• Title/Summary/Keyword: Faraday's law

Search Result 45, Processing Time 0.03 seconds

Analysis of Electrocoagulation Process using Faraday's Law (Faraday's Law에 의한 전기응집공정의 분석)

  • Kim, Hye-Sook;Yun, Young-Im;Cho, Eun-Jeong;Choi, Yun-Hee;Oh, Mi-Young;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.351-355
    • /
    • 2001
  • This research was carried out to find out the possibility of using Faraday's law in analyzing the electrocoagulation system. Bench-scale reactor equipped with aluminum electrode plates was operated using synthetic wastewater which received sodium chloride for conductivity adjustment. Phosphate was added to the wastewater to induce the precipitation with Al. The amount of aluminum dissolved from the electrodes could be predicted by Faraday's law with a difference less than 5%. This difference was greater at a higher electric current, probably due to the increased solution temperature. However, effect of pH on the dissolution of the aluminum was negligible. The result of this study suggested that the operating condition of electrocoagulation system could be developed using the Faraday's law when the pollutant concentration is given.

  • PDF

Electromagnetic effect by ignition current in vehicle (차량에서 Ignition current 변화에 따른 자기 유도에 의한 센서 출력 변화)

  • Lee, Dong-Ju;Kim, Cheol;Choe, Jang-Hyeon;Seong, Eun-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1611-1612
    • /
    • 2006
  • We are using the Faraday's electromagnetic law so as to improve our life in various industry fields. However, the side effect of the Faraday's law can be occurredin the sensors of the vehicle due to the high current flow such as Ignition. This effect is mainly caused by the shape of the wiring harness between sensor and high current load in the vehicle. To minimize the side effect by Faraday's law, three methods shall be considered in this paper (1) Pin definition of the sensor, (2) Pin definition of the high current load, (3) Wiring harness shape.

  • PDF

The Characteristic Analysis of E.M.F. Induced by Moving Normal Spot in a Cylindrical Superconducting Foil

  • Kim, Ho-Min;Bae, Joon-Han;Yoon, Yong-Soo;Chu, Yong;Ko, Tae-Kuk;Han, Tae-Su
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.99-104
    • /
    • 2000
  • The e.m.f. induced by a normal spot moving in a superconducting foil has been investigated by using the simulation and the experiment of a simple superconducting Power Supply. The induced e.m.f. has been derived theoretically from the magnetic field distribution within the spot. It is the sum of a DC component induced constantly by the Faraday's law during the spot's movement and a pulse component induced periodically by the flux conservation law at every electrical degrees 2$\pi$ radians. The DC component of the output voltage appears slightly nonlinear to the rotating speed, having values greater than the linear approximation values. The theoretical interpretation has been verified through experiment.

  • PDF

Prevention of Particulate Scale with a new winding method in the Electronic Descaling Technology (새로운 도선감는 방법을 사용한 전기장을 이용한 스케일 제거)

  • Kim, Gun-Woo;Ahn, Hee-Sub;Sohn, Chang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.180-186
    • /
    • 2000
  • This paper presents a new winding method in the electronic descaling(ED) technology. The ED technology Produces an oscillating electric field via the Faraday's law to Provide necessary molecular agitation to dissolved mineral ions. But present method gives another agitation force to mineral ions, which is Lorentz's force. Experiments were peformed at various Renolds number. A series of tests was conducted, measuring pressure drop across test section and the overall heat transfer coefficient as a function of time. In order to accelerate the rate of fouling, artificial hard water of 1000ppm $CaCO_3$ was used throughout the tests. The results show that the new method accelerates collision of mineral ions and improvs efficiency of system.

  • PDF

Prevention of Particulate Scale with a New winding Method in the Electronic Descaling Technology (새 도선 감는 방법을 적용한 전기장 이용 스케일 제거)

  • Son, Chang-Hyeon;Gu, Sang-Mo;Kim, Chang-Su;Kim, Geon-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.658-665
    • /
    • 2002
  • This paper presents a new winding method in electronic descaling (ED) technology. Conventional ED technology Produces an oscillating electric field via Faraday's law to provide the necessary molecular agitation to dissolve mineral ions. However, the proposed method produces an additional agitation force for mineral ions, called Lorentz's force. Experiments were performed using various Renolds numbers. A series of tests was conducted to measure the pressure drop across the test section and the overall heat transfer coefficient as a function of time. In order to accelerate the rate of fouling, artificial hard water, 1000ppm CaCO$_3$, was used throughout the tests. The results show that the new winding method accelerates the collision of the mineral ions, thereby improving the system efficiency. The present study can develope more effective fouling-removing equipment with change of estabishment method of coil.

A Study on the Disk Type MHD Generator Using a Shock Tube (충격파관을 이용한 DISK형 MHD발전기에 관한 연구)

  • 배철오;신명철;김윤식;길경석
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.447-453
    • /
    • 1999
  • In MHD power generation system, enthalpy of the working gas is convened to electric power directly through expansion in generator channel. It means that electric power can be generated without a moving mechanical linkage such as turbine blades. The principle of MHD generation is based on Faraday'law of induction that eletromotive force(u$\times$B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In this paper, helium gas seeded with cesium is used as working gas. There are two types of generator in MHD generation; linear type faraday and disk type hall generator. Rogowski coils having the bandwidth of the 100(Hz) ~ 20(kHz) were used for measuring current flowing MHD disk channel. Optimum load resistor value of the MHD generator studied was 2.5[$\Omega$]. Disk type hall generator's generation performance is the main target of this paper, which superiors to linear type Faraday generator in many points. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

A Study on Enthalpy Extraction Rate and Isentropic Efficiency of the Disk Type Generator using a Shock Tube (충격파관을 이용한 DISK형 MHD발전기의 엔탈피추출율과 단열효율에 관한 연구)

  • Bae, C.O.;Kim, Y.S.;Park, Y.S.;Shin, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1981-1983
    • /
    • 1998
  • The principle of the MHD generation is based on Faraday's law of induction that a eletromotive force(u ${\times}$ B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In MHD power generation system, enthalpy of the working gas is converted to electric power directly through expansion in generator channel. It means that electric power can be generated without moving mechanical linkage such as turbine blades. There are two types in the MHD generator; linear type Faraday and disk type hall generator. Disk type hall generator is the main target of this paper. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

Smart Passive System Based on MR Damper (MR댐퍼 기반의 스마트 수동제어 시스템)

  • Cho, Sang-Won;Jo, Ji-Seong;Kim, Chun-Ho;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.51-59
    • /
    • 2005
  • Magnetorheological(MR) dampers are one of the most promising semi active control devices, because they have advantages such as small power requirement, reliability, and low price to manufacture. To reduce the responses of structures with MR dampers, a control system including power supply, controller, and sensors is required. However, when a mount of MR dampers are used to a large?scale civil structure such as cable stayed bridges, the control system becomes complex. Therefore, it is not easy to install and maintain the MR damper based control system. To resolve above difficulties, This paper proposes a smart passive system that consists of a MR damper and an electromagnetic induction(EMI) system. According to the Faraday’s law of induction, EMI system that is attached to the MR damper produces electric energy. The produced energy is supplied to the MR damper. Thus, the MR damper with EMI system does not require any power at all. Furthermore, the induced electric energy is proportional to external loads like earthquakes, which means the MR damper with EMI system is adaptable to external loads without any controller and corresponding sensors. Therefore, it is easy to build up and maintain the proposed smart passive system.

자장센서의 지상기능시험 데이터 분석을 통한 건전성 진단

  • Lee, Seon-Ho;Kim, Jin-Hui
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.189.1-189.1
    • /
    • 2012
  • 자장센서는 인공위성에 장착되어 궤도환경에서의 지자기장을 측정하는 센서로서 위성체의 자세결정과 자세제어 등에 활용된다. 일반적으로 자장센서는 원리와 응용범위에 따라 그 종류가 광범위하다. 응용되는 자기현상적으로 분류하면 Faraday 전자기 유도법칙을 이용한 방식, Hall Effect를 이용한 방식, 감지코일의 인덕턴스 변화와 와전류효과를 이용한 방식, 자속분포의 변화에 의한 유도기전력의 변화를 이용한 방식, 자기저항 변화효과를 이용한 방식 등이 있다. 그 중에서도 Faraday's Law를 이용하는 Fluxgate 자장센서가 구조가 비교적 간단하고 경량이며, 높은 신뢰성과 안정성을 가진다. 실제 위성을 발사하기전 지상에서는 위성체를 조립하고 전자파, 진동, 열진공 등과 같은 다양한 환경시험을 수행하는데, 이때 각 환경시험 수행을 전후로 자장센서의 극성시험, 응답시험 등과 같은 기능시험을 수행한다. 본 논문은 다양한 환경시험을 통해 수행한 Fluxgate 자장센서 기능시험 데이터에 대한 추이를 분석하여 위성 발사전 지상에서의 자장센서의 상태와 건전성을 진단하는 방법에 대하여 소개한다.

  • PDF

A New Method on the Prediction of Corrosion Resistance of Reinforced Concrete Using Accelerated Potentiometric Corrosion Method (전위차 부식촉진법을 이용한 철근 콘크리트의 내부식성 예측을 위한 새로운 기법 연구)

  • 오병환;조윤구;차수원;정원기
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.201-209
    • /
    • 1996
  • Recently, large scale concrete structures exposed to severe environment are increasingly built in various locations. The corrosion may severely affect the durability and service life of such a concrete structure. It is, therefore, necessary to develop durable concrete to enhance the corrosion resistance. The corrosion resistance of concrete can be identified through accelerated corrosion test. The purpose of the present paper is, therefore, to devise a reasonable and accurate method to predict the amount of corrosion of reinforcing steels. The proposed method which is basically based on the concept of Faraday's Law, determines the corroded amount of a rebar according to accelerated corrosion time. The corrosion is accelerated by employing the potentiometric corrosion test arrangement. The effects of admixtures in concrete including fly ash and silica fume have been also studied to explore the relative corrosion resistance of concrete.