• Title/Summary/Keyword: Fault Injection Analysis

Search Result 65, Processing Time 0.02 seconds

FAULT DETECTION COVERAGE QUANTIFICATION OF AUTOMATIC TEST FUNCTIONS OF DIGITAL I&C SYSTEM IN NPPS

  • Choi, Jong-Gyun;Lee, Seung-Jun;Kang, Hyun-Gook;Hur, Seop;Lee, Young-Jun;Jang, Seung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.421-428
    • /
    • 2012
  • Analog instrument and control systems in nuclear power plants have recently been replaced with digital systems for safer and more efficient operation. Digital instrument and control systems have adopted various fault-tolerant techniques that help the system correctly and safely perform the specific required functions regardless of the presence of faults. Each fault-tolerant technique has a different inspection period, from real-time monitoring to monthly testing. The range covered by each faulttolerant technique is also different. The digital instrument and control system, therefore, adopts multiple barriers consisting of various fault-tolerant techniques to increase the total fault detection coverage. Even though these fault-tolerant techniques are adopted to ensure and improve the safety of a system, their effects on the system safety have not yet been properly considered in most probabilistic safety analysis models. Therefore, it is necessary to develop an evaluation method that can describe these features of digital instrument and control systems. Several issues must be considered in the fault coverage estimation of a digital instrument and control system, and two of these are addressed in this work. The first is to quantify the fault coverage of each fault-tolerant technique implemented in the system, and the second is to exclude the duplicated effect of fault-tolerant techniques implemented simultaneously at each level of the system's hierarchy, as a fault occurring in a system might be detected by one or more fault-tolerant techniques. For this work, a fault injection experiment was used to obtain the exact relations between faults and multiple barriers of faulttolerant techniques. This experiment was applied to a bistable processor of a reactor protection system.

Fault Diagnosis Method of Permanent Magnet Synchronous Motor for Electrical Vehicle

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.413-420
    • /
    • 2016
  • The permanent magnet synchronous motor has high efficiency driving performance and high power density output characteristics compared with other motors. In addition, it has good regenerative operation characteristics during braking and deceleration driving condition. For this reason, permanent magnet synchronous motor is generally applied as a power train motor for electrical vehicle. In permanent magnet synchronous motor, the most probable causes of fault are demagnetization of rotor's permanent magnet and short of stator winding turn. Therefore, the demagnetization fault of permanent magnet and turn fault of stator winding should be detected quickly to reduce the risk of accident and to prevent the progress of breakdown of power train system. In this paper, the fault diagnosis method using high frequency low voltage injection was suggested to diagnose the demagnetization fault of rotor permanent magnet and the turn fault of stator winding. The proposed fault diagnosis method can be used to check the faults of permanent magnet synchronous motor during system check-up process at vehicle starting and idling stop mode. The feasibility and usefulness of the proposed method were verified by the finite element analysis.

Analysis of Risk Control Options for Blockage Treatment (Subsea X-mas Tree에서의 Blockage 처리 실패에 대한 위험도 저감 방안 분석)

  • Yoo, Won-Woo;Park, Min-Sun;Yang, Young-Soon
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.47-52
    • /
    • 2013
  • A subsea chemical injection system treats blockage problems in a subsea production system. It is important to treat problems quickly, because production delays cause fatal profit losses in a subsea production system. Therefore, the subsea industry requires a relatively higher reliability level for a production system compared to other industries. In this study, a subsea chemical injection system (linked to a control system) to inject chemicals into a subsea X-mas tree was analyzed. By using FSA (Formal Safety Assessment), the risk factors were defined and a quantitative risk analysis utilizing FTA (Fault Tree Analysis) and ETA (Event Tree Analysis) was performed. As a result, the effectiveness of a risk reduction option was evaluated.

Cryptanalysis using Fault Injection and Countermeasures on DSA (오류주입을 이용한 DSA 서명 알고리즘 공격 및 대응책)

  • Jung, Chul-Jo;Oh, Doo-Hwan;Choi, Doo-Sik;Kim, Hwan-Koo;Ha, Jae-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.3045-3052
    • /
    • 2010
  • The international standard signature algorithm DSA has been guaranteed its security based on discrete logarithm problem. Recently, the DSA was known to be vulnerable to some fault analysis attacks in which the secret key stored inside of the device can be extracted by occurring some faults when the device performs signature algorithm. After analyzing an existing fault attack presented by Bao et al., this paper proposed a new fault analysis attack by disturbing the random number. Furthermore, we presented a countermeasure to compute DSA signature that has its immunity in the two types of fault attacks. The security and efficiency of the proposed countermeasure were verified by computer simulations.

A Round Reduction Attack on Triple DES Using Fault Injection (오류 주입을 이용한 Triple DES에 대한 라운드 축소 공격)

  • Choi, Doo-Sik;Oh, Doo-Hwan;Bae, Ki-Seok;Moon, Sang-Jae;Ha, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.2
    • /
    • pp.91-100
    • /
    • 2011
  • The Triple Data Encryption Algorithm (Triple DES) is an international standard of block cipher, which composed of two encryption processes and one decryption process of DES to increase security level. In this paper, we proposed a Differential Fault Analysis (DFA) attack to retrieve secret keys using reduction of last round execution for each DES process in the Triple DES by fault injections. From the simulation result for the proposed attack method, we could extract three 56-bit secret keys using exhaustive search attack for $2^{24}$ candidate keys which are refined from about 9 faulty-correct cipher text pairs. Using laser fault injection experiment, we also verified that the proposed DFA attack could be applied to a pure microprocessor ATmega 128 chip in which the Triple DES algorithm was implemented.

Improved Shamir's CRT-RSA Algorithm: Revisit with the Modulus Chaining Method

  • Lee, Seungkwang;Choi, Dooho;Choi, Yongje
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.469-478
    • /
    • 2014
  • RSA signature algorithms using the Chinese remainder theorem (CRT-RSA) are approximately four-times faster than straightforward implementations of an RSA cryptosystem. However, the CRT-RSA is known to be vulnerable to fault attacks; even one execution of the algorithm is sufficient to reveal the secret keys. Over the past few years, several countermeasures against CRT-RSA fault attacks have tended to involve additional exponentiations or inversions, and in most cases, they are also vulnerable to new variants of fault attacks. In this paper, we review how Shamir's countermeasure can be broken by fault attacks and improve the countermeasure to prevent future fault attacks, with the added benefit of low additional costs. In our experiment, we use the side-channel analysis resistance framework system, a fault injection testing and verification system, which enables us to inject a fault into the right position, even to within $1{\mu}s$. We also explain how to find the exact timing of the target operation using an Atmega128 software board.

Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2) (스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2))

  • Park, Jung-Wook;Guglielmi, Yves;Graupner, Bastian;Rutqvist, Jonny;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.197-213
    • /
    • 2019
  • We simulated the fault reactivation experiment conducted at 'Main Fault' intersecting the low permeability clay formations of Mont Terri Underground Research Laboratory in Switzerland using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. We formulate the hydro-mechanical coupling relation of hydraulic aperture to consider the elastic fracture opening and failure-induced dilation for reproducing the abrupt changes in injection flow rate and monitoring pressure at fracture opening pressure. A parametric study was conducted to examine the effects of in-situ stress condition and fault deformation and strength parameters and to find the optimal parameter set to reproduce the field observations. In the best matching simulation, the fracture opening pressure and variations of injection flow rate and monitoring pressure showed good agreement with field experiment results, which suggests the capability of the numerical model to reasonably capture the fracture opening and propagation process. The model overestimated the fault displacement in shear direction and the range of reactivated zone, which was attributed to the progressive shear failures along the fault at high injection pressure. In the field experiment results, however, fracture tensile opening seems the dominant mechanism affecting the hydraulic aperture increase.

Differential Fault Analysis of the Block Cipher LEA (블록 암호 LEA에 대한 차분 오류 공격)

  • Park, Myungseo;Kim, Jongsung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1117-1127
    • /
    • 2014
  • Differential Fault Analysis(DFA) is widely known for one of the most powerful method for analyzing block cipher. it is applicable to block cipher such as DES, AES, ARIA, SEED, and lightweight block cipher such as PRESENT, HIGHT. In this paper, we introduce a differential fault analysis on the lightweight block cipher LEA for the first time. we use 300 chosen fault injection ciphertexts to recover 128-bit master key. As a result of our attack, we found a full master key within an average of 40 minutes on a standard PC environment.

Case Study of Electronic Fuel Injection Powertrain System FMEA Using Model-Based Fault Injection technique (모델 기반 결함 주입 기법을 이용한 Electronic Fuel Injection 전장 시스템 FMEA 사례연구)

  • Ye-ju Kim;Ye-won Na;Dong-min Lee;Ju-Young Kim;Jong-whoa Na
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.436-446
    • /
    • 2023
  • In the field of safety-critical systems, analyzing the effects of various failure factors (failure modes) is essential through Failure Mode and Effects Analysis (FMEA). However, with the increasing importance of software in systems, applying FMEA analysis to the design phase has become challenging. This paper proposes the use of Automatic FMEA, which can automatically perform FMEA using model-based design techniques, and presents a case study of FMEA for automotive engines. A comparison is made between the model-based Automatic FMEA analysis tool and existing FMEA tools. The study aims to demonstrate the performance of the Automatic FMEA analysis tool and propose future research plans.

Study of Electronic Hardware Integrated Failure Rate: Considering Physics of Failure Rate and Radiation Failures Rate (물리 고장률과 방사선 고장률을 반영한 전자 하드웨어 통합 고장률 분석 연구)

  • Dong-min Lee;Chang-hyeon Kim;Kyung-min Park;Jong-whoa Na
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.2
    • /
    • pp.216-224
    • /
    • 2024
  • This paper presents a method for analyzing the reliability of hardware electronic equipment, taking into account failures caused by radiation. Traditional reliability analysis primarily focuses on the wear out failure rate and often neglects the impact of radiation failure rates. We calculate the wear out failure rate through physics of failure analysis, while the radiation failure rate is semi-empirically estimated using the Verilog Fault Injection tool. Our approach aims to ensure reliability early in the development process, potentially reducing development time and costs by identifying circuit vulnerabilities in advance. As an illustrative example, we conducted a reliability analysis on the ISCAS85 circuit. Our results demonstrate the effectiveness of our method compared to traditional reliability analysis tools. This thorough analysis is crucial for ensuring the reliability of FPGAs in environments with high radiation exposure, such as in aviation and space applications.