A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lee, Dong-Jun;Kim, Chul-Hwan;Kim, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

Analysis of Characteristic Frequency along Fault Distance on a Transmission Line (송전 선로의 사고 거리에 따른 특성 주파수 해석)

  • 남순열;홍정기;강상희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.

Estimation of Fault Location on a Transmission Line via Time-Frequency Domain Reflectometry (시간-주파수 반사파 계측 방법을 이용한 전송선로의 결함 위치 추정)

  • Choe TokSon;Kwak Ki-Seok;Yoon Tae Sung;Park Jin Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.521-530
    • /
    • 2005
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry(TFDR), isproposed to detect and estimate a fault in a transmission line. Traditional reflectometry methodologies have been achieved either in the time domain or in the frequency domain only. However, the TFDR can jump over the performance limits of the traditional reflectometry methodologies because the acquired signal is analyzed in time and frequency domain simultaneously. In the TFDR, the new reference signal and the novel TFDR algorithm are proposed for analyzing the acquired signal in the time-frequency domain. Because the reference signal of Gaussian envelop chirp signal is localized in the time and frequency domain simultaneously, it is suitable to the analysis in the time-frequency domain. In the proposed TFDR algorithm, the time-frequency distribution function and the normalized time-frequency cross correlation function are used to detect and estimate a fault in a transmission line. That algorithm is verified for real-world coaxial cables which are typical transmission line with different types of faults by the TFDR system composed of real instruments. The performance of the TFDR methodology is compared with that o( the commercial time domain reflectomeoy(TDR) experiments, so that concludes the TFDR methodology can detect and estimate the fault with smaller error than TDR methodology.

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated high frequency signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lim, Byung-Ho;Kim, Chul-Hwan;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1376-1378
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range In this respect, this paper describes the basis of a Protection technique for transmission lines which utilises high-frequency components. Fault-generated signals caused by post-fault and the signal derived from stack tuner is connected to the coupling capacitor of CVT. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the Protected zone, and to discriminate the fault type on transmission line.

  • PDF

Estimation of Fault Location on a Power Line using the Time-Frequency Domain Reflectometry (절연전선 결함 위치 추정에 대한 시간-주파수 영역 반사파 계측법의 적용)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.268-275
    • /
    • 2008
  • In this paper, we introduce a new method for detecting and estimating faults on a power line using the time-frequency domain reflectometry system. The system rests upon time-frequency signal analysis and uses a chirp signal which is multiplied by Gaussian envelope. The chirp signal is used as a reference signal, and we can get the reflected signal from a fault on a wire. To detect and estimate faults, we analyze the reflected signal by Wigner time-frequency distribution function and normalized time-frequency cross correlation function. In this paper we design an optimal reference signal for power line and implement a system for estimating fault distance on a power line with the TFDR implemented by PXI equipments. This approach is verified by some experiments with HIV 2.25mm power lines.

Frequency analysis based fault detection and isolation of induction motors (주파수 해석을 이용한 유도전동기의 고장 검출 및 분류)

  • 신필재;이인수;전기준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.702-705
    • /
    • 1996
  • Recently, induction motors are used more widely because of their low cost and simple structure. Therefore, the importance of fault detection and isolation of induction motors significantly increases. In most case the line current is used for fault detection and isolation. But in case that an induction motor has an inverter for control, it distorts the information of faulty state included in the line current. This paper proposes a new method for fault detection and isolation of induction motors that is speed controlled by the inverter using frequency analysis of the reference current instead of the line current for fault detection and isolation.

  • PDF

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Detection and Estimation of a Faults on Coaxial Cable with TFDR Algorithm (Time Frequency Domain Reflectometry 기법을 이용한 Coaxial Cable에서의 결함 감지 및 추정)

  • Song, Eun-Seok;Shin, Yong-June;Choe, Tok-Son;Yook, Jong-Gwan;Park, Jin-Bae;Powers, Edward J.
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.1
    • /
    • pp.38-50
    • /
    • 2003
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry (TFDR), is proposed to detect and locate fault in wiring. Traditional reflectometry methods have been achieved in either the time domain or frequency domain only. However, time-frequency domain reflectometry utilizes time and frequency information of a transient signal to detect and locate the fault. The time-frequency domain reflectometry approach described in this paper is characterized by time-frequency reference signal design and post-processing of the reference and reflected signals to detect and locate the fault. Design of the reference signal in time-frequency domain reflectometry is based on the determination of the frequency bandwidth of the physical properties of cable under test. The detection and estimation of the fault on the time-frequency domain reflectometry relies on the time-frequency domain reflectometry is compared with commercial time domain reflectomtery (TDR) instrument. In these experiments provided in this paper, TFDR locates the fault with smaller error than TDR. Knowledge of time and frequency localized information for the reference and reflected signal gained via time-frequency analysis, allows one to detect the fault and estimate the location accurately.

  • PDF

Fault Diagnosis Based on MCSA for Gearbox of BLDC Motor (MCSA 기반의 BLDC 모터 기어박스의 고장 진단)

  • Shin, Sa-Chul;Kim, Jun-Young;Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2069-2070
    • /
    • 2011
  • In this paper, the fault diagnosis for a gearbox of BLDC motor. The stator of BLDC motor consists of coil winding so it is easy to cool down and it also has a high reliability. In addition, it doesn't have a brush so it is less trouble and good in maintenance. Coupling with the motor which is the power sources, the gear has a high power transfer efficiency and various rotation speed. The gear gets a high driving force through deceleration. Thus it has been widely used. The gearbox fault detection area has not attracted much attention from electrical engineering community. A few papers describe gearbox fault based on vibration. Gearbox fault is diagnosed through FFT analysis of current and voltage. Fault characteristic frequency side band detected by calculating fault frequency. A threshold value is suggested by comparing normal peak value with fault peak value using detected fault characteristic frequency side band. Experimental results demonstrate that motor current and voltage signal analysis are viable tools in detecting these gear faults. Lower side band(LSB) is bigger than upper side band(USB) in current FFT. LSB and USB are similar in voltage FFT. Finally, fault diagnosis system that can easily detect flaws is developted for gearbox of BLDC motor.

  • PDF

Image Processing Based Time-Frequency Domain Reflectometry for Estimating the Fault Location Close to the Applied Signal Point (케이블 내 근접 결함 추정을 위한 영상 처리 기반의 시간 주파수 영역 반사파 계측법)

  • Jeong, Jong Min;Lee, Chun Ku;Yoon, Tae Sung;Park, Jin Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1683-1689
    • /
    • 2014
  • In this paper, we propose an image processing based time-frequency domain reflectometry(TFDR) in order to estimate the fault location of a cable. The Wigner-Ville distribution is used for analysis in both the time domain and the frequency domain when the conventional TFDR estimates the fault location in a cable. However, the Winger-Ville distribution is a bi-linear function, and hence the cross-term is occurred. The conventional TFDR cannot estimate the accurate fault location due to the cross-term in case the fault location is close to the position where the reference signal is applied to the cable. The proposed method can reduce the cross-term effectively using binarization and morphological image processing, and can estimate the fault location more accurately using the template matching based cross correlation compared to the conventional TFDR. To prove the performance of the proposed method, the actual experiments are carried out in some cases.