• Title/Summary/Keyword: Fault-Location

Search Result 474, Processing Time 0.037 seconds

Topological Locating of Power Quality Event Source

  • Won Dong-Jun;Moon Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.170-176
    • /
    • 2006
  • This paper proposes a topological locating algorithm to determine the location of the power quality event source. This algorithm makes use of the information on the topology of the monitored network and on the direction of PQ events. As a result, the bus incidence matrix is modified using monitor location and the direction matrix is constructed. With this information, the algorithm determines the suspected locations of the PQ events. To reduce suspicious areas, it utilizes event cause and related equipment. In case of line fault event, it calculates the distance from the monitor to the location of event source. The overall algorithm is applied to the IEEE test feeder and accurately identifies the event source location.

A Study on the robust fault diagnosis and fault tolerant control method for the closed-loop control systems (폐회로 제어시스템의 강인한 고장진단 및 고장허용제어 기법 연구)

  • Lee, Jong-Hyo;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.138-145
    • /
    • 2000
  • This paper presents a robust fault diagnosis and fault tolerant control method for the control systems in closed-loop affected by unknown inputs or disturbances. The fault diagnostic scheme is based on the disturbance-decoupled state estimation using a 2-stage state observer for state, actuator bias and sensor bias. The estimated bias show the occurrence time, location and type of the faults directly. The estimated state is used for state feedback to achieve fault tolerant control against the faults. Simulation results show that the method has definite fault tolerant ability against actuator and sensor faults, moreover, the faults can be detected on-line, isolated and estimated simultaneously.

  • PDF

Fault segmentation along the Ulsan Fault System based on criteria of segment type (단층분절을 정의하는 기준에 따른 울산단층의 분절화)

  • Choi, Weon-Hack;Chang, Chun-Joong;Inoue D.
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.78-85
    • /
    • 2006
  • The Ulsan Fault System continues from north of Gyeongju to Ulsan city, trending NNW-SSE and is about 50 km. Many Quaternary faults have been reported and investigated with outcrop observation. Lineaments have been extracted with aerial photograph interpretation and classified by their ranks. Trench excavations on the lineaments along Ulsan Fault System have been carried out to clarify the neotectonic movements and fault parameters such as the latest movement age, fault displacement, slip rate and recurrence interval. We have compiled data from previous studies on criteria of segment type such as lineament rank, seismicity, slip rate, and the latest fault movement. Based on these data, we tried to devide the Ulsan Fault System into several segments. The results of segmentation with each types of segment along the Ulsan Fault System did not show singular division point but overlapped or different length and location.

  • PDF

Analysis on Application Location of SFCL according to Circuit Breaker Burden Index with Weight Factor Estimation (차단기 부담 평가지표의 가중치 산정에 따른 초전도 한류기 적용위치 분석)

  • Park, Han-Min;Lee, Hyeong-Jin;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.47-53
    • /
    • 2015
  • As the industrial development in Korea, the power demand is rapidly increased. The power system has been extended and complicated to meet the power demand. However, the fault current increases because the structure of power system reduces the equivalent impedance. One of the solutions to reduce the fault current is Superconducting Fault Current Limiter(SFCL) and the researches of SFCL application have much conducted. In this paper, we used the Circuit Breker Burden Index(CBBI) to select application location of SFCL because the CBBI may consider a fault current of each line. In addition, this paper divided the weight factor used to calculate the CBBI on a case by case basis and analyzed this characteristics through experiment.

Estimation of Fault Location on a Transmission Line via Time-Frequency Domain Reflectometry (시간-주파수 반사파 계측 방법을 이용한 전송선로의 결함 위치 추정)

  • Choe TokSon;Kwak Ki-Seok;Yoon Tae Sung;Park Jin Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.521-530
    • /
    • 2005
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry(TFDR), isproposed to detect and estimate a fault in a transmission line. Traditional reflectometry methodologies have been achieved either in the time domain or in the frequency domain only. However, the TFDR can jump over the performance limits of the traditional reflectometry methodologies because the acquired signal is analyzed in time and frequency domain simultaneously. In the TFDR, the new reference signal and the novel TFDR algorithm are proposed for analyzing the acquired signal in the time-frequency domain. Because the reference signal of Gaussian envelop chirp signal is localized in the time and frequency domain simultaneously, it is suitable to the analysis in the time-frequency domain. In the proposed TFDR algorithm, the time-frequency distribution function and the normalized time-frequency cross correlation function are used to detect and estimate a fault in a transmission line. That algorithm is verified for real-world coaxial cables which are typical transmission line with different types of faults by the TFDR system composed of real instruments. The performance of the TFDR methodology is compared with that o( the commercial time domain reflectomeoy(TDR) experiments, so that concludes the TFDR methodology can detect and estimate the fault with smaller error than TDR methodology.

An Optimal Location of Superconducting Fault Current Limiter in Distribution Network with Distributed Generation Using an Index of Distribution Reliability Sensitivity (신뢰도 민감도 지수를 이용한 복합배전계통 내 초전도한류기의 최적 위치에 관한 연구)

  • Kim, Sung-Yul;Kim, Wook-Won;Bae, In-Su;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.52-59
    • /
    • 2010
  • As electric power demand of customers is constantly increasing, more bulk power systems are needed to install in a network. By development of renewable energies and high-efficient facilities and deregulated electricity market, moreover, the amount of distributed resource is considerably increasing in distribution network consequently. Also, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. These changes make fault current increase. Therefore, the fault current will exceed a circuit breaker capacity. In order to solve this problem, replacing breaker, changing operation mode of system and rectifying transformer parameters can be taken into account. The SFCL(Superconducting Fault Current Limiter) is one of the most promising power apparatus. This paper proposes a methodology for on optimal location of SFCL. This place is defined as considering the decrement of fault current by component type and the increment of reliability by customer type according to an location of SFCL in a distribution network connected with DG(Distributed Generation). With case studies on method of determining optimal location for SFCL applied to a radial network and a mesh network respectively, we proved that the proposed method is feasible.

Numerical Algorithm for Distance Protection and Arcing Fault Recognitior (고장거리계산과 아크고장 판별 알고리즘)

  • Radojevic, Zoran;Park, K.W.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.163-165
    • /
    • 2002
  • In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition based on one terminal data and derived in lime domain is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage at the fault place is modeled as a serial connection of fault resistance and arc voltage. The fault distance and arc voltage amplitude are estimated using Least Error Squares Technique. The algorithm can be applied for distance protection, intelligent autoreclosure and for fault location. The results of algorithm tested through computer simulation are given.

  • PDF

Fault Diagnosis of Multistage Baseline Network (다단 베이스라인 네트워크의 오류진단)

  • Oh, Jae-Chul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.6
    • /
    • pp.860-867
    • /
    • 1986
  • It was shown previously that four tests are required in order to detect single fault and to locate single link stuck fault for a class of multistage interconnection networks. In this paper, we show that only three tests are necessary and sufficient both to detect single fault and to locate single link stuck fault. A fault diagnosis method with four valid state for a class of multistage kinterconnection networks is presented. Using this method, all single link stuck fault or all single switching element faults, can be detected by at most 4 log2N+e tests. In the example, the location and type of single fault are pinpointed, and unlocatable probabilities of questionable of questionable regions are given.

  • PDF

Influence of the Interconnected Wind farm on Protection for Distribution Networks (풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향)

  • 장성일;김광호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation

  • Radojevic, Zoran;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.79-81
    • /
    • 2003
  • This paper presents development and testing of a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and the fault distance calculation. The arc voltage amplitude and the fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation are given.

  • PDF