정렬불량 진단을 위한 유전알고리듬 기반 특징분석 (Feature Analysis based on Genetic Algorithm for Diagnosis of Misalignment)

  • 하정민;안병현;유현탁;최병근
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.189-194
    • /
    • 2017
  • An compressor that is combined with the rotor and pneumatic technology has been researching for the performance of pressure. However, the control of operations, an accurate diagnosis and the maintenance of compressor system are limited though the simple structure of compressor and compression are advantaged to reduce the energy. In this paper, the characteristic of the compressor operating under the normal or abnormal condition is realized. and the efficient diagnosis method is proposed through feature based analysis. Also, by using the GA (genetic algorithm) and SVM (support vector machine) of machine learning, the performance of feature analysis is conducted. Different misalignment mode of learning data for compressor is evaluated using the fault simulator. Therefore, feature based analysis is conducted considering misalignment mode of the compressor and the possibility of a diagnosis of misalignment is evaluated.

Piezoelectric friction dampers for earthquake mitigation of buildings: design, fabrication, and characterization

  • Chen, Genda;Garrett, Gabriel T.;Chen, Chaoqiang;Cheng, Franklin Y.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.539-556
    • /
    • 2004
  • In this paper, the design, fabrication and characterization of a piezoelectric friction damper are presented. It was sized with the proposed practical procedure to minimize the story drift and floor acceleration of an existing 1/4-scale, three-story frame structure under both near-fault and far-field earthquakes. The design operation friction force in kip was numerically determined to range from 2.2 to 3.3 times the value of the peak ground acceleration in g (gravitational acceleration). Experimental results indicated that the load-displacement loop of the damper is nearly rectangular in shape and independent of the excitation frequency. The coefficient of friction of the damper is approximately 0.85 when the clamping force on the damper is above 400 lbs. It was found that the friction force variation of the damper generated by piezoelectric actuators with 1000 Volts is approximately 90% of the expected value. The properties of the damper are insensitive to its ambient temperature and remain almost the same after being tested for more than 12,000 cycles.

실 변수 엘피트주의 유전알고리즘을 이용한 SVC 계통의 안정화 장치의 설계 (A Design of Power System Stabilization for SVC System Using a RVEGA)

  • 정형환;허동렬;이정필;왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권7호
    • /
    • pp.324-332
    • /
    • 2001
  • In this paper, it is suggested that the selection method of parameter of Power System Stabilizer(PSS) with robustness in low frequency oscillation for Static VAR Compensator(SVC) using a Real Variable Elitism Genetic Algorithm(RVEGA). A SVC, one of the Flexible AC Transmission System(FACTS), constructed by a fixed capacitor(FC) and a thyristor controlled reactor(TCR), is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage. The proposed PSS parameters are optimized using RVEGA in order to maintain optimal operation of generator under the various operating conditions. To decrease the computational time, real variable string is adopted. To verify the robustness of the proposed method, we considered the dynamic response of generator speed deviation and generator terminal voltage by applying a power fluctuation and three-phase fault at heavy load, normal load and light load. Thus, we prove the usefulness of proposed method to improve the stability of single machine-infinite bus with SVC system.

  • PDF

터빈 블레이드 모델링을 통한 터빈 발전기 축 시스템의 기계적 토크 응답 분석 (Analysis of Turbine-Generator Shaft System Mechanical Torque Response based on Turbine Blade Modeling)

  • 박지경;정세진;김철환
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1269-1275
    • /
    • 2015
  • Turbine-generator torsional response is caused by interaction between electrical transient air-gap torque and mechanical characteristics of turbine-generator shafts. There are various factors that affects torsional interaction such as fault, circuit breaker switching and generator mal-synchronizing, etc. Fortunately, we can easily simulate above torsional interaction phenomena by using ElectroMagnetic Transient Program (EMTP). However, conventional EMTP shows the incomplete response of super- synchronous torsional mode since it does not consider turbine blade section. Therefore, in this paper, we introduced mechanical-electrical analogy for detailed modeling of turbine-generator shaft system including low pressure turbine blade section. In addition, we derived the natural frequencies of modeled turbine-generator shaft system including turbine blade section and analyzed the characteristics of mechanical torque response at shaft coupling and turbine blade root area according to power system balanced/unbalanced faults.

ASIC의 BIST 할당을 위한 효과적인 BILBO 설계 (Design on the efficient BILBO for BIST allocation of ASIC)

  • 이강현
    • 전자공학회논문지C
    • /
    • 제34C권9호
    • /
    • pp.53-60
    • /
    • 1997
  • In this paper, an efficient BILBO(named EBILBO) is proposed for batch testing application when a BIST (built-in self test) circuit is implemented on ASIC. In a large and complex circuit, the proposed algorithm of batch testing has one pin-count that can easily control 4 test modes in the normal speed of circuit operation. For the implementation of the BIST cifcuit, the test patern needed is generated by PRTPG(pseudo-random test pattern generator) and the ouput is observed by proposed algorithm is easily modified, such as the modelling of test pattern genration, signature EBILBO area and performance of the implemented BIST are evaluated using ISCAS89 benchmark circuits. As a resutl, in a circuit above 600 gates, it is confirmed that test patterns are genrated flexibly about 500K as EBILBO area is 59%, and the range of fault coverage is from 88.3% to 100%. And the optimized operation frequency of EBILBO designed and the area are 50MHz and 150K respectively. On the BIST circit of the proposed batch testing, the test mode of EBILBO is able to execute as realtime that has te number of s$\^$+/n$\^$+/(2s/2p-1) clocks simultaneously with the normal mode of circuit operation. Also the proposed algorithm is made of the library with VHDL coding thus, it will be widely applied to DFT (design for testability) that satisfies the design and test field.

  • PDF

풍력발전 한계운전용량에 대한 계통영향 분석 (Analysis of effect on power system considering the maximum penetration limit of wind power)

  • 명호산;김봉언;김형택;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.19-25
    • /
    • 2012
  • About supply and demand to see that you need to match, the limitations of wind power capacity is low demand and the commitment of the general generator will exist between the minimum generation. if the turbine's output can be controlled, The limitation of wind power capacity will be adopted based on instant power generation. Namely, The minimum limits of wind power generation based load operation by calculating the amount that is higher than if the output should be restricted to highest operation. in this paper, we committed to the demand for low enough that the combination of the general generator of wind power capacity to accommodate the operation of determining whether the limit is intended to. For this, power system analysis program PSS/E was used, Jeju system by implementing the model simulations were performed.

전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법 (High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults)

  • 최형진;송승호;정승기;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

고효율 DC/DC 컨버터용 전류분할과 시분할 스위치 비교 연구 (Comarative Study on Current or Time Sharing Switches for High Efficiency DC/DC Converter)

  • 고성훈;조성필;이수원;이성룡
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.68-75
    • /
    • 2012
  • This paper presents a comparative analysis of the parallel operation of different switches in a DC/DC converter. In high power applications, multi-switch PWM power conditioners may be preferred despite a higher component count, due to the absence of low frequency filters, reduced switching losses and fault tolerance. The paper demonstrates how current sharing (CSH) and time sharing (TSH) lead to the reduction of switching stress in the parallel operation of switches in any converter. The solutions proposed in this study can be applied on different scales to other power conditioners for DC/DC converter systems. Discussions of the concepts, hypotheses and computer simulations are verified by 1 kW experimental results.

고온 초전도 케이블 고장점 탐지를 위한 EMTP 시뮬레이션 및 분석 (EMTP Simulations and Analysis for Detection of Fault Location in High Temperature Superconducting Cables)

  • 방수식;장승진;이건석;권구영;이영호;황민제;손송호;박기준;신용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.357-358
    • /
    • 2015
  • 본 논문에서는 고온 초전도 케이블 고장점 탐지를 위해 시간-주파수 반사파 계측법(Time-Frequency Domain Reflectometry)을 적용하여 EMTP 시뮬레이션을 수행하고, 고온 초전도 케이블에 적합한 가우시안 첩 포락선 선형 기준 신호를 제시하였다. 고온 초전도 케이블을 EMTP로 모델링하여 TFDR 기법을 통해 케이블의 종단점을 추정하고 기준 신호의 전파 속도를 계산하였다. EMTP를 활용하여 국부적 결함이 발생한 고온 초전도 케이블을 모델링하였고, 결함 발생 케이블의 고장점 탐지 시뮬레이션 결과를 확인하였다.

  • PDF

엔진 양산라인의 충격성 불량유형 신호 진단을 위한 진단시스템 개발 (Diagnostic System for Crashing and Damping Signals in Engine-Assembly Line)

  • 오세도;김영진;서해윤;이태휘;이재원
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.965-970
    • /
    • 2011
  • 본 연구를 통하여 개발하고자 하는 진단시스템은 자동차 엔진 어셈블리라인에서 발생될 수 있는 특정 조립 불량유형을 검사하는 시스템이다. 대상으로 하는 불량 유형은 엔진 고장의 유형 중 커다란 충격성신호가 발생한 후, 보상적인 작은 충격파가 주기적으로 발생되는 형태이다. 이러한 불량유형을 기존의 시간영역분석 진단, 주파수분석, 통계적분석등에 의해 진단할 경우 한계점이 존재한다. 이에 웨이블릿 잡음 제거 전처리 방법, 피크검지 알고리즘, 불순도 최소값 선택 분할 방법을 이용한 새로운 유형의 이상진단 방법을 개발하는 연구를 진행하였다.