1 |
Akbay, Z. and Aktan, H.M. (1990), "Intelligent energy dissipation devices", Proc. 4th U.S. National Conf.
Earthquake Engrg., May 20-24, Palm Springs, CA, 427-435.
|
2 |
Dowdell, D.J. and Cherry, S. (1994), "Semi-active friciton dampers for seismic response control of structures",Proc. 5th U.S. National Conf. Earthquake Engrg., July 10-14, Chicago, IL.
|
3 |
Garrett, G.T. (2002), "Experimental characterization of a piezoelectric friction damper", M.S. Thesis, Universityof Missouri-Rolla.
|
4 |
Meltzler, A.H. et al. (1988), IEEE Standard on Piezoelectricity, ANSI/IEEE Std 176 1987, Institute of Electricaland Electronics Engineers, NY.
|
5 |
O'Neil, C. (2000), "Selected piezoelectric materials and their properties", Kinetic Ceramics, Inc., PersonalCommunication.
|
6 |
Inaudi, J.A. (1997), "Modulated homogeneous friction: a semi-active damping strategy", Earthq. Engrg. Struct.Dyn. 26, 361-376.
DOI
ScienceOn
|
7 |
Mitrovic, M., Carman, G.P. and Straub, F.K. (2000), "Electro-mechanical characterization of piezoelectric stackactuators", Proc. SPIE's 7th Int. Symp. on Smart Struct. and Mater., March 5-9, Newport Beach, CA.
|
8 |
Hirai, J., Naruse, M. and Abiru, H. (1996), "Structural control with variable friction damper for seismicresponse", Proc. 11th World Conf. Earthq. Engrg., June 23-28, Acapulco, Mexico.
|
9 |
Chen, Genda and Chen, Chaoqiang. (2002a), "Control of plastic deformation of steel moment-resisting framestructures with active friction dampers", Proc. 7th U.S. National Conf. Earthquake Engrg., July 21-25, Boston,MA.
|
10 |
Housner, G.W. et al. (1997), "Structural control: past, present, and future", J. Engrg. Mech., ASCE, 123(9), 897-971.
DOI
|
11 |
Kannan, S., Uras, H.M. and Aktan, H.M. (1995), "Active control of building seismic response by energydissipation", Earthq. Engrg. Struct. Dyn., 24, 747-759.
DOI
ScienceOn
|
12 |
Chen, Chaoqiang and Chen, Genda. (2002b), "Nonlinear control of a 20-story steel building with activepiezoelectric friction dampers", Int. J. Struct. Engrg. Mech., 14(1), 21-38.
DOI
ScienceOn
|
13 |
Chen, Genda and Chen, Chaoqiang. (2000), "Behavior of piezoelectric friction dampers under dynamic loading",Proc. SPIE's 7th Int. Symp. on Smart Struct. and Mater., March 5-9, Newport Beach, CA.
|
14 |
Chen, Genda and Chen, Chaoqiang. (2002c), "Building hazard mitigation with piezoelectric friction dampers",Proc. Int. Conf. Adv. Bldg. Tech., Dec. 4-6, Hong Kong.
|
15 |
Soong, T.T. and Dargush, G.F. (1997), Passive Energy Dissipation Systems in Structural Engineering, JohnWiley & Sons, UK.
|
16 |
Tian, P. (1997), "Generalized optimal control of elastic and inelastic structures subjected to earthquakeexcitation", Doctoral Dissertation, University of Missouri-Rolla.
|