic plate count [HPC; 4.0(2.2–7.2); p < 0.001] and water temperature [4.3(1.4–13.6), p = 0.011] when the temperature range was <40℃. However, it was reverse-correlated with water temperature when the temperature was >50℃ [0.2(0.1–0.4), p < 0.001]. Therefore, bacterial standing crops in hot spring waters appear to be determined by water temperature in general, and this forces TC and Legionella levels be correlated. In accordance with this relationship, HPC rather than TC reflect the levels of non-fecal contamination better. Therefore, employing HPC as the sole microbiological standard, or adding HPC into the current standard of hot spring water assessment, is suggested as a proactive measure to prevent health issues arising from contamination.

Microbiological Quality of the Shellfish-growing Waters and Mussels in Changseon, Namhae, Korea (남해 창선해역의 해수 및 진주담치의 위생학적 안전성 평가)

  • Yoo, Hyun-Duk;Ha, Kwang-Soo;Shim, Kil-Bo;Kang, Jin Yeong;Lee, Tae-Seek;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.4
    • /
    • pp.298-306
    • /
    • 2010
  • A sanitary survey was conducted to evaluate the water quality and mussel (Mytilus edulis) conditions of two administrative shellfish growing waters: those designated as shellfish growing water for export, and adjacent waters on the east coast of Changseon Island, Namhae, Korea. In all, 1,656 seawater and 166 mussel samples were collected at 46 stations for seawater and five stations for the shellfish from January 2007 to December 2009. Both seawater and mussels were examined for total coliforms and fecal coliforms. The standard plate count and most probable number of Escherichia coli were also determined for the shellfish samples. The range of the geometric means and the estimated 90th percentiles of fecal coliform for seawater samples at each station were <1.8-4.1 MPN/100 mL and <1.8-22.3 MPN/100 mL, respectively. The sanitary conditions for both shellfish growing areas, the designated shellfish growing area and adjacent area in Changseon, met the 'Approved area' criteria of the United States National Shellfish Sanitation Program. The range of E. coli detected in mussels in these areas was <20-500 MPN/100 g; and only 3 of 166 samples exceeded 230 MPN/100 g, the European standard for the consumption of raw bivalves. Therefore, the mussel farms in the Changseon area are classified as 'Class A' according to criteria set in European Community regulations. However, the levels of E. coli in mussels in parts of the designated shellfish growing area and adjacent area exceeded the bacterial limits after rainfall exceeding 45 mm. Further studies are needed to fully define the conditions leading to a temporary closure to harvest after a rainfall event.

Investigation of Microbiological and Physiochemical Quality for Irrigation Water used in Napa Cabbage Cultivation (배추 재배에 이용되는 농업용수의 미생물 오염도 조사 및 이화학성분 분석)

  • Yun, Bohyun;Kim, Min Kyung;Ryu, Jin Hee;Kim, Won-Il;Park, Byeong-Yong;Kim, Hyun-Ju;Lee, Seung-Don;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.396-403
    • /
    • 2017
  • The purpose of this study was to investigate water quality for irrigation water used in Napa cabbage cultivation. The water samples were analyzed for physiochemical and microbiological quality for a total of 111 samples including surface water (n = 75) and groundwater (n = 36) collected from five different regions where Napa cabbage is massively grown. As a conclusion, the levels of fecal indicators for surface water were higher than those for groundwater. The numbers of coliform from surface water and groundwater were 1.96-4.96 and 0-3.98 log MPN/100 mL, respectively. Enterococci were detected in 95% (72/75) of surface water samples and 22% (8/36) of groundwater samples. Besides, 97% (73/75) of surface water samples were observed being contaminated with Escherichia coli, and 22% (8/36) of groundwater sample was positive for E. coli. In the case of surface water, E. coli and coliform correlate to T-P, and enterococci showed relevance to the suspended solid (SS) and biochemical oxygen demand (BOD). In groundwater, fecal indicator bacteria showed relevance to the SS and chemical oxygen demand (COD). These results could be provided as fundamental date for establishing microbial standard of water used in leafy vegetables cultivation.

Assessment of Bacteriological Safety of the Seawater and Ark shell (Scapharca subcrenata) in Yeoja Bay, Korea (전남 여자만 해수 및 새꼬막(Scapharca subcrenata)의 세균학적 위생 평가)

  • SHIN, SoonBum;OH, Eun Gyoung;JEONG, Sang Hyeon;LEE, Hee Jung;KIM, Yeon Kye;LEE, Tae Seek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1435-1443
    • /
    • 2016
  • This study evaluated the sanitary state of seawater and shellfish in Yeoja bay from January 2014 to June 2016. The sampling stations for sanitary survey in Yeoja Bay was composed of 50 stations for seawater and 4 stations for ark shell and the samples have been collected monthly at a stated date. The total and fecal coliforms in seawater and Escherichia coli (E. coli) in shellfish were investigated as sanitary indicator bacteria, respectively. The geometric mean and the estimated 90th percentile ranges of total and fecal coliforms for seawater were <1.8-3.9, <1.8-2.6 and <1.8-29.7, <1.8-9.3 MPN/100 mL, respectively. The range of E. coli levels for ark shell were <20~330 MPN/100 g. The sanitary state in Yeoja bay was evaluated clean area according Korea criteria and conditionally approved area according US criteria and Class B area according EU criteria.