• Title/Summary/Keyword: Fault accidents

Search Result 176, Processing Time 0.092 seconds

Analysis of RCD'S Material Degradation by Weathering Test (내후성시험에 의한 누전차단기 재질변화 분석)

  • Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Yong, Shin-Jin;Kim, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • Fault rate of RCD is increasing due to deterioration and long period usage in domestic. According to Korean standards, the RCDs are installed in panel boards. When RCDs are installed at outdoor, the RCDs must be protected from uv, water etc. by using the housing. However, many RCDs are exposed to the external environment. As a results, many RCDs have malfunctions so that cause the electrical accidents. The RCDs manufactured by four makes were used as the sample to weathering test. Futhermore, those were analyzed the ingredients of RCD'S using SEM, EDX and FT-IR/TAR before and after weathering test.

The analysis for malfunction of elevator equipment by instantaneous power quality (순시전원품질 변화에 딱른 엘리베이터의 오동작에 관한 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Yi, Geon-Ho;Kim, Sun-Gu;Yoon, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.34-36
    • /
    • 2006
  • The number of confine-disease of elevator increases every year and then sudden rise, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. For confirmation those malfunction accident, we are measuring and analyzing power quality(Sag, Interruption, Harmonic) of the actual site and evaluated the performance for stop and stating by testing the two imitation test equipment with EN12016(2004) standard level. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

  • PDF

Optimal Reporting Stategy of an Insured -Dynamic Programming Approach-

  • Min, Jae-Hyung
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.15 no.1
    • /
    • pp.83-97
    • /
    • 1990
  • We consider an insured who wishes to determine his optimal reporting strategy over a given planning horizon, when he has option of reporting of not reporting his at-fault accidents. Assuming that the premium in future period is continually adjusted by the insured's loss experience, the insured would not report every loss incurred. Rather, considering the benefits and costs of each decision, the insured may want to seek a way of optimizing his interests over the planning horizon. The situation is modeled as a dynamic programming problem. We consider an insured's discounted expected cost minimization problem, where the premium increase in future period is affected by the size of the current claim. More specifically, we examine two cases ; (1) the premium increase in the next is a linear function (a constant fraction) of the current claim size; (2) the premium increase in the next period is a concave function of the current claim size. In each case, we derive the insured's optimal reporting strategy.

  • PDF

Safety Analysis on the Tritium Release Accidents

  • Yang, Hee joong
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.2
    • /
    • pp.96-107
    • /
    • 1991
  • At the design stage of a plant, the plausible causes and pathways of release of hazardous materials are not clearly known. Thus there exist large amount of uncertainties on the consequences resulting from the operation of a fusion plant. In order to better handle such uncertain circumstances, we utilize the Probabilistic Risk Assessment(PRA) for the safety analyses on fusion power plant. In this paper, we concentrate on the tritium release accident. We develop a simple model that describes the process and flow of tritium, by which we figure out the locations of tritium inventory and their vulnerability. We construct event tree models that lead to various levels of tritium release from abnormal initiating events. Branch parameters on the event tree are assessed from the fault tree analysis. Based on the event tree models we construct influence diagram models which are more useful for the parameter updating and analysis. We briefly discuss the parameter updating scheme, and finally develop the methodology to obtain the predictive distribution of consequences resulting from the operating a fusion power plant. We also discuss the way to utilize the results of testing on sub-systems to reduce the uncertain ties on over all system.

  • PDF

Development of the Risk Assessment Model for Train Collision and Derailment (열차 충돌/탈선사고 위험도 평가모델 개발)

  • Choi, Don-Bum;Wang, Jong-Bae;Kwak, Sang-Log;Park, Chan-Woo;Kim, Min-Su
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1518-1523
    • /
    • 2008
  • Train collision and derailment are types of accident with low probability of occurrence, but they could lead to disastrous consequences including loss of lives and properties. The development of the risk assessment model has been called upon to predict and assess the risk for a long time. Nevertheless, the risk assessment model is recently introduced to the railway system in Korea. The classification of the hazardous events and causes is the commencement of the risk assessment model. In previous researches related to the classification, the hazardous events and causes were classified by centering the results. That classification was simple, but might not show the root cause of the hazardous events. This study has classified the train collision and derailment based on the relevant hazardous event including faults of the train related the accidents, and investigates the causes related to the hazardous events. For the risk assessment model, FTA (fault tree analysis) and ETA (event tree analysis) methods are introduced to assess the risk.

  • PDF

The Study of Grid Fault Detection for Sag, Swell (Sag와 Swell에 따른 계통 이상 검출에 관한 연구)

  • Kim, Min-Gi;Noh, Yong-Su;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

The method of risk assessment by AMEA (AMEA을 활용한 위험성평가 방법)

  • Kim, Geon-Ho;Kwon, Sang-Myeon;Lee, Kang-Bok;Kim, Yoon-Sung;Lee, Jai-Won;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.97-111
    • /
    • 2007
  • In risk assessment, there are several methods such as Safety Review, Checklist, FMEA(Failure Mode and Effect Analysis), FTA(Fault Tree Analysis), ETA (Event Tree Analysis) etc, however, the level of accident is indentified by the probability of accident and severity resulting from accident which used widely in assessing accidents and disasters. In this paper, the risk assessment method to decide the level of risk will be introduced by using severity, frequency and detection according to accident theory.

Probabilistic Risk Assessment Techniques for the Risk Analysis of Construction Projects (건설공사의 위험도분석을 위한 확률적 위험도 평가)

  • 조효남;임종권;박영빈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.27-34
    • /
    • 1997
  • In this paper, systematic and comprehensive approaches are suggested for the application of quantitative PRA techniques especially for those risk events that cannot be easily evaluated quantitatively In addition, dominant risk events are identified based on their occurrence frequency assessed by both actual survey of construction site conditions and the statistical data related with the probable accidents. Practical FTA(Fault Tree Analysis) and ETA(Event Tree Analysis) models are used for the assessment of the identified risks. When the risk events are lack of statistical data, appropriate Bayesian models incorporating engineering judgement and test results are also introduced in this paper. Moreover, a fuzzy probability technique is used for the quantitative risk assessment of those risk components which are difficult to evaluate quantitatively.

  • PDF

A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF