• 제목/요약/키워드: Fault Simulation and Analysis

검색결과 416건 처리시간 0.023초

A Novel Fault Location Scheme on Korean Electric Railway System Using the 9-Conductor Representation

  • Lee, Chang-Mu;Lee, Han-Sang;Yoon, Dong-Hee;Lee, Han-Min;Song, Ji-Young;Jang, Gil-Soo;Han, Byung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.220-227
    • /
    • 2010
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because of long distance, 40[km] or above, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, it must be modeled exactly to analyze the fault current magnitude and fault location. In this paper, suggesting the novel scheme of fault location, a 9-conductor modeling technique including boost wires and impedance bonds is introduced based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and propose a powerful model for fault analysis on electric railway systems.

회전체 결함 진단을 위한 특징 파라미터 분석 (Feature Parameter Analysis for Rotor Fault Diagnosis)

  • 정래혁;채장범;이병학;이도환;이병곤
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.31-38
    • /
    • 2012
  • Rotor of rotating machinery is the highly damaged part. Fault of 7 different types was confirmed as the main causes of rotor damage from the pump failure history data in domestic and U.S. nuclear. For each fault types, simulation testing was performed and fault signals were collected form the sensors. To calculate the statistical parameters of time-domain & frequency-domain, measured signals were analyzed by using the discrete wavelet transform, fast fourier transform, statistical analysis. Total 84 parameters were obtained. And Effectiveness factor were used to evaluate the discrimination capacity of each parameter. From the effectiveness factor, RAW-P4/RAW-P7/WT2-NNL/WT2-EE/WT1-P1 showed high ranking. Finally, these parameters were selected as the feature parameters of intelligent fault diagnostics for rotor.

Differential Fault Analysis for Round-Reduced AES by Fault Injection

  • Park, Jea-Hoon;Moon, Sang-Jae;Choi, Doo-Ho;Kang, You-Sung;Ha, Jae-Cheol
    • ETRI Journal
    • /
    • 제33권3호
    • /
    • pp.434-442
    • /
    • 2011
  • This paper presents a practical differential fault analysis method for the faulty Advanced Encryption Standard (AES) with a reduced round by means of a semi-invasive fault injection. To verify our proposal, we implement the AES software on the ATmega128 microcontroller as recommended in the standard document FIPS 197. We reduce the number of rounds using a laser beam injection in the experiment. To deduce the initial round key, we perform an exhaustive search for possible key bytes associated with faulty ciphertexts. Based on the simulation result, our proposal extracts the AES 128-bit secret key in less than 10 hours with 10 pairs of plaintext and faulty ciphertext.

적응 자동 재폐로 및 고장거리 산정을 위한 새로운 1단자 알고리즘 (A New One Terminal Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation)

  • Zoran Radojevic;Joong-Rin Shin
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.438-445
    • /
    • 2004
  • This paper presents a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and fault distance calculation. Arc voltage amplitude and fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation and real field record are given.

Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.289-293
    • /
    • 2007
  • The fault current limiting characteristics of the separated and the integrated three-phase flux-lock type superconducting fault current limiters (SFCLs) were analyzed. The three-phase flux-lock type SFCL consisted of three flux-lock reactors and three $high-T_c$ superconducting (HTSC) elements. In the integrated three-phase flux-lock type SFCL, three flux-lock reactors are connected on the same iron core. On the other hand, three flux-lock reactors of the separated three-phase flux-lock type SFCL are connected on three separated iron cores. The integrated three-phase flux-lock type SFCL showed the different fault current limiting characteristics from the separated three-phase flux-lock type SFCL that the fault phase could affect the sound phase, which resulted in quench of the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the separated and the integrated three-phase flux-lock type SFCLs according to the ground fault types were compared.

Improved PCA method for sensor fault detection and isolation in a nuclear power plant

  • Li, Wei;Peng, Minjun;Wang, Qingzhong
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.146-154
    • /
    • 2019
  • An improved principal component analysis (PCA) method is applied for sensor fault detection and isolation (FDI) in a nuclear power plant (NPP) in this paper. Data pre-processing and false alarm reducing methods are combined with general PCA method to improve the model performance in practice. In data pre-processing, singular points and random fluctuations in the original data are eliminated with various techniques respectively. In fault detecting, a statistics-based method is proposed to reduce the false alarms of $T^2$ and Q statistics. Finally, the effects of the proposed data pre-processing and false alarm reducing techniques are evaluated with sensor measurements from a real NPP. They are proved to be greatly beneficial to the improvement on the reliability and stability of PCA model. Meanwhile various sensor faults are imposed to normal measurements to test the FDI ability of the PCA model. Simulation results show that the proposed PCA model presents favorable performance on the FDI of sensors no matter with major or small failures.

EMTDC를 이용한 고온초전도 저항형 한류기 모델링 (Modeling of HTS Resistive Superconducting Fault Current Limiter Using EMTDC)

  • 이재득;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.216-218
    • /
    • 2002
  • This study is the modeling of resistive type SFCLs. There was numerical modeling and simulation using EMTP in the conventional modeling of SFCL. The numerical modeling was presented an analysis of numerical characteristic of SFCL. And the modeling using EMTP was made up of the study for setting method of specific parameters of a SFCL. This paper proposes the model of resistive type superconducting fault current limiter using EMTDC(Electromagnetic transients for DC analysis program). The simulation schemes that can be applied to the utility network readily and cheaply under various conditions considering the sort of fault, the capacity of systems as well are strongly expected and emphasized among researchers.

  • PDF

A NEW APPROACH OF FAULT DETECTION BASED ON WAVEARX NEURAL NETWORK OBSERVER

  • Ma, Liling;Yang, Yinghua;Wang, Fuli
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2001년도 The Seoul International Simulation Conference
    • /
    • pp.116-122
    • /
    • 2001
  • A novel approach based on WaveARX neural network observer is proposed far the fault detect of a class of nonlinear systems which consist of known linear part and unknown nonlinear part. A linear observer is first designed, then a nonlinear compensation term in the nonlinear observer is estimated by using a deconvolution method. The WaveARX network is used to model the obtained compensation term. At last, the residual fur fault detection is generated based on the analysis of the upper bound approximate error. Simulation results have shown the feasibility and effectiveness of the method.

  • PDF

영구자석 동기 전동 시스템의 전기적 오류 분석을 위한 시뮬레이션 모델 개발 (Development of Simulation Model for Electrical Fault Analysis of PMSM Drive System)

  • 최진철;홍원복;이우택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.848-849
    • /
    • 2008
  • This paper presents a simulation model to analyze effects of electrical faults for the Permanent Magnet Synchronous Motor(PMSM) drive system. The major fault modes of system are investigated and an intuitive system model is developed using MATLAB/Simulink. The developed model provides useful environments to inject and remove the various faults. Simulation results show the dynamic performances of system during the transient state from normal to fault, and those will be a great help to make a system more reliable.

  • PDF

Fault Diagnosis of Power Converter for Switched Reluctance Motor based on Discrete Degree Analysis of Wavelet Packet Energy

  • Gan, Chun;Wu, Jianhua;Yang, Shiyou
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.336-341
    • /
    • 2013
  • Power converter plays a very important role in switched reluctance motor (SRM) systems, and it is also the easiest one to experience failures. Power converter faults will cause the motor to run in non equilibrium states, and a long time fault operation will lead to motor and other modules damaged, and make the system completely lose working stability. This paper uses an asymmetric bridge converter as the research object with three-phase SRM, employs the wavelet packet decomposition for the phase currents. It analyzes and studies the short circuit fault condition of IGBT, uses an energy discrete degree of the wavelet packet nodes as the fault characteristic, and conducts the corresponding experimental and simulation analysis to verify the effectiveness and practicality of the proposed method.