• Title/Summary/Keyword: Fault Frequency

Search Result 605, Processing Time 0.025 seconds

Stator Current Processing-Based Technique for Bearing Damage Detection in Induction Motors

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1439-1444
    • /
    • 2005
  • Induction motors are the most commonly used electrical drives because they are rugged, mechanically simple, adaptable to widely different operating conditions, and simple to control. The most common faults in squirrel-cage induction motors are bearing, stator and rotor faults. Surveys conducted by the IEEE and EPRI show that the most common fault in induction motor is bearing failure (${\sim}$40% of failure). Thence, this paper addresses experimental results for diagnosing faults with different rolling element bearing damage via motor current spectral analysis. Rolling element bearings generally consist of two rings, an inner and outer, between which a set of balls or rollers rotate in raceways. We set the experimental test bed to detect the rolling-element bearing misalignment of 3 type induction motors with normal condition bearing system, shaft deflection system by external force and a hole drilled through the outer race of the shaft end bearing of the four pole test motor. This paper takes the initial step of investigating the efficacy of current monitoring for bearing fault detection by incipient bearing failure. The failure modes are reviewed and the characteristics of bearing frequency associated with the physical construction of the bearings are defined. The effects on the stator current spectrum are described and related frequencies are also determined. This is an important result in the formulation of a fault detection scheme that monitors the stator currents. We utilized the FFT, Wavelet analysis and averaging signal pattern by inner product tool to analyze stator current components. The test results clearly illustrate that the stator signature can be used to identify the presence of a bearing fault.

  • PDF

The time domain testing technique of RFIC based on specifications (설계사양기반 RF 집적회로의 시간영역 테스팅 기법)

  • Han Seok-Bung;Baek Han-Suk;Kim Kang-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.34-47
    • /
    • 2006
  • In this paper, a new testing technique for core components of wireless transceiver was proposed. That was, band fault models (including the information of specifications in the analogue and RF IC) and methods which can test specifications in the time domain easily by observing a variation of band fault models in the circuit output were proposed and developed. This technique had an advantage over testing technique in frequency domain because it didn't need expensive test equipments and could reduce the time required. Test technique proposed in this paper was adapted to the test of 5.25 GHz low noise amplifier and proved that this testing technique was efficient in RF IC including low noise amplifier.

A Study on the Developing Method of HIF Monitoring Data using Wavelet Coefficient (웨이브렛 계수를 이용한 고저항 지락고장 감시데이터 산출방법 연구)

  • Jung, Young-Beom;Jung, Yeon-Ha;Kim, Kil-Sin;Lee, Byung-Sung;Bae, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.155-163
    • /
    • 2013
  • As the increasing HIF(High Impedance Fault) with the arc cannot be easily detected for the low fault current magnitude compared to actual load in distribution line. However, the arcing current shows that the magnitude varies with time and the signal is asymmetric. In addition, discontinuous changes occur at starting point of arc. Considering these characteristics, wavelet transformation of actual current data shows difference between before and after the fault. Althogh raw data(detail coefficient) of wavelet transform may not be directly applied to HIF detection logic in a device, there are several developing methods of HIF monitoring data using the original wavelet coefficients. In this paper, a simple and effective developing methods of HIF monitoring data were analized by using the signal data through an actual HIF experiment to apply them to economic devices. The methods using the sumation of the wavelet coefficient squares in one cycle of the fundamental frequency as the energies of the wavelet coefficeits and the sumation of the absolute values were compared. Besides, the improved method which less occupies H/W resouces and can be applied to field detection devices was proposed. and also Verification of this HIF detection method through field test on distribution system in KEPCO power testing center was performed.

New On-Chip RF BIST(Built-In Self Test) Scheme and Circuit Design for Defect Detection of RF Front End (RF Front End의 결함 검출을 위한 새로운 온 칩 RF BIST 구조 및 회로 설계)

  • 류지열;노석호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.449-455
    • /
    • 2004
  • This paper presents a novel defect detection method for one chip RF front end with fault detection circuits using input matching measurement. We present a BIST circuit using 40.25{\mu}m$ CMOS technology. We monitor the input transient voltage of the RF front end to differentiate faulty and fault-free RF front end. Catastrophic as well as parametric variation fault models are used to simulate the faulty response of the RF front end. This technique has several advantages with respect to the standard approach based on current test stimulus and frequency domain measurement. Because DUT and fault detection circuits are implemented in the same chip, this test technique only requires use of digital voltmeter (RMS meter) and RF voltage source generator for simpleand inexpensive testing.

Building Bearing Fault Detection Dataset For Smart Manufacturing (스마트 제조를 위한 베어링 결함 예지 정비 데이터셋 구축)

  • Kim, Yun-Su;Bae, Seo-Han;Seok, Jong-Won
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.488-493
    • /
    • 2022
  • In manufacturing sites, bearing fault in eletrically driven motors cause the entire system to shut down. Stopping the operation of this environment causes huge losses in time and money. The reason of this bearing defects can be various factors such as wear due to continuous contact of rotating elements, excessive load addition, and operating environment. In this paper, a motor driving environment is created which is similar to the domestic manufacturing sites. In addition, based on the established environment, we propose a dataset for bearing fault detection by collecting changes in vibration characteristics that vary depending on normal and defective conditions. The sensor used to collect the vibration characteristics is Microphone G.R.A.S. 40PH-10. We used various machine learning models to build a prototype bearing fault detection system trained on the proposed dataset. As the result, based on the deep neural network model, it shows high accuracy performance of 92.3% in the time domain and 98.3% in the frequency domain.

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency (전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. The increase of voltage and current and thermal generation are extremely hard on the life of condenser. Current will be increased, provided that voltage and frequency of condenser increase also. The increase of voltage and frequency justly extends thermal generation. Both act on insulation stress and can afford to premature fault In this paper, we measured thermal distribution of condenser with infrared rays camera in case of variance of voltage and frequency. We were assured that the increase of voltage and frequency produces high heat and exceedingly shortens the life of condenser.

A Study on the Frequency Control for Cheju HVDC linked System (제주 HVDC 연게 시스템의 주파수 제어에 관한 연구)

  • Park, Jong-Kwang;Choi, Jong-Kee;Jin, Seong-Eun;Kim, Chan-Ki;Han, Byung-Sung;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.145-151
    • /
    • 2005
  • Cheju-Haenam HVDC link transmits electrical power up to 300[MW] Because of its size, HVDC system has a great potential for damping power system oscillations. This paper with the frequency control of the KEPCO HVDC system linking Haenam to Cheju island. Frequency control at Cheju island ensures that the island AC system frequency is maintained Performance are evaluated using a reduced Cheju network and a detailed model of the fm system modelled in the PST software. Transient oscillations for the 3 phase fault carried out with HVDC frequency control are well damped as the control parameters have been adjusted.

Behaviour of asymmetric building with double variable frequency pendulum isolator

  • Soni, D.P.;Mistry, B.B.;Panchal, V.R.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.1
    • /
    • pp.61-84
    • /
    • 2010
  • Presented in this paper is the behaviour of asymmetric building isolated by the double variable frequency pendulum isolator (DVFPI). The DVFPI is an adoption of single variable frequency pendulum isolator (VFPI). The geometry and coefficient of friction of top and bottom sliding surfaces can be unequal. The governing equations of motion of the building-isolation system are derived and solved in incremental form. The analysis duly considers the interaction of frictional forces in the two principal directions developed at each sliding surface of the DVFPI. In order to investigate the behaviour of the base isolation using the DVFPI, the coupled lateral-torsional response is obtained under different parametric variations for a set of six far-fault earthquake ground motions and criterion to optimize its performance is proposed. Further, influences of the initial time period, coefficient of friction and frequency variation factors at the two sliding surfaces are investigated. The numerical results of the extensive parametric study help in understanding the torsional behaviour of the structure isolated with the double sliding surfaces as in the DVFPI. It is found that the performance of the DVFPI can be optimized by designing the top sliding surface initially softer and smoother relative to the bottom one.

Development of Coupler for Live Cable Fault Detection Based on Reflectometry (반사파 계측법 기반의 활선 케이블 고장 검출을 위한 커플러의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.401-406
    • /
    • 2016
  • When measuring live cable faults and their location based on reflectometry, a coupler is placed between the cable and the test system. This coupler prevents damage to the test circuits by indirectly measuring the live voltage of the cable using reflectometry. It also provides a coupling path that allows the transmission and receive signal to pass into the cable. In this study, we design and construct a contact coupler to locate faults in both dead and live cables using reflectometry. The proposed coupler is of the inductive coupling type and is constructed after the calculation of the signal transmission loss by simulation. The performance of the developed coupler is tested by measuring the transmission loss and frequency flatness. The results showed that the transmission signal loss is less than -1.98dB in the frequency bandwidth above 1 Mhz. The reflectometry system was designed based on sequence time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) in order to apply it to the detection of faults and their location in live cables and tests on live cables were performed. The test results showed that the proposed coupler can be used in a reflectometry system for live cable fault detection.