• Title/Summary/Keyword: Fast imaging

Search Result 460, Processing Time 0.029 seconds

The Sun Observed by Fast Imaging Solar Spectrograph of the 1.6 meter New Solar Telescope at Big Bear

  • Chae, Jong-Chul;Park, Hyung-Min;Ahn, Kwang-Su;Yang, Hee-Su;Park, Young-Deuk;Nah, Ja-Kyoung;Jang, Bi-Ho;Cho, Kyung-Suk;Cao, Wenda;Gorceix, Nicholas;Goode, Philip R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.25-25
    • /
    • 2010
  • With the aim of resolving important physical problems in the chromosphere of the Sun, we developed the Fast Imaging Solar Spectrograph for several years, and at last successfully installed it in the Coude room of the 1.6 meter New Solar Telescope at Big Bear in 2010 May. The instrument is an Echelle spectrograph with imaging capability based on slit scan, and can record two spectral bands (e.g., H alpha band and Ca II 8542 band) simultaneously. The early runs of the instrument produced data of high quality that are suited for the study of quiet Sun, filaments on the disk, prominences outside the limb, active regions and sunspots. We are ready to do good solar sciences using our own instrument, and will be able to do best sciences with the coming improvement of spatial resolution.

  • PDF

Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence (1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.491-496
    • /
    • 2018
  • The purpose of this study is to analyze the noise spectra in DWI (diffusion-weighted imaging) pulse sequences of 1.5 Tesla and 3.0 Tesla MRI, The ACR (American College of Radiology) phantom and noise spectrum were analyzed by FFT (fast Fourier transform) and TFFT (temporal frequency analysis) using WavePad sound editor version 8.13 (NCH software, Greenwood Village, CO, USA). Noise spectra, FFT and TFFT were analyzed for laboratory 1.5Tesla and 3.0Tesla DWI MR pulse sequences. The noise threshold of the frequency amplitude in the FFT and TFFT at 3.0Tesla compared to 1.5Tesla was between 1.5Tesla and -6 dB, and between 3.0Tesla and 0 dB, the DWI pulse sequence for the patient's noise reduction was appropriately MR examination needs to be applied.

Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface (나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법)

  • Kim, Tae-Eui;Kim, Hyun-Ji;Wi, Hun;Oh, Tong-In;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations, lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

A Rapid and Convenient Method for in Vivo Fluorescent Imaging of Protoscolices of Echinococcus multilocularis

  • Yang, Tao;Wang, Sibo;Zhang, Xuyong;Xia, Jie;Guo, Jun;Hou, Jixue;Zhang, Hongwei;Chen, Xueling;Wu, Xiangwei
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.2
    • /
    • pp.225-231
    • /
    • 2016
  • Human and animal alveolar echinococcosis (AE) are important helminth infections endemic in wide areas of the Northern hemisphere. Monitoring Echinococcus multilocularis viability and spread using real-time fluorescent imaging in vivo provides a fast method to evaluate the load of parasite. Here, we generated a kind of fluorescent protoscolices in vivo imaging model and utilized this model to assess the activity against E. multilocularis protoscolices of metformin (Met). Results indicated that JC-1 tagged E. multilocularis can be reliably and confidently used to monitor protoscolices in vitro and in vivo. The availability of this transient in vivo fluorescent imaging of E. multilocularis protoscolices constitutes an important step toward the long term bio-imaging research of the AE-infected mouse models. In addition, this will be of great interest for further research on infection strategies and development of drugs and vaccines against E. multilocularis and other cestodes.

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

Analysis of Eddy Current Effect in Magnetic Resonance Imaging Using the Finite Element Method (유한요소법에 의한 자기공명영상시스템에서의 와전류 영향 분석)

  • Lee, Jeong-Han;Gang, Hyeon-Su;Jo, Min-Hyeong;Mun, Chi-Ung;Lee, Gang-Seok;Lee, Su-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1999
  • Eddy current in MRI systems degrades gradient field linearity and distorts gradient waveform. When the waveform distortion is spatially variant, it is very difficult to perform special imaging techniques such as the echo planar imaging technique or the fast spin echo imaging technique. In this study, we have developed a new technique to estimate the distorted gradient waveforms at any points inside the imaging region using the finite element method. After obtaining the eddy-current-effect transfer function, which represents magnitude and phase characteristics of the gradient field at a particular point, we have used the transfer function to estimate the actual gradient waveforms at the point. To verify the proposed technique, we have compared the estimated gradient waveforms with the measured ones.

  • PDF

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

Effects and Limitations of Separating Overlapped Fingerprints Using Fast Fourier Transform (고속 푸리에 변환(fast Fourier transform, FFT)을 이용한 겹친지문 분리의 효과와 한계)

  • Kim, Chaewon;Kim, Chaelin;Lee, Hanna;Yu, Jeseol;Jang, Yunsik
    • Korean Security Journal
    • /
    • no.61
    • /
    • pp.377-400
    • /
    • 2019
  • Photography is the most commonly used method of documenting the crime and incident scene as it helps maintaining chain of custody (COC) and prove integrity of the physical evidence. It can also capture phenomena as they are. However, digital images can be manipulated and lose their authenticity as admissible evidence. Thus only limited techniques can be used to enhance images, and one of them is Fourier transform. Fourier transform refers to transformation of images into frequency signals. Fast Fourier transform (FFT) is used in this study. In this experiment, we overlapped fingerprints with graph paper or other fingerprints and separated the fingerprints. Then we evaluated and compared quality of the separated fingerprints to the original fingerprints, and examined whether the two fingerprints can be identified as same fingerprints. In the case of the fingerprints on graph paper and general pattern-overlapping fingerprints, fingerprint ridges are enhanced. On the other hand, in case of separating complicated fingerprints such as core-to-core overlapping and delta-to-delta overlapping fingerprints, quality of fingerprints can be deteriorated. Quality of fingerprints is known to possibly bring negative effects on the credibility of examiners. The result of this study may be applicable to other areas using digital imaging enhancement technology.

The Response of the Solar Chromosphere and Transition Region to a Coronal Rain Event

  • Kwak, Hannah;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.83.4-84
    • /
    • 2015
  • We report that a strong downflow event caused three-minute oscillations in the solar atmosphere. Our observations were carried out by using the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST) and the Interface Region Imaging Spectrograph (IRIS). Our main findings are as follows: (1) The strong downflow was seen at the $H{\alpha}$ absorption line at first, and then appeared at the Si IV and C II emission lines. It seems that the characteristics of the downflow are consistent with a coronal rain event. (2) After the event, oscillations of velocity were identified in the chromospheric lines and transition region lines. (3) The amplitudes of oscillations were 2km/s at Mg II line and 3km/s at C II and Si IV lines and decreased with time. (4) The period of the oscillation was 2.67 minutes at first, but gradually increased with time. Our findings are in agreement with Chae & Goode (2015)'s theory that of acoustic waves generated by a disturbance in a gravitationally-stratified medium.

  • PDF