• 제목/요약/키워드: Fast peak detector

검색결과 15건 처리시간 0.023초

A 0.12GHz-1.4GHz DLL-based Clock Generator with a Multiplied 4-phase Clock Using a 0.18um CMOS Process

  • Chi, Hyung-Joon;Lee, Jae-Seung;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.264-269
    • /
    • 2006
  • A $0.12GHz{\sim}1.4GHz$ DLL-based clock generator with the capability of multiplied four phase clock generation was designed using a 0.18um CMOS process. An adaptive bandwidth DLL with a regulated supply delay line was used for a multiphase clock generation and a low jitter. An extra phase detector (PD) in a reference DLL solves the problem of the initial VCDL delay and achieves a fast lock time. Twice multiplied four phase clocks were generated at the outputs of four edge combiners, where the timing alignment was achieved using a coarse lock signal and the 10 multiphase clocks with T/8 time difference. Those four clocks were combined one more time using a static XOR circuit. Therefore the four times multiplication was achieved. With a 1.8V supply, the rms jitter of 2.1ps and the peak-to-peak jitter of 14.4ps were measured at 1.25GHz output. The operating range is $0.12GHz{\sim}1.4GHz$. It consumes 57mW and occupies 450*325um2 of die area.

Fast Determination of Multiple-Reaction Intermediates for Long-Chain Dicarboxylic Acid Biotransformation by Gas Chromatography-Flame Ionization Detector

  • Cho, Yong-Han;Lee, Hye-Jin;Lee, Jung-Eun;Kim, Soo-Jung;Park, Kyungmoon;Lee, Do Yup;Park, Yong-Cheol
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권5호
    • /
    • pp.704-708
    • /
    • 2015
  • For the analysis of multiple-reaction intermediates for long-chain dicarboxylic acid biotransformation, simple and reproducible methods of extraction and derivatization were developed on the basis of gas chromatography with flame ionization detector (GC-FID) instead of mass spectrometry. In the derivatization step, change of the ratio of pyridine to MSTFA from 1:3 to 9:1 resulted in higher peak intensity (p = 0.021) and reproducibility (0.6%CV) when analyzing 32 g/l ricinoleic acid (RA). Extraction of RA and ω-hydroxyundec-9-enoic acid with water containing 100 mM Tween 80 showed 90.4-99.9% relative extraction efficiency and 2-7%CV compared with those with hydrophobic ethyl acetate. In conclusion, reduction of the pyridine content and change of the extraction solvent to water with Tween 80 provided compatible derivatization and extraction methods to GC-FID-based analysis of longchain carboxylic acids.

초음파 탐상을 위한 고속 아날로그 입력 카드의 설계 (Design of High Speed Analog Input Card for Ultrasonic Testing)

  • 이병수;이동원;박두석
    • 한국컴퓨터정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.62-68
    • /
    • 2000
  • A/D Board는 Data Acquisition 시스템에서 가장 중요한 하드웨어 기술로써, 컴퓨터를 이용하는 계측기기에 필수적으로 사용되는 장치이다. 특히, 초음파 탐상 장치의 A/D Board는 수 MHz대의 초음파를 디지털로 변환하기 위해 고속의 A/D 변환기가 필요하고, PC 메모리로 직접 전송할 수 있는 DMA 방식의 회로 설계가 요구된다. 본 연구는 측정하려는 대상으로부터 반사된 초음파 신호를 고속의 A/D 변환기에 의해 디지털화 한 후, 데이터의 Peak값을 추출하여 ISA Bus를 통해서 PC로 전송 지켜주는 카드를 설계하였다. 초음파 탐상에 사용되는 주파수가 보통 10MHz 이상이므로 이 신호를 안정적으로 획득하기 위해서는 샘플링 속도가 초음파 주파수 보다 굇배 이상 빨라야 한다. 따라서 50MHz의 샘플링 속도와 8 비트의 분해능을 갖는 A/D 변환기를 사용하였으며, 변환된 초음파 신호를 고속 처리하기 위해 Positive와 Negative Peak Detection 모드를 동시에 동작하도록 VHDL을 이용하여 설계하였다.

  • PDF

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화 (Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis)

  • 남동현;박영배;박영재;신상훈
    • 대한한의진단학회지
    • /
    • 제12권1호
    • /
    • pp.42-62
    • /
    • 2008
  • 연구배경과 목적: 지첨용적맥파는 광학기술을 이용하여 손가락 끝에서 혈액용적의 변화를 측정하여 맥파를 검출하는 기술로서, 지첨용적맥파에 대한 시간영역 파형분석을 통해 혈관의 노화정도를 파악할 수 있음은 이미 잘 알려진 사실이다. 이에 본 연구자는 시간영역 파형분석을 통해 혈관노화지표를 얻을 수 있다면, 주파수영역분석법을 통해서도 혈관노화지표를 얻을 수 있을 것으로 가정하였다. 본 연구에서는 주파수영역에서 혈관노화지표를 찾기 위해 건강한 성인들을 대상으로 지첨용적맥파를 측정하고 주파수영역에서 분석하여 고조파가 혈관노화 지표로서 활용될 수 있는가 여부를 결정하고자 한다. 연구방법: 건강인 390명(남자 174명과 여자 216명)을 대상으로 안정 후 앙와위에서 30초 동안 지첨용적맥파를 검출하였다. 검출한 맥파신호에서 기저선이 비교적 안정된 5-6개의 맥파주기를 선택하여 시간영역 파형분석을 통해 얻어지는 혈관노화지표인 승각시간, 경화지수, 반사지수, 가속도맥파를 구하였다. 주파수영역분석을 위해서는 빠른 퓨리에변환(FFT)를 실시하여 고조파 성분을 추출하였다. 특정점 검출을 위해서는 AcqKnowledge software의 peak detector 기능을 이용하였다. 연구결과: 표준화된 고조파 파워는 연령증가에 따라 유의하게 감소하였다; nPWR2 (r=-0.286, p<0.0001), nPWR3 (r=-0.482, p<0.0001), nPWR4 (r=-0.564, p<0.0001), nPWRS (r=-0.467, p<0.0001) 및 nPWR6 (r=-0.263, p<0.0001). 표준화된 고조파 파워의 logarithmic scale에서 연령증가에 따라 보다 강한 선형적인 감소가 나타났다; Ln(nPWR2) (r=-0.281, p<0.0001), Ln(nPWR3) (r=-0.492, P<0.0001), Ln(nPWR4) (r=-0.621, P<0.0001), Ln(nPWRS) (r=-0.487, P<0.0001) 및 Ln(nPWR6) (r=-0.273, P<0.0001). 승각시간, 반사지수, 경화지수를 독립변수로 한 중회귀분석에서 Ln(nPWR2) (R-squared=0.451), Ln(nPWR3) (R-squared=0.471) 및 Ln(nPWR4) (R-squared=0.432)는 비교적 잘 설명되었으나, Ln(nPWRS) (R-squared=0.232) 및 Ln(nPWR6) (R-squared=0.183)는 비교적 잘 설명되지 않았다. 결론: 건강인의 지첨용적맥파에서 기준 주파수로 표준화한 고조파 파워는 연령증가에 따라 감소였으며, 주파수영역분석이 가지는 특성을 고려해 볼 때 표준화된 고조파 파워는 기존의 시간영역 파형분석을 통해 얻어지는 혈관노화지표에 비해 잡음에 의한 오차가 보다 적을 것으로 기대된다. 따라서 우리는 표준화된 고조파 파워가 간편하고 용이하게 혈관노화를 반영하는 새로운 지표로서 활용될 수 있을 것으로 생각된다.

  • PDF