• 제목/요약/키워드: Fault displacement

검색결과 172건 처리시간 0.028초

Vertical equipment isolation using piezoelectric inertial-type isolation system

  • Lu, Lyan-Ywan;Lin, Ging-Long;Chen, Yi-Siang;Hsiao, Kun-An
    • Smart Structures and Systems
    • /
    • 제26권2호
    • /
    • pp.195-211
    • /
    • 2020
  • Among anti-seismic technologies, base isolation is a very effective means of mitigating damage to structural and nonstructural components, such as equipment. However, most seismic isolation systems are designed for mitigating only horizontal seismic responses because the realization of a vertical isolation system (VIS) is difficult. The difficulty is primarily due to conflicting isolation stiffness demands in the static and dynamic states for a VIS, which requires sufficient rigidity to support the self-weight of the isolated object in the static state, but sufficient flexibility to lengthen the isolation period and uncouple the ground motion in the dynamic state. To overcome this problem, a semi-active VIS, called the piezoelectric inertia-type vertical isolation system (PIVIS), is proposed in this study. PIVIS is composed of a piezoelectric friction damper (PFD) and a leverage mechanism with a counterweight. The counterweight provides an uplifting force in the static state and an extra inertial force in the dynamic state; therefore, the effective vertical stiffness of PIVIS is higher in the static state and lower in the dynamic state. The PFD provides a controllable friction force for PIVIS to further prevent its excessive displacement. For experimental verification, a shaking table test was conducted on a prototype PIVIS controlled by a simple controller. The experimental results well agree with the theoretical results. To further investigate the isolation performance of PIVIS, the seismic responses of PIVIS were simulated numerically by considering 14 vertical ground motions with different characteristics. The responses of PIVIS were compared with those of a traditional VIS and a passive system (PIVIS without control). The numerical results demonstrate that compared with the traditional and passive systems, PIVIS can effectively suppress isolation displacement in all kinds of earthquake with various peak ground accelerations and frequency content while maintaining its isolation efficiency. The proposed system is particularly effective for near-fault earthquakes with long-period components, for which it prevents resonant-like motion.

경사계를 이용한 대구 서부지역 반야월층 굴착 지반의 변위 분석 (Displacement Analysis of an Excavation Wall using Inclinometer Instrumentation Data, Banyawol Formation, Western Daegu)

  • 임명혁
    • 지질공학
    • /
    • 제23권1호
    • /
    • pp.47-55
    • /
    • 2013
  • 대구 지하철 굴착공사 중 노출된 굴착벽의 수평변위분석을 위해 서로 인접한 3개소의 경사계 계측자료를 이용하여 굴착지반의 변위특성 및 원인을 지질공학적 관점에서 고찰하였다. 연구지역은 경상누층군 하양층군 반야월층 지반에 해당하며 안산암질화산암, 석회질셰일, 사암, 호온펠스, 규장암맥 등으로 구성된 하부의 암반층과 이를 부정합으로 피복하고 있는 상부의 토사층으로 구성된다. 경사계 계측공 중 D4 지반의 암반층은 RMR V 등급이며, 층리면과 단층면을 따라 심도 12 m 지점에서 N34W 방향으로 최대수평변위량이 101.39 mm로 분석 되었고, D5 지반의 암반층은 RMR IV 등급이며, 셰일의 층리면, 셰일과 규장암의 접촉면을 따라 심도 9 m와 14 m에서 거의 남쪽 방향으로 최대수평변위량이 53.01 mm ~ 55.17 mm로 측정 되었다. Y6 지반의 암반층은 RMR III 등급이며, 상부 토사층과 하부 암반층의 경계면인 부정합면을 따라 심도 7 m 지점에서 S52W 방향으로 12.65 mm의 최대수평변위량을 나타낸다. 굴착벽에서 측정한 암반 내 불연속면들을 평사투영하여 예상되는 변위방향과 각 경사계 계측분석 결과 얻어진 수평변위방향이 거의 일치하는 결과를 보였으며, 굴착벽의 지중수평변위는 암반 내 불연속면의 발달정도와 종류, 배향 및 암석의 종류에 좌우되며, 굴착벽에 수직방향과 수평평행방향의 벡터 합성 방향으로 많이 발생한다. 또한 토사층 내 지중수평변위의 양상이 심도에 따라 비교적 곡선이며 연속적 궤적을 보이는데 반해 암반층 내 지중수평변위의 양상은 직선적이고 불규칙적 궤적을 나타낸다.

유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1) (Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1))

  • 박정욱;박의섭;김태현;이창수;이재원
    • 터널과지하공간
    • /
    • 제28권5호
    • /
    • pp.400-425
    • /
    • 2018
  • 본 논문에서는 국제공동연구인 DECOVALEX-2019 프로젝트 Task B의 연구결과와 현황을 소개하였다. Task B의 주제는 'Fault slip modelling'으로 유체의 주입으로 인해 발생하는 단층의 재활성(미끄러짐, 전단파괴)과 수리역학적 거동을 예측할 수 있는 해석기법을 개발하는 데에 그 목적이 있다. 1단계 연구는 참가팀들이 연구주제에 대해 숙지하고, 벤치마크 모델을 대상으로 단층의 투수특성과 역학적 거동의 상호작용을 모사할 수 있는 해석코드를 개발할 수 있도록 하는 준비 단계의 연구이다. 본 연구에서는 TOUGH-FLAC 연동해석 기법을 사용하여 물 주입으로 인한 단층의 수리역학적 연계거동을 모사하였다. TOUGH2 해석에서는 단층을 Darcy의 법칙과 삼승법칙을 따르는 연속체 요소로 모델링하였으며, FLAC3D 해석에서는 미끄러짐과 개폐가 허용되는 불연속 인터페이스 요소를 통해 모사하였다. 두 가지 수리간극모델에 대하여 수리역학적 커플링 관계식을 수치화하였으며, 연속체 요소(수리모델)와 인터페이스 요소(역학모델)의 거동을 연계할 수 있는 해석기법을 제시하였다. 또한, 단층의 역학적 변형(간극의 변화)으로 인한 수리물성 변화와 기하학적 변화(해석 메쉬의 변형)를 수리해석에 반영할 수 있는 해석기법을 개발하였다. 다양한 압력의 물을 단계적으로 주입하고 이로 인해 유도되는 단층의 탄성거동 및 전단파괴(미끄러짐)에 대해 살펴보았으며, 수리간극의 변화 양상과 원인, 압력 분포와 주입율의 관계 등을 면밀히 검토하였다. 해석 결과, 본 연구에서 개발한 해석기법이 물 주입으로 인한 단층의 미끄러짐 거동을 합리적인 수준에서 재현할 수 있는 것으로 판단할 수 있었다. 본 연구의 해석모델은 Task B에 참여하는 국외 연구팀들과의 의견 교류와 워크숍을 통해 지속적으로 개선하는 한편, 향후 연구의 현장시험에 적용하여 타당성을 검증할 예정이다.

유체 주입에 의한 단층 재활성 해석기법 개발: 국제공동연구 DECOVALEX-2019 Task B(Benchmark Model Test) (Coupled Hydro-Mechanical Modelling of Fault Reactivation Induced by Water Injection: DECOVALEX-2019 TASK B (Benchmark Model Test))

  • 박정욱;김태현;박의섭;이창수
    • 터널과지하공간
    • /
    • 제28권6호
    • /
    • pp.670-691
    • /
    • 2018
  • 본 논문에서는 국제공동연구 DECOVALEX-2019 프로젝트의 일환으로 수행된 Task B Benchmark Model Test(BMT)의 연구 결과를 소개하였다. Task B는 'Fault slip modelling'을 연구주제로 하며, 유체의 주입으로 인해 발생하는 단층의 재활성과 수리역학적 연계거동을 예측할 수 있는 해석기법을 개발하는 데에 목적이 있다. BMT 시나리오 해석은 각 참가팀들의 수치모델이 단층의 수리역학적 연동거동을 적절히 모사할 수 있는지 교차검증함으로써 각 해석코드의 완성도를 높이기 위하여 수행되었으며, 주입압 적용 조건, 단층 물성, 수리역학적 연동해석 조건 등에 따라 7개의 해석 모델로 이루어져 있다. 본 연구에서는 TOUGH-FLAC 연동해석 기법을 이용하여, 역학적 변형으로 야기되는 단층의 수리적 물성 변화와 간극의 기하학적 변화를 동시에 반영할 수 있는 수리역학적 커플링 모듈을 개발하였다. BMT 시나리오 해석을 위하여 Task B 1단계(Step 1) 연구에서 개발된 수치모델을 일부 수정하였고, 단층의 변형에 따른 압축률과 투수계수, 단층의 해석 메쉬의 변화가 해석에 반영될 수 있도록 하였다. 단층의 투수량계수와 저류계수가 단층 내 압력 분포, 주입수량, 변위, 응력 등 수리역학적 거동에 미치는 영향을 검토하였으며, 수정된 수치모델을 기수행된 1단계 연구에 적용하여 해석결과를 업데이트하였다. 해석 결과, 본 연구에서 개발한 해석기법이 물 주입으로 인한 단층의 거동을 합리적인 수준에서 재현할 수 있는 것으로 판단할 수 있었다. 본 연구의 해석모델은 Task B에 참여하는 국외 연구팀들과의 의견 교류와 워크숍을 통해 지속적으로 개선하는 한편, 향후 연구의 현장시험에 적용하여 타당성을 검증할 예정이다.

Reliability-based design of semi-rigidly connected base-isolated buildings subjected to stochastic near-fault excitations

  • Hadidi, Ali;Azar, Bahman Farahmand;Rafiee, Amin
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.701-721
    • /
    • 2016
  • Base isolation is a well-established passive strategy for seismic response control of buildings. In this paper, an efficient framework is proposed for reliability-based design optimization (RBDO) of isolated buildings subjected to uncertain earthquakes. The framework uses reduced function evaluations method, as an efficient tool for structural reliability analysis, and an efficient optimization algorithm for optimal structural design. The probability of failure is calculated considering excessive base displacement, superstructure inter-storey drifts, member stress ratios and absolute accelerations of floors of the isolated building as failure events. The behavior of rubber bearing isolators is modeled using nonlinear hysteretic model and the variability of future earthquakes is modeled by applying a probabilistic approach. The effects of pulse component of stochastic near-fault ground motions, fixity-factor of semi-rigid beam-to-column connections, values of isolator parameters, earthquake magnitude and epicentral distance on the performance and safety of semi-rigidly connected base-isolated steel framed buildings are studied. Suitable RBDO examples are solved to illustrate the results of investigations.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

강우로 인한 터널내부 과다변위 사례 연구 (A case study on excessive displacements occurred in the tunnels caused by rainfall)

  • 김낙영;김홍종;오영석;김창용;양태선
    • 한국터널지하공간학회 논문집
    • /
    • 제14권6호
    • /
    • pp.561-573
    • /
    • 2012
  • 최근들어 터널건설이 증가하고 있다. 이러한 터널건설 증가와 더불어 터널시공중 붕락발생 빈도도 증가하고 있다. 이와 비례하여 터널 입 출구부 사면부 변상 발생후 터널내부까지 과다변위를 발생시키는 사례 또한 자주 발생하고 있다. 따라서 본 연구에서는 터널시공 사례를 분석하여 갱구부 사면변상과 터널내부 변위를 발생시키는 요인들을 조사하였고 그중 특히 국부적인 단층파쇄대와 강우가 직접적인 붕락을 발생시키는 요인으로 분석되었다.

비선형 지진해석에 의한 PSC 격납건물의 지진취약도 분석 (Seismic Fragility Analysis of PSC Containment Building by Nonlinear Analysis)

  • 최인길;안성문;전영선
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.63-74
    • /
    • 2006
  • 원전 구조물 및 주요기기의 지진 안전성 평가에서는 내진성능을 정량화하는 방법으로 취약도 분석이 사용되고 있다. 지진취약도 분석은 격납건물의 설계 시 반영된 보수성을 배제한 실질적인 내진성능을 평가하는 것으로 이러한 보수성을 성능 및 응답에 관련된 확률론적 변수로 고려하여 평가하게 된다. 본 연구에서는 비선형 지진 해석으로부터 얻은 구조물의 변위응답을 기초로 한 지진취약도 분석 방법을 제시하였다. 또한 원전부지에서 선정된 발생가능한 근거리지진, 원거리지진, 설계지진 및 확률론적 시나리오지진을 시나리오지진으로 선정하고 이들 지진동에 대한 비선형 지진해석을 통하여 한국 표준형 원전 격납건물의 지진취약도를 평가하였다.

상판과 교대의 충돌을 고려한 사교의 비선형 지진거동 해석 (Nonlinear Seismic Behavior Analysis of Skewed Bridges Considering Pounding Between Deck and Abutment)

  • 강승우;최광규;송시영;손민규
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.301-310
    • /
    • 2016
  • There are differences in seismic behavior between non-skewed bridges and skewed bridges due to in-plane rotations caused by pounding between the skewed deck and its abutments during strong earthquake. Many advances have been made in developing design codes and guidelines for dynamic analyses of non-skewed bridges. However, there remain significant uncertainties with regard to the structural response of skewed bridges caused by unusual seismic response characteristics. The purpose of this study is performing non-linear time history analysis of the bridges using abutment-soil interaction model considering pounding between the skewed deck and its abutments, and analyzing global seismic behavior characteristics of the skewed bridges to assess the possibility of unseating. Refined bridge model with abutment back fill, shear key and elastomeric bearing was developed using non-linear spring element. In order to evaluate the amplification of longitudinal and transverse displacement response, non-linear time history analysis was performed for single span bridges. Far-fault and near-fault ground motions were used as input ground motions. According to each parameter, seismic behavior of skewed bridges was evaluated.

999번 지방도로 경상북도 안동시 위리 지역의 사면 변형 및 안정성 분석 (Analysis of Deformation and Stability of Slope at the Wiri Region of Local Road 999 Nearby Andong, Gyeongsangbukdo in Korea.)

  • 장현식;장보안
    • 지질공학
    • /
    • 제10권1호
    • /
    • pp.1-12
    • /
    • 2000
  • 경상북도 안동시 임동면에 위치한 999번 지방도로 위리 지역에 고개 마루를 절취하여 도로 개설공사를 시행한 후, 강우량이 많을 때 산측이 침하하고 도로가 융기하는 등 사면이 불안정하게 활동하였다. 이 연구에서는 위리 지역의 변형 발생의 원인을 분석하고, 수치해석을 통하여 연구지역 사면의 안정성을 평가하였다. 연구지역은 백악기 셰일, 이암 및 사암으로 구성되어 있으며, 북북서 및 북북동 방향의 두 개의 단층이 분포하고 있다. 사면의 변형은 지하수위의 증가에 따른 단층 점토의 전단강도 감소, 간극수압의 증가, 단위중량의 증가 등으로 인하여 단층을 따라 사면이 이동하면서 발생하며, 위의 여러 요인 중에서 단층 점토의 전단강도 감소가 사면의 변형에 가장 큰 요인으로 밝혀졌다. 사면의 안정성 및 변형정도를 파악하기 위하여 사면에 8개의 단면을 설정한 후 한계평형법, 유한 요소법 및 유한 차분법을 이용하여 해석을 실시하였다. 해석 결과, 지하수위가 단층면 아래에 분포할 때 안전율은 1.7 이상이지만, 지하수위가 지표면까지 상승하면 안전율은 1.0 이하로 감소하고, 15~30cm의 변위가 발생하는 것으로 해석되어 위리 지역에 발생한 변형과 거의 유사한 결과를 보여준다. 안정화 공사가 끝난 현재에는 지하수위가 지표면에 도달하여도 각 단면의 안전율은 2.4 이상이고 2.8cm이하의 변위가 발생하여, 이 지역의 사면은 매우 안정한 것으로 판단된다.

  • PDF