• 제목/요약/키워드: Fault simulation

검색결과 1,315건 처리시간 0.024초

혼합송전계통에서 웨이브렛 변환을 이용한 고장점 탐색 알고리즘에 관한 연구 (A Study on a Fault Location Algorithm Using Wavelet Transform in Combined Transmission Systems)

  • 정채균;이종범;윤양웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권5호
    • /
    • pp.247-254
    • /
    • 2002
  • This paper describes a fault location algorithm in real combined transmission systems with underground power cable. The algorithm to calculate the fault location was developed using DWT wavelet transform and travelling wave occurred at fault point. And the proposed algorithm is also used the transient signal of one end in stead of the signal information of two ends. On the other hand, in this papers, the method to discriminate fault point between overhead line and cable section is also Proposed. Variety simulations were carried out to verify the accuracy and effectiveness of the proposed algorithm using EMTP/ATFDraw and Matlab. Simulation results show that the proposed method has the excellent ability for discrimination of fault section and fault location in combined transmission systems with power cables.

Detection of Stator Winding Inter-Turn Short Circuit Faults in Permanent Magnet Synchronous Motors and Automatic Classification of Fault Severity via a Pattern Recognition System

  • CIRA, Ferhat;ARKAN, Muslum;GUMUS, Bilal
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.416-424
    • /
    • 2016
  • In this study, automatic detection of stator winding inter-turn short circuit fault (SWISCFs) in surface-mounted permanent magnet synchronous motors (SPMSMs) and automatic classification of fault severity via a pattern recognition system (PRS) are presented. In the case of a stator short circuit fault, performance losses become an important issue for SPMSMs. To detect stator winding short circuit faults automatically and to estimate the severity of the fault, an artificial neural network (ANN)-based PRS was used. It was found that the amplitude of the third harmonic of the current was the most distinctive characteristic for detecting the short circuit fault ratio of the SPMSM. To validate the proposed method, both simulation results and experimental results are presented.

연식주퇴 시스템의 오류모드 제어기법에 관한 연구 (A Study on Fault Mode Control of a Soft Recoil System)

  • 신철봉;배재성;황재혁;강국정
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.255-259
    • /
    • 2008
  • A soft-recoil system, which is a new technology, can dramatically reduce a recoil force. Due to the inaccurate explosion, various fault modes may happen. These fault modes can cause the serious damage of the recoil system and must be suppressed to avoid them. In the present study, the fault mode control method of the soft-recoil system is investigated. A hydraulic damper is working under normal mode and a MR damper is additionally working when the fault modes happen. In the design of the fault mode controller, the detection method of the fault mode is important as well as its suppression. The results of the simulation show that the soft-recoil system performs when the fault modes happen.

  • PDF

진행파를 이용한 송전선로의 고장점 표정 알고리즘 (A Fault Location Algorithm for a Transmission Line Using Travelling Waves)

  • 강상희;김진한
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.542-549
    • /
    • 2004
  • The conventional fault location algorithms based on the travelling waves have an inherent problem. In cases of the close-up faults occurring near the relaying point and of the faults having zero degree inception angle of voltage signals, the conventional algorithms can not estimate an accurate fault distance. It is because the shapes of travelling waves are near sinusoidal in those cases. A new method solving this problem is presented in this paper. An FIR(Finite Impulse response) filter which makes high frequency components prominent and makes the power frequency component and dc-offset attenuated is used. With this method, the cross-correlation peak is to be very clear when a close-up fault or a fault having near zero-degree inception angle occurs. The cross-correlation peaks can be clearly distinguished and accurate fault location is practically possible consequently. A series of simulation studies using EMTP(Electromagnetic Transients Program) show that the proposed algorithm can calculate an accurate fault distance having maximum 2% or less error.

ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구 (A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI))

  • 박재흥;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

고장거리계산과 아크고장 판별 알고리즘 (Numerical Algorithm for Distance Protection and Arcing Fault Recognitior)

  • ;박경원;박장수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.163-165
    • /
    • 2002
  • In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition based on one terminal data and derived in lime domain is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage at the fault place is modeled as a serial connection of fault resistance and arc voltage. The fault distance and arc voltage amplitude are estimated using Least Error Squares Technique. The algorithm can be applied for distance protection, intelligent autoreclosure and for fault location. The results of algorithm tested through computer simulation are given.

  • PDF

규칙 기반의 네트워크 장애 자기 복구 시스템 (Rule-based network fault self-recovery system)

  • 이재욱;안성진;정진욱
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제10권1호
    • /
    • pp.83-93
    • /
    • 2006
  • 본 논문에서는 유비쿼터스 컴퓨팅 환경에서 규칙 기반의 네트워크 장애 복구 시스템을 제안한다. 이 시스템은 유비쿼터스 컴퓨팅 환경에서 네트워크에 장애가 발생하였을 때, 정해진 규칙을 기반으로 장애를 스스로 복구할 수 있는 장애 관리 시스템이다. 시스템에 적용되는 규칙들을 네트워크 장애의 원인으로 분류하여 제시하였다. 그리고 본 논문에서는 네트워크 장애 복구 시스템이 각 상황에 맞게 규칙이 적용됨을 시뮬레이션을 통해 증명하였다.

  • PDF

Fault Diagnosis and Accommodation of Linear Stochastic Systems with Unknown Disturbances

  • Lee, Jong-Hyo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.270-276
    • /
    • 2002
  • An integrated robust fault diagnosis and fault accommodation strategy for a class of linear stochastic systems subjected to unknown disturbances is presented under the assumption that only a single fault may occur at a given time. The strategy is based on the fault isolation and estimation using a bank of robust two-stage Kalman filters and introduction of the additive compensation input for cancelling out the fault's effect on the system. Each filter is set up such that the residual is decoupled from unknown disturbances and fault with the influence vector designed in the filter. Simulation results for the simplified longitudinal flight control system with parameter uncertainties, process and sensor noises demonstrate the effectiveness of the present approach.

SWT와 진행파를 이용한 지중송전계통 고장점 추정 기법 개발 (Development of Fault Location Method Using SWT and Travelling Wave on Underground Power Cable Systems)

  • 정채균;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.184-190
    • /
    • 2008
  • The fault location algorithm based on stationary wavelet transform was developed to locate the fault point more accurately. The stationary wavelet transform(SWT) was introduced instead of conventional discrete wavelet transform(DWT) because SWT has redundancy properties which is more useful in noise signal processing. In previous paper, noise cancellation technique based on the correlation of wavelet coefficients at multi-scales was introduced, and the efficiency was also proved in full. In this paper, fault section discrimination and fault location algorithm using noise cancellation technique were tested by ATP simulation on real power cable systems. From these results, the fault can be located even in very difficult and complicated situations such as different inception angle and fault resistance.