• Title/Summary/Keyword: Fan-motor

Search Result 252, Processing Time 0.023 seconds

Analysis of Switched Reluctance Motor based on 3D Equivalent Magnetic Circuit Network Method of New Shape Element (새로운 요소를 이용한 SRM의 3차원 등가자기회로망 해석)

  • Kim, Wa-Sung;Chun, Yon-Do;Kim, Youn-Hyun;Lee, Ju;Kim, Suk-Tae;Lee, Chol-Jik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.570-573
    • /
    • 2001
  • This paper presents the characteristics of Switched Reluctance Motor (SRM) based on 3D Equivalent Magnetic Circuit Network Method (3D EMCNM). 3D EMCNM supplements magnetic equivalent circuit by numerical technique using distributive magnetic circuit parameters. However in case of SRM the previous 3D EMCNM which uses fan shape element is not proper for analysis. This paper solved this problem by developing the trapezoid element and verified the validity of the suggested element by comparing the results of 3D EMCNM with 2D FEM.

  • PDF

Characteristics Analysis of Outer Rotor Type BLDC Motor according to Permanent Magnet Shade and Input Voltage Waveform (Permanent Magnet형상과 입력전압 파형에 따른 BLDC 전동기의 동특성해석)

  • Kim, Kyung-Ho;Choi, Geo-Seung;Kim, Myoung-Su;Chung, Koon-Seok;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.924-926
    • /
    • 2001
  • This paper presents the characteristics of current harmonics and torque ripple of Brushless DC motor, which is developed the fan blower of vehicles, according to permanent magnet shape input voltage wave form. To investigate the torque ripple and the phase current harmonics, these characteristics is analysed and compared the experimental results. In the process of analysis, FEM is introduced and computed a transient state torque of BLDC with a sinusoidal and a PWM wave voltage.

  • PDF

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

Manufacturing Driver and Measuring Performance of Disk type Single Phase Switched Reluctance Motor (DSPSRM) (디스크형 단상 SRM의 구동드라이브 제작과 성능 측정)

  • Lee, Jong-Han;O, Yeong-Ung;Lee, Eun-Ung;Lee, Min-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.15-19
    • /
    • 2000
  • The main advantages of DSPSRM lie in the simple robust construction, low manufacturing cost and simple driving circuit. Especially, it is possible to make shortly the axial length of DSPSRM. therefore, it is suitable to setup this motor in a narrow space. For practical use, prototype of DSPSRM was already manufactured. In this paper, we explain driving method and design driving circuit of DSPSRM. And then speed, torque and efficiency are measured. As a result of measurement, the torque was constant at normal speed and the speed was linearly increased as the current increase. Therefore, we verify that DSPSRM is suitable for low-speed fan load.

  • PDF

Characteristics Analysis of Outer Rotor Type BLDC Motor according to Input Voltage Waveform (외전형 BLDC 전동기의 입력전압 파형에 따른 특성해석)

  • Kim Kyung Ho;Choi Geo Seung;Kim Myoung Su;Cho Yun Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.22-24
    • /
    • 2001
  • This paper presents the characteristics of current harmonics and torque ripple of Brushless DC motor, which is developed the fan blower of vehicles, according to input voltage waveform. To investigate the torque ripple and the phase current harmonics, these characteristics is analysed and compared the experimental results. In the process of analysis, FEM is introduced and computed a transient state torque of BLDC with a sinusoidal and a PWM wave voltage.

  • PDF

A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone (고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구)

  • Kim, SooYeon;Kim, Jin-Seon;Sung, Jin-Ho;Han, Bangwoo;Kim, Yong-Jin;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

Localization Development of Axial Fan for KM-SAM Multi-function radar (KM-SAM 다기능레이더용 축류형 송풍기 국산화 개발)

  • Lee, Gyeong-Chan;Choi, Young-Ho;Lee, Kowan-Woo;Seo, Dae-Sue
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • This paper describes the localization development of an axial fan for KM-SAM multi-function radar. The multi-function radar, which is constantly affected by the external environment, is a key instrument for detecting and tracking low and medium altitude threat targets. Operating this equipment smoothly requires a fan for controlling the internal temperature and humidity. Presently, all such fans are imported. To solve these problems, localization development research was proposed. The development of localization includes analysis of requirements through review of related technical reports such as original equipment and system equipment specification, prototype design, and verification of design requirement through performance test and environmental test. The study results are described. The blower consisted of an axial fan with guide vanes and the motor was designed to generate a maximum airflow of 970 CFM and a wind pressure of 4.8 IWG. Six prototypes were manufactured for performance evaluation. In addition, for reliable data acquisition, AC power supply, fan performance tester and data acquisition equipment were designed and tested. All prototypes were verified as having design requirements equal to or better than those of imports.

The Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층 공동주택 국소배기용 입상덕트의 배기성능평가)

  • Kwon, Yong-Il;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

Optimal Design of Stator Shape for Cogging Torque Reduction of Single-phase BLDC Motor (단상 BLDC 전동기의 코깅토크 저감을 위한 고정자 형상 최적설계)

  • Park, Young-Un;So, Ji-Young;Chung, Dong-Hwa;Yoo, Yong-Min;Cho, Ju-Hee;Ahn, Kang-Soon;Kim, Dae-Kyong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1528-1534
    • /
    • 2013
  • This paper proposes the optimal design of stator shape for cogging torque reduction of single-phase brushless DC (BLDC) motor with asymmetric notch. This method applied size and position of asymmetric notches to tapered teeth of stator for single-phase BLDC motor. Which affects the variation of the residual flux density of the permanent magnet. The process of optimal design included the extraction of the sampling point by using Latin Hypercube Sampling(LHS), and involved the creation of an approximation model by using kriging method. Also, the optimum point of the design variables were discovered by using the Genetic Algorithm(GA). Finite element analysis was used to calculate the characteristics analysis and cogging torque. As a result of finite element analysis, cogging torque were reduced approximately 39.2% lower than initial model. Also experimental result were approximately 38.5% lower than initial model. The period and magnitude of the cogging torque were similar to the results of FEA.

A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time (풍량 및 운전시간 제어 방폭 배풍기 인버터 단자함 개발에 관한 연구)

  • Yoo, DongJoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.187-192
    • /
    • 2018
  • This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.