• Title/Summary/Keyword: Fatigue(피로)

Search Result 5,260, Processing Time 0.034 seconds

Frontal Face Video Analysis for Detecting Fatigue States

  • Cha, Simyeong;Ha, Jongwoo;Yoon, Soungwoong;Ahn, Chang-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.6
    • /
    • pp.43-52
    • /
    • 2022
  • We can sense somebody's feeling fatigue, which means that fatigue can be detected through sensing human biometric signals. Numerous researches for assessing fatigue are mostly focused on diagnosing the edge of disease-level fatigue. In this study, we adapt quantitative analysis approaches for estimating qualitative data, and propose video analysis models for measuring fatigue state. Proposed three deep-learning based classification models selectively include stages of video analysis: object detection, feature extraction and time-series frame analysis algorithms to evaluate each stage's effect toward dividing the state of fatigue. Using frontal face videos collected from various fatigue situations, our CNN model shows 0.67 accuracy, which means that we empirically show the video analysis models can meaningfully detect fatigue state. Also we suggest the way of model adaptation when training and validating video data for classifying fatigue.

Fatigue Strength of Dental Implant in Simulated Body Environments and Suggestion for Enhancing Fatigue Life (생체유사환경 하의 치과용 임플란트의 피로강도 평가 및 수명 향상법)

  • Kim, Min Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2014
  • Fatigue tests were performed in various simulated body environments reflecting various factors (such as body fluids, artificial saliva) relevant within a living body. First, the fatigue limit under a simulated body environment (artificial saliva) was evaluated and the governing factors of implant fatigue strength were looked into by observing the fracture mode. The fatigue life of an implant decreased in the artificial saliva environment compared with that in the ringer environment. Furthermore, in the artificial saliva environment, the implant fracture mode was fatigue failure of fixture as opposed to the abutment screw mode in the ringer environment. In the fatigue test, corrosion products were observed on the implant in the simulated body environment. A larger amount of corrosion products were generated on the artificial saliva specimen than on the ringer specimen. It is thought that the stronger corrosion activity on the artificial saliva specimen as compared with that on the ringer specimen led to an overall decrease of fatigue life of the former specimen. In the case of the implant with a nitrided abutment screw eliminated hardened layer (TixN), a several times increase in fatigue life is achieved in comparison with tungsten carbide-coated implants.

Ultrasonic evaluation of small surface fatigue cracks initiating in residual stress zone (잔류응력 영역에서 발생한 작은 피로균열의 초음파 평가)

  • Kang Kae-Myung;Kim Jin-Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.55-62
    • /
    • 2000
  • A surface acoustic wave method for the evaluation of small fatigue crack initiated from a pit-type surface flaw is presented. In-situ ultrasonic experiments are performed for aluminum 2024-T3 alloy samples under the fatigue test. During the fatigue test, the surface acoustic wave reflection signal from the pit and crack is measured under different hold-stress levels. From the measured and predicted surface wave reflections the depths of fully and partially open cracks are determined and results are verified by comparing with SEM fractography The crack opening behavior of the fatigue crack is evaluated from the predicted effective crack depths. The method developed in this study can be applied to monitor and characterize crack initiation and propagation from pit-type surface flaws in the early stage of fatigue life.

  • PDF

A Theoretical and Experimental Investigation on the Fatigue Strength and Fatigue Reliability Analysis of Concrete (콘크리트의 피로강도 및 피로신뢰성해석에 관한 이론 및 실험연구)

  • Oh, Byung Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.113-119
    • /
    • 1985
  • The fatigue strength and reliability of concrete subjected to ftexural loading is investigate. The concrete beam specimens are prepared and tested in four-point flexural loading in which the bottom fiber stress varies from zero to a predetermined maximum stress. The S-N curves are generated from these test results and an equation is obtained by regression analysis to predict the flexural fatigue strength of concrete. A method is presented to perform the probabilistic analysis on the flexural fatigue of concrete. It is shown that the Weibull distribution has physically more convincing features and may be appropriate to describe the fatigue behavior of concrete.

  • PDF

Analysis on fatigue life distribution of composite materials (복합재료 피로 수명 분포에 관한 고찰)

  • 황운봉;한경섭
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.790-805
    • /
    • 1988
  • Static strength and fatigue life scattering of glass fiber reinforced epoxy composite materials has been studied. Normal, lognormal, two-parameter and three-parameter Weibull distribution functions are used for strength and one-stress fatigue life distribution. The value of mean fatigue life is analysed using mean fatigue life, mean log fatigue life and expected value of 2 and 3-parameter Weibull distribution functions. Modification on non-statistical cumulative damage models is made in order to interpret the result of two-stress level fatigue life scattering. The comparison results show that 3-parameter Weibull distribution has better predictions in static strength and one-stress level fatigue life distributions. However, no advantage of 3-parameter Weibll distribution is found over 2-parameter Weibull distribution in two-stress level fatigue life predictions. It is found that two-stress level fatigue life prediction by the expanded equal rank assumption is close to the experimental data.

Effect of Cd addition on the Fatigue Properties of Al-Cu-Mn cast alloy (Al-Cu-Mn 주조합금의 피로성질에 미치는 Cd 첨가의 영향)

  • Kim, Gyeong-Hyeon;Lee, Byeong-Hun;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.11 no.4
    • /
    • pp.300-304
    • /
    • 2001
  • Effect of Cd addition on the fatigue properties of Al-Cu-Mn cast alloy was investigated by low and high cycle fatigue tests. With increasing Cd content, fatigue life and tensile strength were increased. It was found that the fatigue strength was 115MPa and the fatigue ratio was 0.31. Metallographic observation revealed that the fatigue crack initiated at the surface and propagated along the grain boundary. This propagation path was attributed to the presence of PFZ along the grain boundary. The tensile strength increased from 330MPa in the Cd-free Al-Cu- Mn cast alloy to 401MPa in the 0.15%Cd-containing alloy.

  • PDF

Comparison and Evaluation of Low-Cycle Fatigue Life Prediction Methods Using Cu-Cr Alloy Developed for Rocket Engines (로켓엔진용 구리크롬 합금의 저주기 피로수명 예측방법 비교 및 평가)

  • Jongchan Park;Jae-Hoon Kim;Keum-Oh Lee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.5
    • /
    • pp.1-10
    • /
    • 2022
  • For Cu-Cr alloy developed for rocket engines, estimated fatigue lives were calculated using various fatigue life prediction methods and compared with fatigue life acquired from low-cycle fatigue tests. The utilized methods for fatigue life prediction are as follows: Coffin-Manson relation, plastic/total strain energy density relations, Smith-Watson-Topper relation, Tomkins relation, and Jahed-Varvani relation. As results of estimation of fatigue lives, it satisfied within scatter band two compared to the test fatigue lives in all methods. The quantitative calculation of the deviation of predicted fatigue lives gives that the total strain energy density relation presents the best result.

Prediction of Fatigue Crack Propagation Life under Constant Amplitude and Overloading Condition (일정진폭 및 과대하중 하에서의 피로 균열 성장 수명 예측)

  • 이억섭;김승권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.113-119
    • /
    • 1998
  • Ship structures and aircraft structures are consisted of thin sheet alloy, so it is very important to understand the characteristics of fatigue crack propagation of that material and to establish the data base. The data for fatigue crack propagation behavior scatter very much even under identical experimental conditions with constant loading. The behavior of fatigue crack propagation under regular and irregular cyclic loadings is known to be highly affected by complicated factors such as plastic zone developed at the vicinity of crack tip and reduction of cross sectional area. In this paper, the controlled stress amplitude and overload fatigue crack propagation tests have been conducted to investigate the effect of varying factors such as plastic zone size near the crack tip and area reduction factor (AF) on the fatigue crack propagation behavior A better simulation of fatigue crack propagation behavior is found to be obtainable by using Wheeler and Willenborg models with AF effect.

  • PDF

The Effects of Microcurrent Stimulation on Erector Spinae Fatigue Index (미세전류 자극이 척주세움근의 피로지수에 미치는 영향)

  • Kang, Da-Haeng
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.545-551
    • /
    • 2013
  • This study aimed to compare the effects of microcurrent stimulation and rest on the fatigue index by applying both to subjects who had accumulated fatigue after performing short-duration physical activity. The experiment was performed at S University from December 2012 to February 2013, on 22 healthy men in their 20s, who were right-handed, and without peripheral or musculoskeletal diseases. All subjects lifted a 10-kg box lift and lower 100 times in 15 minutes. Immediately after that, muscle fatigue index (Median Frequency: MF) and blood fatigue index (Creatine Kinase Lactate: CK, Lactate Dehydrogenase: LDH) were measured by using surface electromyography. The subjects were divided into two groups, and microcurrent stimulation and rest were mediated to the experimental and control groups, respectively, for 20 minutes. After intervention, muscle fatigue index and blood fatigue index were measured and the changes in the accumulated fatigue index were compared. Both groups manifested significantly decreased cumulative fatigue after applying the mediation compared to the pre-intervention level (p < .05), the only exception being the fatigue index of the left erector spinae in the rest group. Compared to the rest group, the microcurrent stimulation group showed a significant decrease in muscle fatigue index (p < .05) but no significant differences were found in the blood fatigue index. Given the results of this study, microcurrent stimulation is considered to be helpful in muscle fatigue recovery for workers who have to perform repetitive movements lifting weights, and additional studies on the correlations of the fatigue recovery with respect to the long-term follow-up of fatigue index and mediation time are necessary.

Factors Related to Fatigue in Cancer Patients Receiving Chemotherapy (항암 화학요법 환자의 피로 관련 요인)

  • Jung, Eun-Ja;Jung, Young;Park, Mi-Young
    • Journal of Hospice and Palliative Care
    • /
    • v.7 no.2
    • /
    • pp.179-188
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the degree of fatigue and its related factors in cancer patients during chemotherapy. Methods: The subjects of this study consisted of 90 patients over 20 years old who were receiving chemotherapy at the injection room of the o.p.d. and ward admission care unit in a University hospital located in Gwang-ju city and data were collected from August 8th to October 2nd, 2002. Collected data were analysed using SPSS v 10.0. to obtain summary statistics for the descriptive analysis, t-test, ANOVA, pearson correlation, and multiple regression. Results: 1. Fatigue of the subjects was significantly correlated with physical distress score. and 6 items of subscale those were nausea, vomiting, anorexia, pain, and immobility, showed statistically significant correlation. 2. Fatigue of the subjects showed statistically significant differences according to a nap satisfaction. Fatigue of the subjects was significantly correlated with mood state, Also, all 5 items of subscale, which are those were anxiety, confusion, depression, energy, and anger showed statistically significant correlations. 3. Fatigue of the subjects showed statistically significant differences according to metastasis, chemotherapy cycle, post operation existence, post radiation therapy existence. There were significant negative correlation between fatigue and hematocrit and fatigue and weight change. There was no significant correlation between fatigue and spiritual well-being state. With the result to multiple regression, Immobility, Anorexia, Anger explained fatigue by, pain, and immobility showed statistically significant correlation.

  • PDF