• Title/Summary/Keyword: Fault Frequency

Search Result 604, Processing Time 0.023 seconds

Design and Fabrication of a Wideband Ground Impedance Meter (광대역 접지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Han, Ju-Seop;Gil, Hyoung-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

Vibration Analysis of Ball Bearing Fault using HFRT (HFRT 기법을 이용한 결함 볼베어링의 진동분석)

  • Kim, Ye-Hyun;Kang, Byoung-Yong;kim, Dong-Il;Chang, Ho-Gyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.92-100
    • /
    • 1995
  • In this study, the bearing defects were modeled and the vibration of ball bearing faults was presented for the defective pattern. The vibration signal was measured for the single and multiple defected ball bearing at the various defect positions and rotation speed, and then the signal components using the HFRT(high frequency resonance technique) were analyzed by FFT. The experimental data analysis has shown that the frequencies generated in the single or multiple defected ball bearings appear with the characteristic defect frequency and harmonics of ball pass frequency peak. Signal processing by HFRT makes it possible not only to detect the presence of a defect but also to diagnose the defect part of the bearing.

  • PDF

Energy-efficient Custom Topology Generation for Link-failure-aware Network-on-chip in Voltage-frequency Island Regime

  • Li, Chang-Lin;Yoo, Jae-Chern;Han, Tae Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.832-841
    • /
    • 2016
  • The voltage-frequency island (VFI) design paradigm has strong potential for achieving high energy efficiency in communication centric manycore system-on-chip (SoC) design called network-on-chip (NoC). However, because of the diminished scaling of wire-dimension and supply voltage as well as threshold voltage in modern CMOS technology, the vulnerability to link failure in VFI NoC is becoming a crucial challenge. In this paper, we propose an energy-optimized topology generation technique for VFI NoC to cope with permanent link failures. Based on the energy consumption model, we exploit the on-chip communication traffic patterns and characteristics of link failures in the early design stage to accommodate diverse applications and architectures. Experimental results using a number of multimedia application benchmarks show the effectiveness of the proposed three-step custom topology generation method in terms of energy consumption and latency without any degradation in the fault coverage metric.

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

Development of Induction Motor Diagnosis Method by Variance Based Feature Selection and PCA-ELM (분산정보를 이용한 특징 선택과 PCA-ELM 기반의 유도전동기 고장진단 기법 개발)

  • Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.55-61
    • /
    • 2010
  • In this paper, we proposed selective extraction method of frequency information and PCA-ELM based diagnosis system for three-phase induction motors. As the first step for diagnosis procedure, DFT is performed to transform the acquired current signal into frequency domain. And then, frequency components are selected according to discriminate order calculated by variance As the next step, feature extraction is performed by principal component analysis (PCA). Finally, we used the classifier based on Extreme Learning Machine (ELM) with fast learning procedure. To show the effectiveness, the proposed diagnostic system has been intensively tested with the various data acquired under different electrical and mechanical faults with varying load.

Localization of Concentric Neutrals Corrosion on Live Underground Power Cable Based on Time-frequency Domain Reflectometry (시간-주파수 영역 반사파 계측법 기반 활선 상태 지중 전력 케이블의 중성선 결함 위치 추정 연구)

  • Lee, Chun Ku;Yoon, Tae Sung;Park, Jin Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.239-245
    • /
    • 2013
  • In this paper, we propose a time-frequency domain reflectometry (TFDR) based measurement method for localizing concentric neutrals corrosion on live underground power cable. It consists of two inductive couplers which can transmit the reference signal into live underground power cable and measure the reflected signals from the impedance discontinuities of concentric neutrals corrosion. In order to compensate the dispersion of the measured reflected signal via inductive coupler, an equalizer based on Wiener filtering is designed. To improve the localizing performance of concentric neutrals corrosion in the vicinity of the measurement point, the reference signal is removed from the measured reflected signals. The localization performance of the proposed method is verified by the concentric neutrals corrosion localization experiment.

Enhanced Dynamic Response of SRF-PLL System for High Dynamic Performance during Voltage Disturbance

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.369-374
    • /
    • 2011
  • Usually, a LPF (low pass filter) is used in the feedback loop of a SRF (synchronous reference frame) - PLL (phase locked loop) system because the measured grid voltage contains harmonic distortions and sensor noises. In this paper, it is shown that the cut-off frequency of the LPF should be designed to suppress the harmonic ripples contained in the measured voltage. Also, a new design method for the loop gain of the PI-type controller in the SRF-PLL is proposed with consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and the PI controller gain are designed in coordination according to the steady state and dynamic performance requirements. Furthermore, in the proposed method, the controller gain and the LPF cut-off frequency are changed from their normal value to a transient value when a voltage disturbance is detected. This paper shows the feasibility and usefulness of the proposed methods through the computer simulations and experimental results.

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

Assessing landslide susceptibility along the Halong - Vandon expressway in Quang Ninh province, Vietnam: A comprehensive approach integrating GIS and various methods

  • Nguyen-Vu Luat;Tuan-Nghia Do;Lan Chau Nguyen;Nguyen Trung Kien
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.135-147
    • /
    • 2024
  • A GIS-based landslide susceptibility mapping (LSM) was carried out using frequency ratio (FR), modified frequency ratio (M-FR), analytic hierarchy process (AHP), and modified analytic hierarchy process (M-AHP) methods to identify and delineate the potential failure zones along the Halong - Vandon expressway. The thematic layers of various landslide causative factors were generated for modeling in GIS, including geology, rainfall, distance to fault, distance to road, slope, aspect, landuse, density of landslide, vertical relief, and horizontal relief. In addition, a landslide inventory along the road network was prepared using data provided by the management department during the course of construction and operation from 2017 to 2019, when many landslides were documented. The validation results showed that the M-FR method had the highest AUC value (AUC = 0.971), which was followed by the FR method with AUC = 0.961. The AUC values were 0.939 and 0.892 for the M-AHP and AHP methods, respectively. The generated LSM obtained from M-FR method classified the study area into five susceptibility classes: very low (0), low (0-1), moderate (1-2), high (2-3), and very high (3-4) classes, which could be useful for various stakeholders like planners, engineers, designers, and local public for future construction and maintenance in the study area.

A Design of LLC Resonant Controller IC in 0.35 um 2P3M BCD Process (0.35 um 2P3M BCD 공정을 이용한 LLC 공진 제어 IC 설계)

  • Cho, Hoo-Hyun;Hong, Seong-Wha;Han, Dae-Hoon;Cheon, Jeong-In;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.71-79
    • /
    • 2010
  • This paper presents a design of a LLC resonant controller IC. LLC resonant controller IC controls the voltage of the 2nd side by adjusting frequency the input frequency of the external resonant circuit. The clock generator is integrated to provide the pulse to the resonant circuit and its frequency is controlled by the external resistor. Also, the frequency of the VCO is adjusted by the feedback voltage. The protection circuits such as UVLO(Under Voltage Lock Out), brown out, fault detector are implemented for the reliable and stable operation. The HVG, and LVG drivers can provide the high current and voltage to the IGBT. The designed LLC resonant controller IC is fabricated with the 0.35 um 2P3M BCD process. The overall die size is $1400um{\times}1450um$, and supply voltage is 5V, 15V.