• 제목/요약/키워드: Fe-Cr steel

검색결과 286건 처리시간 0.026초

진공다이캐스트법에 의한 Al합금과 Fe-17wt%Cr 강의 주조접합 특성연구 (A Study on the Characteristics of Cast Bonding Aluminium Alloy and Fe-17wt%Cr Steel with Vacuum Die Casting)

  • 김용현;김억수;김흥식;이광학
    • 한국주조공학회지
    • /
    • 제19권5호
    • /
    • pp.410-418
    • /
    • 1999
  • To overcome the undesirable deformation, peeling off and geometrical restrictions which were mainly caused by differences in thermal expansion coefficients during the cladding of aluminum strip and stainless strip, new processing method based on vacuum die casting is designed and implemented in fabricating Fe-17wt%Cr steel (stainless steel). To increase cast-bonding ability, the surface of Fe-17wt%Cr steel is electrochemical etched to have optimum pit size (above 0.2 mm) and pit density (above 30%). The implementation of vacuum die casting by using surface treated stainless steel (Fe-17wt%Cr Steel) produces good trial products having acceptable cast-bonding ability. The enabling conditions for cast-bonding are pouring temperature $690^{\circ}C$, filling speed 30 m/sec and casting pressure $800\;kg/cm^2$. The microscopic observation of cast-bonded Al/Fe-17wt%Cr steel does not show any evidence of intermetallic compounds. The bonding strength of trial products is $150-400\;kg/cm^2$ and this is stronger than conventionally cladded metal having $30-70\;kg/cm^2$.

  • PDF

Determining Factors for the Protectiveness of the Passive Film of FeCrN Stainless Steel Formed in Sulfuric Acid Solutions

  • Ha, Heon-Young;Lee, Tae-Ho
    • Corrosion Science and Technology
    • /
    • 제12권4호
    • /
    • pp.163-170
    • /
    • 2013
  • In NaCl solutions acidified with $H_2SO_4$, Fe20Cr1.1N alloy showed enhanced pitting corrosion resistance than Fe20Cr alloy. An XPS analysis revealed that the passive film of Fe20Cr1.1N alloy contained higher cationfraction of Cr than that of Fe20Cr alloy, and nitrogen was incorporated into the film. In addition, it was found that the passive film of Fe20Cr1.1N alloy was thinner and had higher oxygen vacancy density than that of Fe20Cr alloy. Based on these observations, it was concluded that the chemical composition was the determining factor for the protectiveness of the passive film of Fe20Cr based alloy in dilute $H_2SO_4$ solution.

Corrosion of Fe-2.25%Cr-1.6%W Steel at 600 and 700℃ in N2/(0.5, 2.5)%H2S-mixed Gas

  • Lee, Dong Bok;Bak, Sang Hwan
    • 한국표면공학회지
    • /
    • 제49권4호
    • /
    • pp.339-343
    • /
    • 2016
  • ASTM T23 steel with a composition of Fe-2.25%Cr-1.6%W corroded at 600 and $700^{\circ}C$ for 5-70 h in $N_2$/(0.5, 2.5)%$H_2S$-mixed gas at 1 atm. It corroded rapidly, forming the outer FeS scale and the inner (FeS, $FeCr_2O_4$)-mixed scale. The ensuing outward diffusion of $Fe^{2+}$ ions during corrosion led to the protrusion of FeS platelets over the outer FeS scale. The formation of FeS at the surface facilitated the oxidation of Cr to $FeCr_2O_4$ in the inner scale. Since the nonprotective FeS scale existed over the whole scale, T23 steel displayed poor corrosion resistance in the $H_2S$-containing atmosphere.

Fe-16Cr-6Ni-6Mn-1.7Mo 스테인리스 합금의 700~900℃에서의 대기중 산화 (Atmospheric Oxidation of Fe-16Cr-6Ni-6Mn-1.7Mo Stainless Steel between 700 and 900℃)

  • 이동복
    • 대한금속재료학회지
    • /
    • 제49권2호
    • /
    • pp.153-160
    • /
    • 2011
  • The AISI 216L stainless steel with a composition of Fe-16Cr-6Ni-6Mn-1.7Mo (wt.%) was oxidized at $700{\sim}900^{\circ}C$ in air for 100 h. At $700^{\circ}C$, a thin $Mn_{1.5}Cr_{1.5}O_4$ oxide layer with a thickness of $0.4{\mu}m$ formed. At $800^{\circ}C$, an outer thin $Fe_2O_3$ oxide layer and a thick inner $FeCr_2O_4$ oxide layer with a total thickness of $30{\mu}m$ formed. The non-adherent scale formed at $800^{\circ}C$ was susceptible to cracking. At $900^{\circ}C$, an outer thin $Fe_2O_3$ oxide layer and a thick inner $Mn_{1.5}Cr_{1.5}O_4$ oxide layer formed, whose total thickness was $10{\sim}15{\mu}m$. The scales formed at $900^{\circ}C$ were non-adherent and susceptible to cracking. 216 L stainless steel oxidized faster than 316 L stainless steel, owing to the increment of the Mn content and the decrement of Ni content.

Corrosion of Fe-Cr Steels at 600-800℃ in NaCl Salts

  • Lee, Dong Bok;Kim, Min Jung;Yadav, Poonam;Xiao, Xiao
    • 한국표면공학회지
    • /
    • 제51권6호
    • /
    • pp.354-359
    • /
    • 2018
  • NaCl-induced hot corrosion behavior of ASTM T22 (Fe-2.25Cr-1Mo), T91 (Fe-9Cr-1Mo), T92 (Fe-9Cr-1.8W-0.5Mo), 347HFG (Fe-18-Cr-11Ni), and 310H (Fe-25Cr-19Ni) steels was studied after spraying NaCl on the surface. During corrosion at $600-800^{\circ}C$ for 50-100 h, thick, non-adherent, fragile, somewhat porous oxide scales formed. All the alloys corroded fast with large weight gains owing to fast scaling and destruction of protective oxide scales. Corrosion rates increased progressively as the corrosion temperature and time increased. Corrosion resistance increased in the order of T22, T91, T92, 347HFG, and 310H, suggesting that the alloying elements of Cr, Ni, and W beneficially improved the corrosion resistance of steels. Basically, Fe oxidized to $Fe_2O_3$, and Cr oxidized to $Cr_2O_3$, some of which further reacted with FeO to form $FeCr_2O_4$ or with NiO to form $NiCr_2O_4$.

Al과 스텐레스강의 주조접합을 위한 STS430(Fe-17wt.%Cr)강의 표면처리 특성연구 (A Study on the Surface Characterization of Fe-17wt.%Cr Steel for Cast-bonding of Al and Stainless Steel)

  • 김억수
    • 한국주조공학회지
    • /
    • 제25권3호
    • /
    • pp.134-141
    • /
    • 2005
  • To overcome the undesirable deformation, peeling off and geometrical restrictions which were mainly caused by differences in thermal expansion coefficients during the cladding of aluminum strip and stainless strip, new processing method based on vacuum die casting is designed and implemented in fabricating Al/Fe-17wt%Cr steel(stainless steel). To increase cast-bonding ability, the surface of Fe-17wt%Cr steel is electrochemically etched to have optimum pit size and density. The optimum conditions to generate best pit are as follows: Solution: 1 M $Fecl_{3}$+1 M Nacl, Addition: $CuCl_{2}+HCl$, Current density: 80 $mA/cm^{2}$, Total current: 400 $coulomb/cm^{2}$, AC frequency :60 Hz.

Corrosion of Fe-9%Cr-1%Mo Steel at 600 and 700℃ in N2/(0.5, 2.5)%H2S-mixed Gas

  • Lee, Dong Bok;Abro, Muhammad Ali;Yadav, Poonam;Bak, Sang Hwan;Shi, Yuke;Kim, Min Jung
    • 한국표면공학회지
    • /
    • 제49권2호
    • /
    • pp.147-151
    • /
    • 2016
  • The T91 steel (Fe-9%Cr-1%Mo) was corroded at 600 and $700^{\circ}C$ for 5 - 70 h in the $N_2$/(0.5, 2.5)%$H_2$Smixed gas at one atm. It was corroded fast, forming the outer FeS layer and the inner (FeS, $FeCr_2O_4$)-mixed layer. The formation of the outer FeS layer facilitated the oxidation of Cr to $FeCr_2O_4$ in the inner layer. Since the nonprotective FeS scale was present over the whole scale, T91 steel displayed poor corrosion resistance.

Characteristics of Ni-based Alloy Bond in Diamond Tool Using Vacuum Brazing Method

  • An, Sang-Jae;Song, Min-Seok;Jee, Won-Ho
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1130-1131
    • /
    • 2006
  • We found that the """interface reaction between Ni-based alloy bond, diamond, and steel core is very critical in bond strength of diamond tool. None element from metal bond diffuses into the steel core but the Fe element of steel core was easily diffused into the bond. This diffusion depth of Fe has a great effect on the bonding strength. The Cr in steel core accelerated the Fe diffusion and improved the bond strength, on the other hand, carbon decreased the strength. Ni-based alloy bond including Cr was chemically bonded with diamond by forming Cr carbide. However, the Cr and Fe in STS304 were largely interdiffused, the strength was very low. The Cr passivity layer formed at surface of STS304 made worse strength at commissure in brazing process.

  • PDF

고체산화물 연료전지용 금속접속자로의 적용을 위한 Fe-16Cr 페라이트 합금의 내산화막 코팅 (Protective Coatings for Application of Fe-l6Cr Ferritic Alloy as an Interconnector in SOFCs)

  • 이용진;김상우;김긍호;이종호;안진호
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.139-145
    • /
    • 2003
  • Fe-Cr 합금의 고체산화물 연료전지용 금속접속자로의 적용 가능성을 알아보기 위하여 페라이틱 스틸에 내산화 물질인 Y-Cr계 산화물을 졸 코팅하여 산화 특성을 연구하였다. YCr $O_3$졸 코팅된 페라이틱 스틸은 80$0^{\circ}C$에서 40시간 열처리 후에도 Fe계 산화물은 생성되지 않고, 주상으로 YCr $O_3$그리고 소량의 C $r_2$ $O_3$와 M $n_{1.5}$C $r_{1.5}$ $O_4$산화물 등이 생성되었다. Mn-Cr계 산화물은 금속 성분인 Mn이 내부로부터 확산에 의해 산화가 진행됨에 따라 입자가 성장하였다. 모든 YCr $O_3$졸 코팅된 시편에서의 전기 저항을 나타내는 Log(ASR/T) 값은 -4.57~-4.70Ω$ extrm{cm}^2$K ̄$^1$로 코팅되지 않은 금속의 Log(ASR/T), -3.99Ω$\textrm{cm}^2$K ̄$^1$보다 작아지므로 금속접속자로의 적용 가능성을 확인할 수 있었다.있었다.

Fabrication and Magnetic Properties of A New Fe-based Amorphous Compound Powder Cores

  • Xiangyue, Wang;Feng, Guo;Caowei, Lu;Zhichao, Lu;Deren, Li;Shaoxiong, Zhou
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.318-321
    • /
    • 2011
  • A new Fe-based amorphous compound powder was prepared from Fe-Si-B amorphous powder by crushing amorphous ribbons as the first magnetic component and Fe-Cr-Mo metallic glassy powder by water atomization as the second magnetic component. Subsequently by adding organic and inorganic binders to the compound powder and cold pressing, the new Fe-based amorphous compound powder cores were fabricated. This new Fe-based amorphous compound powder cores combine the superior DC-Bias properties and the excellent core loss. The core loss of 500 kW/$m^3$ at $B_m$ = 0.1T and f = 100 kHz was obtained When the mass ratio of FeSiB/FeCrMo equals 3:2, and meanwhile the DC-bias properties of the new Fe-based amorphous compound powder cores just decreased by 10% compared with that of the FeSiB powder cores. In addition, with the increasing of the content of the FeCrMo metallic glassy powder, the core loss tends to decrease.