• Title/Summary/Keyword: Falling test

Search Result 376, Processing Time 0.028 seconds

An Acoustic Study of the Pre-nuclear Intonation Pattern in Korean (국어 머리 억양의 음향 음성학적 연구)

  • Lee Ho-Yeong
    • MALSORI
    • /
    • no.33_34
    • /
    • pp.99-110
    • /
    • 1997
  • This paper aims to investigate the internal structure of the pre-nuclear intonation pattern and to discuss the inventory and usage of the phrasal tone in Korean based on the acoustic analysis of 80 test sentences. CSL Model 4300 was used for recording and filing, and Multi-speech Model 3700 for analysis. It is shown that the pre-nuclear intonation pattern is composed of one or more phrasal tones, the intonation pattern of the rhythm nit. It is observed that the second phrasal tone begins with a higher pitch than the first one and that the phrasal tones following the second one begins with a lower pitch than the preceding phrasal tone unless a certain word is emphasized. In addition to Level, Rising, Falling, and Rise-Fall phrasal tones already established in Lee (1990, 1991, 1996), Pall-Rise and Rise-Fall-Rise phrasal tones are newly established in this paper. It is observed that Rising and Rise-Fall-Rise phrasal tones are most frequently used as the first phrasal tone of a pre-nuclear intonation pattern and the falling tone as the last phrasal tone, and that Fall-Rise and level tones appear most frequently in the middle of a pre-nuclear intonation pattern.

  • PDF

A Predictive Model of Fall Prevention Behaviors in Postmenopausal Women (폐경 후 여성의 낙상예방행위 예측모형)

  • Jang, Hyun-Jung;Ahn, Sukhee
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.5
    • /
    • pp.525-533
    • /
    • 2014
  • Purpose: This study was done to propose and test a predictive model that would explain and predict fall prevention behaviors in postmenopausal women. The health belief model was the theoretical basis to aid development of a nursing intervention fall prevention program. Methods: Data for 421 postmenopausal women were selected from an original data set using a survey design. The structural equation model was tested for 3 constructs: modifying factors, expectation factors, and threat factors. Expectation factors were measured as relative perceived benefit (perceived benefit minus perceived barrier), self-efficacy, and health motivation; threat factors, as perceived susceptibility (fear of falling) and perceived severity (avoiding activity for fear of falling); and modifying factors: level of education and knowledge about fall prevention. Data were analyzed using SPSS Windows and AMOS program. Results: Mean age was 55.7 years (range 45-64), and 19.7% had experienced a fall within the past year. Fall prevention behaviors were explained by expectation and threat factors indicating significant direct effects. Mediating effect of health beliefs was significant in the relationship between modifying factors and fall prevention behaviors. The proposed model explained 33% of the variance. Conclusion: Results indicate that fall prevention education should include knowledge, expectation, and threat factors based on health belief model.

Experimental Correlation of Wettability for Micro-scale Hatched Tubes (미소해칭 전열관의 젖음률에 대한 실험적 상관식)

  • 김진경;박찬우;이경엽;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The objectives of this paper are to develop a new method of wettability mea-surement and to study the effect of surface roughness on the wettability in a $H_2O$/LiBr falling film absorber. Two absorber tubes with micro-scale roughness and a bare tube are tested in a falling film absorber installed in a test rig. Inlet solution temperature, concentration and mass flow rate are considered as key parameters. A new method is proposed to estimate the wettability of a tube by measuring a minimum mass flow rate to wet the tube completely. The wettability for the structured surfaces was higher than that for the bare tube. The wettability decreased linearly along the vertical location. The wettability increased with increasing the solution temperature and the solution mass flow rate. The experimental correlations of the wettability for the bare and the micro-hatched tubes were developed with error bands of$\pm20%\;and\;\pm10%$, respectively. This work can be used in the design of absorbers with micro-scale roughness.

Nonlinear Subgrade Model-Based Comparison Study between the Static and Dynamic Analyses of FWD Nondestructive Tests (노상의 비선형 모델에 근거한 비파괴 FWD 시험에 있어 정적과 동적 거동의 비교연구)

  • Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.19 no.1
    • /
    • pp.73-80
    • /
    • 2017
  • PURPOSES : This paper presents a comparison study between dynamic and static analyses of falling weight deflectometer (FWD) testing, which is a test used for evaluating layered material stiffness. METHODS: In this study, a forward model, based on nonlinear subgrade models, was developed via finite element analysis using ABAQUS. The subgrade material coefficients from granular and fine-grained soils were used to represent strong and weak subgrade stiffnesses, respectively. Furthermore, the nonlinearity in the analysis of multi-load FWD deflection measured from intact PCC slab was investigated using the deflection data obtained in this study. This pavement has a 14-inch-thick PCC slab over fine-grained soil. RESULTS: From case studies related to the nonlinearity of FWD analysis measured from intact PCC slab, a nonlinear subgrade model-based comparison study between the static and dynamic analyses of nondestructive FWD tests was shown to be effectively performed; this was achieved by investigating the primary difference in pavement responses between the static and dynamic analyses as based on the nonlinearity of soil model as well as the multi-load FWD deflection. CONCLUSIONS : In conclusion, a comparison between dynamic and static FEM analyses was conducted, as based on the FEM analysis performed on various pavement structures, in order to investigate the significance of the differences in pavement responses between the static and dynamic analyses.

Capless Low Drop Out Regulator With Fast Transient Response Using Current Sensing Circuit (전류 감지 회로를 이용한 빠른 과도응답특성을 갖는 capless LDO 레귤레이터)

  • Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.552-556
    • /
    • 2019
  • This paper present a capless low drop out regulator (LDO) that improves the load transient response characteristics by using a current regulator. A voltage regulator circuit is placed between the error amplifier and the pass transistor inside the LDO regulator to improve the current characteristics of the voltage line, The proposed fast transient LDO structure was designed by a 0.18 um process with cadence's virtuoso simulation. according to test results, the proposed circuit has a improved transient characteristics compare with conventional LDO. the simulation results show that the transient of rising increases from 1.954 us to 1.378 us and the transient of falling decreases from 19.48 us to 13.33 us compared with conventional capless LDO. this Result has improved response rate of about 29%, 28%.

Study on Development of Medical Software Evaluation Criteria (의료용 소프트웨어의 평가기준 개발에 관한 연구)

  • Yang, Hae-Sool;Pyon, Ung-Bum;Lee, Jeong-Rim;Ryu, Gyu-Ha
    • The KIPS Transactions:PartD
    • /
    • v.10D no.5
    • /
    • pp.781-792
    • /
    • 2003
  • We medical software is becoming important means to secure competitive power of medical service by explosive increase of medical device based on software, and the quality of medical service is affected to quality of medical software as well as medical devices. But domestic related study and development is not sufficient for quality of medical software, and a falling-off in medical software quality can induce a falling-off in quality of medical service. Therefore, it is necessary to raise qualitative level of medical service by progress and quality improvement of medical devices. Therefore, in this paper, we developed test module and qualify inspection table which can test medical software and produce result based on ISO/1EC 12119.

A Comparison of Assessment Tools for Prediction of Falls in Patients With Stroke (뇌졸중 환자의 낙상 예측을 위한 평가도구 비교)

  • Won, Jong-Im
    • Physical Therapy Korea
    • /
    • v.21 no.2
    • /
    • pp.37-47
    • /
    • 2014
  • Falls are common after stroke and most frequently related to loss of balance while walking. Consequently, preventing falls is one of the goals of acute, rehabilitative, and chronic stroke care. The purpose of this study was to investigate the incidence and risk factors of falls and to determine how well the Falls Efficacy Scale (FES), Timed Up and Go test (TUG), and Berg Balance Scale (BBS) could distinguish between fallers and non-fallers among stroke patients during inpatient rehabilitation. One hundred and fifteen participants with at least 3 months post-stroke and able to walk at least 3 m with or without a mono cane participated in this study. Fifty-four (47%) participants reported falling, and 15 (27.8%) had a recurrent fall. Logistic regression analysis for predicting falls showed that left hemiplegia [odds ratio (OR)=4.68] and fear of falling (OR=5.99) were strong risk factors for falls. Fallers performed worse than non-fallers on the FES, TUG, and BBS (p<.05, p<.01, respectively). In the receiver operator characteristic curve analysis, the TUG demonstrated the best discriminating ability among the three assessment tools. The cut-off score was 22 seconds on the TUG for discriminating fallers from non-fallers (sensitivity=88.9%, specificity=45.9%) and 27 seconds for discriminating recurrent fallers from single fallers and non-fallers (sensitivity=71.4%, specificity=40.2%). Results suggest that there is a need for providing fall prevention and injury minimization programs for stroke patients who record over 22 seconds on the TUG.

A Study on Characteristics of Strength Increase and Bearing Capacity in Dredged and Reclaimed Soil due to Desiccation Shrinkage (준설토의 건조수축에 의한 강도증가 특성과 지지력에 관한 연구)

  • Yoo, Nam-Jae;Lee, Jong-Ho;Lee, Myung-Woog;Kim, Hyun-Joo
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.101-111
    • /
    • 2000
  • This research is results of experimental and numerical works on characteristic of strength increase and bearing capacity in dredged and reclaimed soil due to desiccation shrinkage. For a soil sampled from southern coastal area in Korea, basic soil property tests and standard consolidation test with falling head permeability tests were carried out to obtain consolidational characteristics of soil. Double cone penetration test, laboratory vane test and unconfined compression test were also performed to investigate the change of shear strength with degree of desiccation. Model tests were performed in 1G environment and 30G level artificially accelerated condition by using the centrifuge model test facilities to investigate the bearing capacity of desiccated ground. Test results were analyzed by using the theoretical and load-settlement characteristics method proposed by Meyehof & Hanna(1978). On the other hands, the numerical technique, using the finite strain consolidation theory considering the effect of desiccation was used to estimate the appropriate time of using heavy construction equipments in field with respect to strength increase due to desiccation.

  • PDF

다목적 콘 관입시험기의 활용

  • Bae, Myeong-Ho;Yoon, Hyung-Koo;Kim, Ju-Han;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.163-170
    • /
    • 2010
  • Today, In-Situ testing for measureing geotechnical characterization are divided by Cone Penetration Test, Standard Penetration Test and Dilatometer Test, and will vary depending on soil conditions have been applied (Korea Geotechnical Engineering, 2006). However, these methods can be applied on sand or soft clay soil. Now, many studies are progressing for evaluating the stiffness characteristic of rocks and IGM. and Nam moon suk(2006) did Texas Cone Penetrometer Test for designing field penetration pile intruded at rocks and IGM. but, reliability of Texas Cone Penetration Test has confidence limits because TCPT is testing in Texas centrally, and energy dose not measure Woojin Lee, etc. (1998) did calculate Standard Penetration Test Hammer's dynamic energy efficiency by using dongjaeha analyzer. this research, we installed strain gage and accelerometer for supply existing equipment, and develop MCP that can use variety soils. this thesis, we measured energy at head and tip of Rod for evaluating energy that transport at free falling. As a result, Energy differences are occurred at head and tip of Rod.

  • PDF

Effects of Task-Oriented Training With Functional Electrical Stimulation on Cervical Spinal Cord Injury Patients' Hand Function: A Single-Subject Experimental Design (기능적 전기 자극을 병행한 과제 지향적 훈련이 경수 손상 환자의 손 기능에 미치는 영향: 개별사례 연구)

  • Ko, Seok-Beom;Park, Hae Yean;Kim, Jong-Bae;Kim, Jung-Ran
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.1
    • /
    • pp.63-77
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the effects of task-oriented training with functional electrical stimulation on hand function in incomplete cervical cord injury. Method : The subjects of the study were 3 adults diagnosed as incomplete cervical cord injury. The design of this study was ABA single-subject research design to compare dominant hand function of before and after intervention and detect individual effects. The experiment consisted of 30sessions, in which baseline process A1 and A2 were implemented 5 sessions each for 10sessions. Intervention B was implemented 20 sessions. The dependent variable was converted to the change of hand function every session, and Canadian Occupational Performance Measure (COPM), Jebsen-Taylor Hand Function Test(JTHFT), Wolf Motor Function Test(WMFT) were selected for outcome measurements. Result analysis was suggested through visual analysis using a graph and comparison of pre, post and follow-up intervention measurements. Results : As a result, the quality and quantity of dominant hand function increased during intervention B compared to the baseline A1 for all subjects. Baseline A2 was also maintained without training. Additionally, JTHFT, WMFT and COPM scores demonstrated improvement and maintain. The follow up JTHFT and WMFT showed increased required time on all subjects and decrease or maintain task performance and satisfaction in COPM. Conclusion : The task-oriented training with function electrical stimulation in this study has been positive effects on hand function and task performance and satisfaction.