• 제목/요약/키워드: Fault Simulation and Analysis

검색결과 416건 처리시간 0.032초

게이트와 드레인/소오스 단락결함을 갖는 CMOS 회로의 스위치 레벨 결함 시뮬레이터 구현 (An Implementation of the switch-Level Fault Simulator for CMOS Circuits with a Gate-to-Drain/Source short Fault)

  • 정금섭;전흥우
    • 전자공학회논문지A
    • /
    • 제31A권4호
    • /
    • pp.116-126
    • /
    • 1994
  • In this paper, the switch-level fault simulator for CMOS circuits with a gate-to-drain/source short fault is implemented. A fault model used in this paper is based on the graphical analysis of the electrical characteristics of the faulty MOS devices and the conversion of the faulty CMOS circuit to the equivalent faulty CMOS inverter in order to find its effect on the successive stage. This technique is very simple and has the increased accuracy of the simulation. The simulation result of the faulty circuit using the implemented fault simulator is compared with the result of the SPICE simulation.

  • PDF

고온초전도 한류기의 전력계통 적용에 관한 연구 (A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter)

  • 배형택;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

배전시스템에서의 저항형 초전도 한류기 파라미터 산정방법 (Application Analysis of a Resistive type SFCL for Distribution Systems)

  • 허태전;배형택;박민원;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.28-31
    • /
    • 2004
  • Since the discovery of the high temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results. significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a distribution system are performed by the PSCAD/EMTDC-based simulation method in which a component for resistive type ot SFCL is presented. Through the simulation. the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended.

소프트웨어 오류 추정 기법을 활용한 공대지 사격 오류 요인 분석 모델 (The Fault Analysis Model for Air-to-Ground Weapon Delivery using Testing-Based Software Fault Localization)

  • 김재환;최경희;정기현
    • 한국시뮬레이션학회논문지
    • /
    • 제20권3호
    • /
    • pp.59-67
    • /
    • 2011
  • 본 논문에서는 오류 검출을 위해 소프트웨어 오류 추정 기법을 활용하여 항공무장 시스템인 공대지 사격의 오류 요인을 분석하기 위한 모델을 제시하고 모델을 기반으로 오류 요인 영향을 분석하였다. 선행 연구에서는 공대지 무기체계의 정확도에 영향을 미치는 오류 요소를 분석하고 결함위치추정 기법인 FBEL(Factor-based Error Localization) 기법을 제안하였으며 실사격 자료에 적용하여 오류 요소를 분석하였다. 그러나 다양한 요인 중 하나의 요인인 정확도를 고정하여 적용하므로 다양한 사격 정확도 변화에 따른 사격 오류 발생 요소와의 상관관계는 밝히지 못하였다. 본 연구에서는 사격 오류 요소의 상관관계 분석을 통하여 보다 세밀한 오류 분석 모델을 제시하고 시간과 비용이 제한적이거나 테스트 케이스가 적은 상태에서 오류 발생 가능 요소를 추정하는 방법을 제안한다. 제안된 방법은 실사격 자료를 이용한 시뮬레이션을 통해 그 효용성을 입증하였으며, 무기체계 공대지 시험평가에서 어떤 요소들이 정확도에 영향을 미치는 지를 분석하는데 성공적으로 활용될 수 있음을 보였다.

매입형 영구자석 동기전동기의 고장해석 및 시뮬레이션방법 (Faults Analysis and Dynamic Simulation Method for Interior PM Synchronous Motor)

  • 손도;이석희;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.874-875
    • /
    • 2007
  • This paper introduces major potential faults of IPMSM and their simulation realization methods. The faults of IPMSM, generally, contain single-phase open circuit, single-phase or 3-phase short circuit, and uncontrolled generation. When different fault occurs, the circuit of total system including motor and inverter also will be changed. Therefore, it is necessary to analyze and establish independent model for each kind of fault. In this paper, first, the drive circuit is analyzed as different fault type. Then, the corresponding simulation results solved in Simulink@MATLAB are given. The absence of experiment results leads that the veracity of simulation results can not be verified, but the tendency will be explained by theory analysis.

  • PDF

지중송전케이블 고장신호 처리를 위한 필터 설계 (Filter Design for Fault Location Detection on Underground Power Cable)

  • 이재덕;류희석;최상봉;남기영;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.361-363
    • /
    • 2003
  • To reduce the effect of fault on underground power cable, we need exact and fast fault location detection technique. In this thesis, we describe on filter design technique that can be applied to on-line fault defection technique. To design fitter for fault location defection on Power cable, we should analysis fault signal. So we designed test bed for fault generation and measured fault signals for analysis. Through the analysis of signals, we found that ANC filter can be applied to separate fault signals and we designed a ANC filter. We tested on the designed filter through computer simulation, and we describe its results in this paper.

  • PDF

상관분석법에 의한 선박기관실 고장진단 시스템 개발 (The Development of Diesel Engine Room Fault Diagnosis System Using a Correlation Analysis Method)

  • 김영일;오현경;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.253-259
    • /
    • 2006
  • There is few study which automatically diagnoses the fault from ship's monitored data. The bigger control and monitoring system is. the more important fault diagnosis and maintenance is to reduce damage caused by system fault. This paper proposes fault diagnosis system using a correlation analysis algorithm which is able to diagnose and forecast the fault from monitored data and is composed of fault detection knowledge base and fault diagnosis knowledge base. For all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem, To verify capability of fault detection, diagnosis and prediction, FMS(Fault Management System) is developed by C++. Simulation by FMS is carried out with population data set made by the log book data of 2 months duration from a large full container ship of H shipping company.

상관분석법에 의한 선박기관실 고장진단 시스템 개발 (The Development of Diesel Engine Room Fault Diagnosis SystemUsing a Correlation Analysis Method)

  • 김영일;오현경;천행춘;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.251-256
    • /
    • 2005
  • There is few study which automatically diagnose the fault from ship's monitored signal. The bigger control and monitoring system is, the more important fault diagnosis and maintenance is to reduce damage brought forth by system fault. This paper proposes fault diagnosis system using a correlation analysis algorithm which is able to diagnose and forecast the fault and is composed to fault detection knowledge base and fault diagnosis knowledge base. For this all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem by analyzing ship's operation data. To verifying capability of fault detection, diagnosis and prediction, Fault Management System(FMS) is developed by C++. Simulation experiment by FMS is carried out with population data set made by log book data of 2 months duration from a large full container ship of H shipping company.

  • PDF

유도 전동기 구동 시스템의 고장진단 (Fault Diagnosis for Induction Motor Drive System)

  • 김호근;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.154-156
    • /
    • 1993
  • In this paper, fault analysis using simulation method and fault diagnosis scheme are presented for induction motor drive system. Major faults such as inverter 'a' phase open fault, inverter 'a'-'b' phase short circuit fault and inverter 'a' phase ground fault are analyzed and simulated. On-line and off-line fault diagnosis systems are proposed.

  • PDF

Seismic response of nuclear containment structures due to recorded and simulated near-fault ground motions

  • Kurtulus Soyluk;Hamid Sadegh-Azar;Dersu Yilmaz
    • Structural Engineering and Mechanics
    • /
    • 제87권5호
    • /
    • pp.431-450
    • /
    • 2023
  • In this study, it is intended to perform nonlinear time-history analyses of nuclear power plant structures (NPP) under near-fault earthquakes showing directivity pulse and fling-step characteristics. Simulation procedures based on cycloidal pulse and far-fault ground motions are also used to simulate near-fault motions showing forward-directivity and fling-step characteristics and the structural responses are compared with those of the recorded near-fault ground motions. Because it is aimed to determine specifically the pulse type characteristics of near-fault ground motions on NPPs, all the ground motions are normalized to have a PGA of 0.3 g. Depending on the obtained results it can be underlined that although near-fault ground motion has the potential to cause damage mostly on structural systems having larger periods, it may also have noticeable effects on the responses of rigid structures, like NPP containment buildings. On the other hand, simulated near-fault motions can help us to get an insight into the near-fault mechanism as well as an approximate visualization of the structural responses under near-fault earthquakes.