• Title/Summary/Keyword: Fault Mode

Search Result 327, Processing Time 0.025 seconds

Development of Maintenance Sequence System by Using Modified FMEA and CBR (FMEA 개념과 사례베이스추론 기법을 이용한 보전작업순서결정시스템의 개발)

  • 김광만
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.4
    • /
    • pp.103-112
    • /
    • 2001
  • In Factory, as the number of machine is increased the more maintenance efforts are necessary. Multi maintenance issues may occur at a certain time and the determination of maintenance sequence is needed. In this study, we first compare the priority of machines and the impact value using modified FMEA(Failure Mode Effect and Analysis) method. Also, CBR(Case-based Reasoning) approach is applied to retrieve similar fault cases of current machine problem. The proposed methodology will be useful to implement decision support system of maintenance sequence for CMMS/EAM (Computerized Maintenance Management System/Enterprise Asset Management).

  • PDF

A Pulsed Mode Operating DC Power Supply Based on Modified Multilevel Converter (Modified 멀티레벨 컨버터 기반 펄스모드 동작 직류전원장치)

  • Ahn J.S.;Nho E.C.;Kim I.D.;Kim H.G.;Chun T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.264-268
    • /
    • 2003
  • This paper describes a high voltage high power DC power supply which has the ability of pulsed mode operation. The power supply Is constructed with several series connected power converters based on modified multilevel converters. The modified multilevel converters are suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis, simulations, and experiments are carried out to Investigate the operation and usefulness of the proposed scheme.

  • PDF

Selection of Single Point Vulnerability through the Failure Mode Effect Analysis of Equipment in Newly built Nuclear Power Plant (신규원전의 기기별 고장분석을 통한 발전정지유발기기 선정)

  • Hyun, Jin-Woo;Yeom, Dong-Un;Song, Tae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.509-512
    • /
    • 2012
  • For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. Newly built Nuclear Power Plants need to develop the SPV list, so performed the job which analyse equipment failure effect for SPV selection for 1 year. To develop this, Failure Mode Effect Analysis(FMEA) and Fault Tree Analysis(FTA) methods are used. As results of this analysis, about 900 equipment are selected as SPV. Thereafter those are going to be applied to Nuclear Power Plants to enhance equipment reliability.

Seamless Transfer Control of Grid-Connected Type PCS between Current and Voltage Modes (계통 연계형 PCS의 전류모드와 전압모드 전환제어)

  • Jung, J.H.;Sun, R.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.35-36
    • /
    • 2010
  • This paper describes a new method for the seamless operation mode transfer of a PCS. The proposed method provides reduced STS turn off time after line fault and smooth mode change between current and voltage control of the PCS. The usefulness of the method is verified through simulations.

  • PDF

Dynamic characteristic for vibration mount of MG-Set (전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명)

  • Yoo, Musang;Oh, Kyonghan;Joo, Ingouk;Kim, Hyojin;Roh, Cheolwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

The Study on the Characteristics and Design Method of High-Tc Superconducting Persistent Current Switch (고온초전도 영구전류스위치의 특성 및 설계에 관한 연구)

  • 박상건;강형구;배덕권;윤용수;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.216-219
    • /
    • 2003
  • Persistent Current Switch (PCS) is used in many superconducting magnet system. To apply the high-Tc superconductor in superconducting machine such as motor, generator, MAGLEV, MRI and NMR, the study on the persistent current mode should be performed. Because persistent current mode provide best stability and homogeneous characteristics to the superconducting machine. To stabilize the superconductor system, it is important to estimate the length of PCS. If the proper length of PCS is too short, it cause serious injury to system in fault state. So we calculated the optimal length of PCS in this paper.

  • PDF

Actuator Failure Diagnosis and Accommodation Using Sliding Mode Control for Submersible Vehicle (슬라이딩 모드 제어기를 이용한 수중운동체 엑추에이터 고장진단 및 대처)

  • Yang, In-Seok;Kim, Young-Jin;Lee, Dong-Ik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.7
    • /
    • pp.661-667
    • /
    • 2010
  • This paper presents a failure diagnosis and accommodation strategy which is capable of tolerating faulty actuators of a submersible vehicle. The proposed method is mainly based on a sliding mode control technique. The primary ideas include a performance index to describe the effectiveness of actuators, and a controller reconfiguration strategy using the actuator effectiveness index. The actuator effectiveness proposed in this work is defined as the relationship between the sliding surface and the controlled system behavior. The resulting actuator effectiveness is then used in reconfiguring the controller in order to counteract for the deteriorated control performance in the presence of a faulty actuator. The effectiveness of the proposed method is demonstrated by means of numerical simulations with a submersible vehicle.

Performance Analysis of a Sliding Mode Control for Distributed Generations

  • Islam, Gazi;Al-Durra, Ahmed;Muyeen, S.M.;Caruna, Cedric;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.98-104
    • /
    • 2014
  • This paper presents the performance analysis of a sliding mode based hybrid controller for three phase voltage source inverter. The main objective of this analysis is to observe the effectiveness of the controller for fault ride through (FRT) capability improvement of the distributed generations (DG). The performance of the conventional PI based cascaded controller is also presented for comparison purpose.

A Study on the Analysis Model of AC/DC Switch-mode Converter (AC/DC 스위치모드 컨버터의 해석모델에 관한 연구)

  • 오인석;박한웅;박진규;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.70-76
    • /
    • 1998
  • A switch-mode AC/DC converter with high input power factor and sinusoidal input current waveforms is analyzed and modelled for computer simulation. The developed mathematical model for this converter can be used to examine the transient and steady-state performance for selecting the proper ratings of filter, boost inductor and semiconductor devices or the effects of this converter under normal and fault operating conditions on the associated power systems. The proposed model and computer programs are confirmed by comparing with the experimental results.

The Study of Grid Fault Detection for Sag, Swell (Sag와 Swell에 따른 계통 이상 검출에 관한 연구)

  • Kim, Min-Gi;Noh, Yong-Su;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF