• 제목/요약/키워드: Fault Code

검색결과 124건 처리시간 0.021초

A Simple Fault Correction Method for Rotor Position Detection of Brushless DC Motor using a Latch Type Hall Effect Sensor

  • Baik In-Cheol;Joo Hyeong-Gil
    • Journal of Power Electronics
    • /
    • 제5권1호
    • /
    • pp.62-66
    • /
    • 2005
  • A simple fault correction method for rotor position detection of a brushless DC(BLDC) motor with trapezoidal back EMF(electromotive force) using a Hall effect latch unit is presented. The reason why the Hall effect latch unit does not operate properly during the startup of a BLDC motor is thoroughly explained. To solve this problem, a simple code change method and its hardware implementation issues are proposed and discussed.

근거리지진의 특성과 동적응답스펙트럼에 관한 연구 (A Study on Characteristics and Dynamic Response Spectrum of Near Fault Ground Motions)

  • 방명석;한성호
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.143-151
    • /
    • 2005
  • In this study, it is demonstrated that how the effect of the Near Fault Ground Motion affects the response of the structure. Considering the general characteristic of Near Fault Ground Motion the characteristics of Near Fault Ground Motions is analysed by elastic response spectrums, and the inelastic response spectrum is evaluated with the ductility and the yield strength to consider the inelastic behavior which couldn't be simulated through the elastic response spectrum. The result of this study shows that the effect of Near Fault Ground Motion should be considered in the long period range of long span structures but the domestic seismic design code was developed based on Far Fault Ground Motions, so the effects of Near Fault Ground Motions, which is very serious especially in large structures with a long period, are not considered. Therefore, the effect of the Near Fault Ground Motion has to be examined especially in the seismic performance evaluation of long period structure.

IEEE 1547a 전압기준에 대한 Fault Ride-through 요구사항에 관한 고찰. (A study on requirement of fault ride- through about voltage on IEEE 1547)

  • 이윤민;이일용;윤선재;박아련;김희중;조주현;김영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.81-82
    • /
    • 2016
  • 본 논문에서는 미국의 분산전원 연계용 PCS에 적용되는 Grid Code인 IEEE1547 Amendment의 fault ride-through에 대해 기술한다. IEEE 1547은 2014년 Amendment가 발행되었으며, 전압/주파수에 대한 사고판단 능력이 업데이트 되어 fault ride-through의 범위가 변경되었다. 개정된 IEEE1547a의 기준을 분석하고, 이를 적용한 fault ride-through 기능을 PSIM 시뮬레이션을 통하여 검증하였다.

  • PDF

수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B (Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B)

  • 윤정석
    • 터널과지하공간
    • /
    • 제30권4호
    • /
    • pp.320-334
    • /
    • 2020
  • 본 수치해석연구에서는 국제공동연구프로젝트 DECOVALEX2019의 Task B의 일환으로 PFC3D를 기반으로한 수리역학연계모델을 개발하여 스위스 Mont Terri 지하연구시설에서 수행된 단층의 유체주입으로 인한 슬립시험을 모사하였다. 이를통해, 개발한 PFC3D 수리역학연계모델이 가진 한계점과 향후 보완할 점을 검토하고자 하였다. PFC3D를 기반으로한 3차원 입자결합모델 내 공극-유동통로모델을 생성하였으며 이를 사용하여 Mont Terri Step 2 단층내 유체주입실험을 모사하였다. 모델링결과 단층대를 따라 주입유체의 유동에 의한 단층대의 변형을 확인하였지만, 관측정에서의 시간에 따른 수압변화는 현장측정치와 부분적으로 일치하는 경향을 확인하였다. 현장측정 관측수압은 초기 유체주입 압력증가에 거의 변화를 보이지 않고 주입수압이 최대치에 도달할때쯤 급격한 증가를 보이는반면, 모델링에서는 주입압력이 증가함에 따라 관측수압도 부드럽게 증가하는 경향을 보였다. 이러한 부분적으로 일치하는 결과의 원인으로는 Mont Terri 현장의 단층을 모사하는 방법에 기인하는 것으로 판단하다. PFC3D에서는 단층을 손상대와 코어균열의 조합으로 모사하였고 단층대의 두께가 약 2 m로 주입유체가 단층대를 통해 유동하도록 모사하였기에 현장에서의 주입유체의 단층내 유동보다 그 유동범위가 크게 모사되었다고 판단한다. 또한, 현장단층에서와 같이 단층내부에 존재하는 충진물질로 인해 단층내 수리유동이 제한되어 국부적으로 과잉공급수압이 형성될 수 있는 기재를 모사하지 못한 점 또한 모델링 결과와 현장측정결과가 부분적으로 일치하는 원인일 수 있다. 단층변형의 경우는 모델링결과와 현장측정결과 유사한 수준으로 일치하는 결과를 확인하였다. 수치모델을 변형하여 단층대의 두께를 감소시키고 단층내 충진 물질의 비균질적인분포를 모사할 수 있는 방법론에 대한 후속 연구를 통해 PFC3D 수리역학연계모델의 유체주입으로 인한 단층활성화 연구로의 적용성을 향상시키는 것을 제안하고 한다.

단층대를 통과하는 터널의 안정성확보에 관한 연구 (A Study of Stability Evaluation for Tunnel at the Fault Zone Crossing)

  • 박인준;최정환;김수일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.105-112
    • /
    • 2001
  • The purpose of this study is to assess the stability of tunnel for a high speed railway crossing the fault zone. The area where the tunnel crossed the fault zone can be unstable during construction and operation. Geotechnical investigations have been conducted to determine an optimum excavation method by obtaining the material properties around the fault zone and to check the stability of the tunnel. For the numerical analysis, the FLAC, numerical analysis code based on finite difference method, was utilized to analyze the behavior of the fault at three points having typical ground conditions. Based on the results of numerical analysis, the combinations of compaction grouting and LW grouting were determined as suitable methods for pre-excavation Improvement of the ground surrounding the tunnel opening. In conclusion, the stability of the tunnel construction for the high speed railway within the fault zone may be obtained by adopting the optimum excavation method and the reinforcement method. The numerical analysis based on FLAC program contains errors caused by assumptions used in numerical analysis, therefore constant monitoring with respect to the change of ground condition and groundwater is highly recommended to minimize the numerical error and the possibility of damage to tunnel.

  • PDF

소프트웨어 신뢰성 예측을 위한 객체지향 척도 분석 (Analysis of Object-Oriented Metrics to Predict Software Reliability)

  • 이양규
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권1호
    • /
    • pp.48-55
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the object-oriented metrics which have strong impact on the reliability and fault-proneness of software products. The reliability and fault-proneness of software product is closely related to the design properties of class diagrams such as coupling between objects and depth of inheritance tree. Methods: This study has empirically validated the object-oriented metrics to determine which metrics are the best to predict fault-proneness. We have tested the metrics using logistic regressions and artificial neural networks. The results are then compared and validated by ROC curves. Results: The artificial neural network models show better results in sensitivity, specificity and correctness than logistic regression models. Among object-oriented metrics, several metrics can estimate the fault-proneness better. The metrics are CBO (coupling between objects), DIT (depth of inheritance), LCOM (lack of cohesive methods), RFC (response for class). In addition to the object-oriented metrics, LOC (lines of code) metric has also proven to be a good factor for determining fault-proneness of software products. Conclusion: In order to develop fault-free and reliable software products on time and within budget, assuring quality of initial phases of software development processes is crucial. Since object-oriented metrics can be measured in the early phases, it is important to make sure the key metrics of software design as good as possible.

Structural damage distribution induced by Wenchuan Earthquake on 12th May, 2008

  • Jia, Junfeng;Song, Nianhua;Xu, Zigang;He, Zizhao;Bai, Yulei
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.93-109
    • /
    • 2015
  • Based on the reconnaissance of buildings in Dujiangyan City during 2008 Wenchuan earthquake, China, structural damage characteristics and the spatial distribution of structural damage are investigated, and the possible reasons for the extraordinary features are discussed with consideration of the influence of urban historical evolution and spatial variation of earthquake motions. Firstly, the urban plan and typical characteristics of structural seismic damage are briefly presented and summarized. Spatial distribution of structural damage is then comparatively analyzed by classifying all surveyed buildings in accordance with different construction age, considering the influence of seismic design code on urban buildings. Finally, the influences of evolution of seismic design code, topographic condition, local site and distance from fault rupture on spatial distribution of structural damage are comprehensively discussed. It is concluded that spatial variation of earthquake motions, resulting from topography, local site effect and fault rupture, are very important factor leading to the extraordinary spatial distribution of building damage except the evolution of seismic design codes. It is necessary that the spatial distribution of earthquake motions should be considered in seismic design of structures located in complicated topography area and near active faults.

Necessity and adequacy of near-source factors for seismically isolated buildings

  • Saifullah, Muhammad Khalid;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.91-108
    • /
    • 2017
  • Superstructures and isolation systems of seismically isolated buildings located close to active faults may observe increased seismic demands resulting from long-period and high-amplitude velocity and displacement pulses existent in near-fault ground motions as their fundamental periods may be close to or coincident with these near-fault pulse periods. In order to take these effects into account, the 1997 Uniform Building Code (UBC97) has specified near-source factors that scale up the design spectrum depending on the closest distance to the fault, the soil type at the site, and the properties of the seismic source. Although UBC97 has been superseded by the 2015 International Building Code in the U.S.A., UBC97 near-source factors are still frequently referred in the design of seismically isolated buildings around the world. Therefore it is deemed necessary and thus set as the aim of this study to assess the necessity and the adequacy of near-source factors for seismically isolated buildings. Benchmark buildings of different heights with isolation systems of different properties are used in comparing seismic responses obtained via time history analyses using a large number of historical earthquakes with those obtained from spectral analyses using the amplified spectrums established through UBC97 near-source factors. Results show that near-source factors are necessary but inadequate for superstructure responses and somewhat unconservative for base displacement response.

Nonlinear static and dynamic behavior of reinforced concrete steel-braced frames

  • Eskandari, Reyhaneh;Vafaei, Davoud;Vafaei, Javid;Shemshadian, Mohammad Ebrahim
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.191-200
    • /
    • 2017
  • In this paper, the seismic performance of reinforced concrete braced frames (RC-BF) under far- and near-fault motions was investigated. Four-, eight-, 12- and 16-story RC-BFs were designed on the basis of a code-design method for a high risk seismic zone. Nonlinear static and dynamic analyses of the frames have been performed using OpenSees software. To consider diverse characteristics of near-fault motions, records with forward-directivity and fling-step effects were employed. From the results obtained in the analytical study it is concluded that the used design method was reasonable and the mean maximum drift of the frames under all ground motion sets were in acceptable range. For intermediate- and high-rise buildings the near-fault motions imposed higher demands than far-faults.

결함 어골도 분석에 의한 모바일 결제 시스템의 보안성 개선에 관한 연구 (A Study on the Security Improvement for Mobile Payment Systems by the Fault Fishbone Analysis)

  • 서진호;박만곤
    • 한국멀티미디어학회논문지
    • /
    • 제21권1호
    • /
    • pp.26-33
    • /
    • 2018
  • As financial transactions using mobile devices have been activated, mobile payment services have appeared and many changes have been made to the existing financial service methods. Due to the simplified payment method of mobile payment service, security threats such as personal information leakage, phishing damage, and malicious code are increasing. Research that can solve this is needed. In this paper, we discuss the features and security factors of mobile payment system. In order to improve the security of mobile payment system, we propose a fault analysis method based on frequency of occurrence using Fault Fishbone Analysis(FFA) technique.