• 제목/요약/키워드: Fault distance

검색결과 372건 처리시간 0.021초

A Fast Algorithm of the Apparent Factor Calculation for Distance Relay Setting without Fault Analysis

  • Jo, Yong-Hwan;Xiang, Ling;Choi, Myeon-Song;Park, Ji-Seung;Lim, Seong-Il;Kim, Sang-Tae;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.64-69
    • /
    • 2013
  • For power system protection, the distance relay settings are important. Apparent factor is a necessary parameter in distance relay settings. Apparent factors have to be calculated when setting the distance relays and doing the resetting in case of configuration change in power system. The problem is that the current method to calculate apparent factor requires tools and plenty of time to do fault analysis and this method is complex especially in case of configuration change. Therefore this paper proposes a fast algorithm to calculate apparent factor without the fault analysis. Test results prove that this algorithm is simple and accurate by simulation.

송전선로용 디지털 고장점 표정장치에 관한 연구 (A Study on Digital Fault Locator for Transmission Line)

  • 이경민;박철원
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

자동 재폐로기의 동작책무를 위한 아크전압 판정 및 사고거리 표정 알고리즘 (A Numerical Algorithm for Fault Location Estimation and Arc Faults Detection for Auto-Reclosure)

  • 김병만;채명석;정태영;강용철
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1294-1303
    • /
    • 2009
  • This paper presents a new numerical algorithm for fault discrimination and fault location estimation when occur to arcing ground and arcing line to line on transmission lines. The object of this paper is developed from new numerical algorithm to calculate the fault distance and simultaneously to make a distinction between transient and permanent faults. so the first of object for propose algorithm would be distinguish the permanent from the transient faults. This arcing fault discrimination algorithm is used if calculated value of arc voltage amplitude is greater than product of arc voltage gradient and the length of the arc path, which is equal or greater than the flashover length of a suspension insulator string[1-3]. Also, each algorithm is separated from short distance and long distance. This is difference to with/without capacitance between short to long distance. To test the validity of the proposed algorithms, the results of algorithm testing through various computer simulations are given. The test was simulated in EMTP/ATP simulator under a number of scenarios and calculate of algorithm was used to MATLAB.

사고 패턴 분류에 기초한 배전계통의 적응 재폐로방식 (An Adaptive Reclosing Scheme Based on the Classification of Fault Patterns in Power distribution System)

  • 오정환;김재철;윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.112-119
    • /
    • 2001
  • This paper proposes an adaptive reclosing scheme which is based on the classification of fault patterns. In case that the first reclosing is unsuccessful in distribution system employing with two-shot reclosing scheme, the proposed method can determine whether the second reclosing will be attempted of not. If the first reclosing is unsuccessful two fault currents can be measured before the second reclosing is attempted, where these two fault currents are utilized for an adaptive reclosing scheme. Total harmonic distortion and RMS are used for extracting the characteristics of two fault currents. And the pattern of two fault currents is respectively classified using a mountain clustering method a minimum-distance classifier. Mountain clustering method searches the cluster centers using the acquired past data. And minimum-distance classifier is used for classifying the measured two currents into one of the searched centers respectively. If two currents have the different pattern it is interpreted as temporary fault. But in case of the same pattern, the occurred fault is interpreted as permanent. The proposed method was tested for the fault data which had been measured in KEPCO's distribution system, and the test results can demonstrate the effectiveness of the adaptive reclosing scheme.

  • PDF

765㎸ 비연가 송전선로에서 고장점 표정 알고리즘 (A New fault Location Algorithm for 765㎸ Untransposed Parallel Transmission Lines)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • This paper describes a new fault location algorithm based on the voltage equation at the relaying point using 6-phase current for untransposed 765㎸ parallel transmission lines. The proposed method uses the voltage and current collected at only the local end. By means of 3-phase circuit analysis theory to compensate the mutual coupling effects between parallel lines, the fault location is derived. The fault distance is determined by solving the 2nd distance equation based on KVL(Kirchhoff's Voltage Law). Extensive simulation results using EMTP(Electromagnatic Transients Program) have verified that the error of the fault location achieved is up to 4.56(%) in untransposed parallel transmission lines.

모의 송전계통에 초전도한류기의 적용에 따른 거리계전기의 동작특성 연구 (Analysis on Operational Characteristics of Distance Relay due to Application of Superconducting Fault Current Limiter in a Simulated Power Transmission System)

  • 노신의;김진석;김이관;김재철;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.40-46
    • /
    • 2014
  • The development of the superconducting fault current limiter (SFCL) to apply into a power transmission system where makes larger fault current compared to the power distribution system has been performed. Among various SFCLs, the trigger-type SFCL is suitable for application into the power transmission system due to the effective reduction on power burden of the high temperature superconducting element (HTSC) for the larger fault current. To protect the power transmission line in the power grid, the distance relay, which decides to interrupt fault section where can be calculated by the measured voltage and current from sound grid, is one of important protective devices in the power transmission system. However, the operation of the distance relay from the impedance of the fault point on the transmission line is affected by the impedance of the trigger-type SFCL. Therefore, the analysis on the operational characteristics of distance relay considering the application of the SFCL is required. In this paper, the effect on the operation zones of the distance relay by the impedance of the SFCL in a power transmission system was analyzed through the PSCAD/EMTDC simulation.

송전선로에 있어서 Mutual Coupling을 고려한 디지털 거리계전기의 신뢰도 향상 (An Improvement of Digital Distance Relay Reliability considering Mutual Coupling in Transmission Lines)

  • 최석민;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1025-1027
    • /
    • 1997
  • In this paper, the digital distance relay of transmission lines under fault conditions is discussed. Distance relay is used to protect transmission lines. The principle of distance relay is well-known ; the impedance measured by a relay is Proportional to the distance from the relay to the fault. Hence, by measuring the impedance, it can be determined whether the line is faulted or not. Unfortunately, the measurement of the fault distance is distorted by Mutual Coupling. To implement more reliable and practical digital distance relay, the mutual coupling effect has to be considered.

  • PDF

An Improved Method for Fault Location based on Traveling Wave and Wavelet Transform in Overhead Transmission Lines

  • Kim, Sung-Duck
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.51-60
    • /
    • 2012
  • An improved method for detecting fault distance in overhead transmission lines is described in this paper. Based on single-ended measurement, propagation theory of traveling waves together with the wavelet transform technique is used. In estimating fault location, a simple, but fundamental method using the time difference between the two consecutive peaks of transient signals is considered; however, a new method to enhance measurement sensitivity and its accuracy is sought. The algorithm is developed based on the lattice diagram for traveling waves. Representing both the ground mode and alpha mode of traveling waves, in a lattice diagram, several relationships to enhance recognition rate or estimation accuracy for fault location can be found. For various cases with fault types, fault locations, and fault inception angles, fault resistances are examined using the proposed algorithm on a typical transmission line configuration. As a result, it is shown that the proposed system can be used effectively to detect fault distance.

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.

IP-USN 기반의 홈 네트워크 환경에서 결함 감지 에이전트를 위한 신뢰성 (Reliability for A Fault-Detection Agent running on Home Network Environment based IP-USN)

  • 고응남
    • 한국항행학회논문지
    • /
    • 제13권1호
    • /
    • pp.74-78
    • /
    • 2009
  • 본 논문은 IP-USN 기반의 FDA(Fault Detection Agent)의 설계와 구축을 설명한다. FDA는 IP-USN 기반의 홈 네트워크 환경에서 멀티미디어 원격 교육을 위한 소프트웨어 오류를 감지하기에 적합한 에이전트이다. 이 시스템은 ED, ES로 구성되어 있다. ED는 IP-USN 기반 환경에서 멀티미디어 원격 교육을 위하여 훅킹 기법으로 오류를 감지하는 에이전트이다. ES는 IP-USN 기반 환경에서 멀티미디어 원격 교육을 위하여 오류를 공유하는 에이전트이다.

  • PDF