• 제목/요약/키워드: Fault Frequency

검색결과 604건 처리시간 0.022초

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

속도 오차 외란이 반작용 휠 제어에 미치는 영향에 관한 실험적 연구 (Experimental Study on Effects of Speed Error Disturbance on Reaction Wheel Control)

  • 김지철;이형준;유지훈;오화석
    • 항공우주시스템공학회지
    • /
    • 제10권1호
    • /
    • pp.95-102
    • /
    • 2016
  • There are many possible disturbance sources on such a spacecraft, but reaction wheel assembly (RWA) which is generally used for spacecraft attitude control is anticipated to be the largest. These effects on degradation of performance of spacecraft such as attitude stability. In reaction wheel, disturbance caused by imbalance and speed error. It is hard to emulate speed error disturbance because it is not coincide with wheel frequency. This paper concentrates on emulating and analyzing the speed error disturbance. Firstly, classify the causes that lead to speed error disturbance which generate RPM fluctuation. Secondly, simulated with disturbance driver module and reaction wheel assembly which are developed by Spacecraft Control Lab. Experimental investigations have been carried out to test the disturbance emulator module as a disturbance generator for RWA. Measurements and test have been conducted on various fault. Frequency analysis of test data show that speed error disturbance effects on wheel settling wheel speed or fluctuation type.

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

레이저 유도 초음파를 이용한 재료평가 및 비파괴 검사 시스템 개발에 관한 연구 (The Study on the Material Evaluation and Development of Nondestructive Inspection System Using Laser Guided Ultrasonics)

  • 김재열;송경석;김창현;김유홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2004
  • In the present study, a Nd;YAG Laser (pulse type) was used to emit ultrasonic signals to a test material. In addition, a total ultrasonic investigation system was designed by adopting a Fabry-Perot interferometer, which receives ultrasonic signals without any contact. For non-destructive test SM45C, which contains some flaws was used as a test material. Because it is easy to align light beam in receiver, and the length of the light beam does not change much even if convex mirror leans towards one side, confocal Fabry-Perot interferometer, which has stable frequency, and PI control are used to correct interfered and unstable signals from temperature, fluctuation and time shift of laser frequency. Stable signals are always obtained by the feedback of PI circuit signals in the confocal Fabry-Perot interferometer. The type, size and position of flaws inside the test material were examined by achieving the stabilization of an interferometer. This study presented a useful method, which could quantitatively investigate the fault of objects by using a Fabry-Perot interferometer.

  • PDF

Microphone Array를 이용한 고압설비의 고장위치인식 알고리즘 (An Accidental Position Detection Algorithm for High-Pressure Equipment using Microphone Array)

  • 김득권;한순신;하현욱;이장명
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2300-2307
    • /
    • 2008
  • This study receives the noise transmitted in a constant audio frequency range through a microphone array in which the noise(like grease in a pan) occurs on the power supply line due to the troublesome partial discharge(arc). Then by going through a series of signal processing of removing noise, this study measures the distance and direction up to the noise caused by the troublesome partial discharge(arc) and monitors the result by displaying in the analog and digital method. After these, it determines the state of each size and judges the distance and direction of problematic part. When the signal sound transmitted by the signal source of bad insulator is received on each microphone, the signal comes only in the frequency range of 20 kHz by passing through the circuit of amplification and 6th low pass filter. Then, this signal is entered in a digital value of digital signal processing(TMS320F2812) through the 16-bit A/D conversion. By doing so, the sound distance, direction and coordinate of bad insulator can be detected by realizing the correlation method of detecting the arriving time difference occurring on each microphone and the algorithm of detecting maximum time difference.

Influence of Different Frequency Harmonic Generated by Rectifier on High-speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Yang, Cunxiang;Fan, Xiaobin
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1956-1964
    • /
    • 2018
  • Since the stator winding of High-Speed Permanent Magnet Generator (HSPMG) has few winding turns and low inductance value, it is more prone to be influenced by harmonic current. Moreover, the operation efficiency and the torque stability of HSPMG will be greatly influenced by harmonic current. Taking a 117 kW, 60 000 rpm HSPMG as an example, in order to analyze the effects of harmonic current on HSPMG in this paper, the 2-D finite element electromagnetic field model of the generator was established and the correctness of the model was verified by testing the generator prototype. Based on the model, the losses and torque of the generator under different frequency harmonic current were studied. The change rules of the losses and torque were found out. Based on the analysis of the influence of the harmonic phase angle on torque ripple, it is found that the torque ripple could be weakened through changing the harmonic phase angle. Through the analysis of eddy current density in rotor, the change mechanism of the rotor eddy current loss was revealed. These conclusions can contribute to reduce harmonic loss, prevent demagnetization fault and optimize torque ripple of HSPMG used in distributed power supply system.

On DC-Side Impedance Frequency Characteristics Analysis and DC Voltage Ripple Prediction under Unbalanced Conditions for MMC-HVDC System Based on Maximum Modulation Index

  • Liu, Yiqi;Chen, Qichao;Li, Ningning;Xie, Bing;Wang, Jianze;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.319-328
    • /
    • 2016
  • In this study, we first briefly introduce the effect of circulating current control on the modulation signal of a modular multilevel converter (MMC). The maximum modulation index is also theoretically derived. According to the optimal modulation index analysis and the model in the continuous domain, different DC-side output impedance equivalent models of MMC with/without compensating component are derived. The DC-side impedance of MMC inverter station can be regarded as a series xR + yL + zC branch in both cases. The compensating component of the maximum modulation index is also related to the DC equivalent impedance with circulating current control. The frequency characteristic of impedance for MMC, which is observed from its DC side, is analyzed. Finally, this study investigates the prediction of the DC voltage ripple transfer between two-terminal MMC high-voltage direct current systems under unbalanced conditions. The rationality and accuracy of the impedance model are verified through MATLAB/Simulink simulations and experimental results.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

도시가스 배관의 설비손상확률평가 (Frequence Analysis for City Gas Pipeline)

  • 박교식;이진한;조영도;박진희
    • 한국가스학회지
    • /
    • 제7권2호
    • /
    • pp.14-21
    • /
    • 2003
  • 도시가스 배관에서 위험을 유발할 수 있는 사건의 발생빈도를 구하기 위하여 주요 사고원인인 굴착공사, 외부부식, 지반침하 및 장치손상 등에 의한 사고발생빈도를 구하는 방법을 제시하였다. 굴착공사로 인한 손상은 FTA에 의해 기본사상(Basic event)을 도출하고, 부식에 의한 손상확률은 시간변화에 따른 부식결함의 잔존강도를 평가하는 평가식을 제시하였다. 지반침하로 인한 손상은 기준손상율을 구하고 여기에 손상모드인자 및 보정인자를 고려한 모델을 이용하여 구하였다. 장치원인에 의한 손상확률은 고유고장율과 특정고장율 자료를 모두 반영할 수 있는 방법을 제시하였으며 그 계산 예도 제시하였다.

  • PDF

한반도 인근 지진의 Brune 응력강하량(파라미터)추정에 대한 고찰 (Estimation of Brune's Stress Drops around the Korean Peninsula)

  • 연관희;박동희;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.70-77
    • /
    • 2006
  • Stress drops of Brune's single-corner ${\omega}^2$ source model were estimated for the earthquakes (2.0$M3.5{\sim}4.0$ and increase up to $M4.5{\sim}5.0$ above which the level of the stress drop could be assumed to be flat or decrease according to whether the rupture process accompanies buried fault or surface rupturing. The converted data of corner frequency and seismic moment were nicely fitted to the relation of $M_0{\propto}f^3$ but show systematically higher corner frequencies for $M_0>10^15$ Nm. This relationship enables systematic evaluation of a scaling relation between magnitude and stress drop. The inverted level of the stress drop is comparable to the recent studies conducted domestic and abroad. A result of lower stress drop estimated by Jun(1991) is supposed to be due to the use of low frequency spectra and existence of two-comer source model around the Korean Peninsula.

  • PDF