• Title/Summary/Keyword: Fall-of-potential

검색결과 236건 처리시간 0.02초

봉상접지전극의 접지임피던스의 주파수의존성의 분석 (Analysis of the Frequency Dependent Characteristics of Ground Impedance of a Ground Rod)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.426-432
    • /
    • 2004
  • This paper presents a systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection system and intelligent power equipments. The measurement and analysis system of ground impedance is based on a computer aided technique. The magnitude and phase of ground impedance were determined by the novel measurement and analysis using the revised fall-of-potential method. The ground impedances of the ground rod of 50 m long are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. Although the steady-state ground resistance of the ground rod of 50 m was less than that of the ground rod of 10 m, the ground impedances of the ground rod of 50 m over the frequency range of more than 60 kHz were much greater than those of the ground rod of 10 m. Furthermore, the equivalent circuit model based on the measured data was proposed. and the calculated results were in approximately agreement with the measured data.

접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석 (Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

The history of slip and fall accidents

  • Son, D.H.
    • 대한인간공학회지
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 1990
  • Recorded injury identified the role of falls in producing injury througout all segments of the nation. The Economic and social costs arising from falls has been established in numerous sources, both nationally and from the intermational literature. Recorded injury also indicated the potential features of falls, the need for a basic understanding of the energy exchange mechanism involved and the subsequent rehabilitation processes required. It appears unlikely that any other major cause of injury has an etiology so little researched and consequently, so little understood, which in turn has prevented the development of an intervention strategy or a scientically based control technology of falls. This paper will emphasize how the postural changes of foot are related to slip/fall severity in different environmental conditions. Lidewise, we will examine the whole slip/fall cycle through the biomechanical parameters involved in a range of walking speed and floor slipperiness

  • PDF

Litter Processing in Tropical Headwater Streams : Potential Importance of Palm Fruit Fall and Frond Fall

  • Covich, Alan P.
    • The Korean Journal of Ecology
    • /
    • 제23권2호
    • /
    • pp.113-116
    • /
    • 2000
  • Different phenological patterns of leaf and fruit fall among native and non-native riparian species provide a spatially and temporally heterogeneous series of alternative food resources for detritivores. Relatively little is known about qualitative differences among these different riparian species. Rates of litter inputs, decomposition, and retention for different sources of riparian litter require long-term documentation. Species of freshwater shrimps, crabs. insects. and gastropods are known to consume a wide range of litter inputs but how these dynamic food webs function under changing climatic and land-use conditions is unknown, especially in tropical streams. On-going studies in the Luquillo Experimental Forest. Puerto Rico provide an example of how inputs of fronds and fruits from palms (Prestoea montana) serve as important foods and microhabitat for species of freshwater crabs and shrimp. Native riparian species such as Prestoea montana are commonly distributed in the Luquillo Mountains especially along steep slopes and stream banks. After tropical storms with high winds, the large fronds from these native riparian trees provide important inputs of leaf litter to the stream food web. In some streams, the input of ripe fruit from non-native trees such as Java plum (Syzigium jambos) also provides a major source of detrital food resources, especially during periods when fruit fall from native species of palms may be limited.

  • PDF

Enhanced 3D Residual Network for Human Fall Detection in Video Surveillance

  • Li, Suyuan;Song, Xin;Cao, Jing;Xu, Siyang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권12호
    • /
    • pp.3991-4007
    • /
    • 2022
  • In the public healthcare, a computational system that can automatically and efficiently detect and classify falls from a video sequence has significant potential. With the advancement of deep learning, which can extract temporal and spatial information, has become more widespread. However, traditional 3D CNNs that usually adopt shallow networks cannot obtain higher recognition accuracy than deeper networks. Additionally, some experiences of neural network show that the problem of gradient explosions occurs with increasing the network layers. As a result, an enhanced three-dimensional ResNet-based method for fall detection (3D-ERes-FD) is proposed to directly extract spatio-temporal features to address these issues. In our method, a 50-layer 3D residual network is used to deepen the network for improving fall recognition accuracy. Furthermore, enhanced residual units with four convolutional layers are developed to efficiently reduce the number of parameters and increase the depth of the network. According to the experimental results, the proposed method outperformed several state-of-the-art methods.

입원환자의 낙상발생 연구 자료원으로서의 국제간호실무분류체계 기반 전자간호기록의 유용성 (Exploring the Utility of the ICNP based Electronic Nursing Records as a Research Source for Inpatients' Falls)

  • 조인숙;박인숙;김은만
    • Perspectives in Nursing Science
    • /
    • 제5권1호
    • /
    • pp.33-43
    • /
    • 2008
  • Objective: This study explored the reuse of data captured into an electronic nursing record system using the International Classification for Nursing Practice to support nursing research of inpatient's falls. Methods: Risk factors relevant to inpatients falls ;n an acute setting were identified from the literature review. Four risk assessment tools and two risk identification studies were selected. To examine the availability of coded data in an electronic nursing record system for the identified fall fisk factors, we reviewed 11.319 hospital-day records of 118 patients who were reported by the self-report system. Results: We identified 24 fall risk factors of five categories from the literature review, which were used to identify the standard nursing statements addressing fall risks. One hundred thirty five nursing statements were searched from the hospital's nursing data dictionary of statements and were matched with 14 fall fisk factors. Using the 135 statements. we found that mental status, catheter of drip in situ, abnormal gait, insomnia, surgical procedure. and dizziness/vertigo appeared frequently in the nursing records of inpatients with fall s. Also we found 6 risk factors more through the record review. Conclusion: The electronic records would be a good research source for inpatients' falls. Specifically international classification for nursing practice based nursing record system has the potential for promoting clinical researches.

  • PDF

송전철탑 부근의 대지전위 억제를 위한 이격거리 산정모델 연구 (A Study on Separation Distance Calculation Model for Limitation of Earth Potential Rise Nearby Tower Footings)

  • 최종기;조환구;김태영;이동일
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.179-183
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system. In this paper, an analytical formula to calculate the requried sepeartion distance from the faulted tower has been derived.

노인가정의 낙상사고 위험 환경요인 (Home Environmental Hazards of Falling Accident in the Elderly)

  • 박영혜;문정순
    • 보건교육건강증진학회지
    • /
    • 제22권4호
    • /
    • pp.203-213
    • /
    • 2005
  • Purpose: To assess the environmental hazards of falling accident in the homes of the elderly. Method: 222 homes of the elderly were assessed by the home environmental Checklist from May to July in 2003. Results: The mean score of home environmental hazards for fall were 13.19 with the highest score being 49, ranging from 4 to 24. The bathroom was the most hazardous place in the home, porch came next bedroom, kitchen, living room and stair followed them. The floor surface such as finishes and non-skid mats was the most hazardous interior factor in the home, using bathroom came next furniture and illumination followed them. The floor surface such as finishes and non-skid mats in the bathroom, kitchen, living room and porch, illumination of bedroom and stair were the most prevalent hazards in the home of interior. Of the 49 potential hazards, bathroom grab bar was the most prevalent one with 89.9%, and non-skid rugs in the porch, bathroom and kitchen, safety of dinner table, the threshold and furniture of porch, and illumination of bedroom were prevalent more than half of the home under assessing. Men, living in the separate house or villa with stairs were in more hazardous environments. Conclusion: To reduce the potential hazards of fall accident in the home, improving hazards relating to floor surface such as slip resistance surface and mats is important specially those of the separate house or villa with stairs.

수직 접지전극의 접지임피던스 측정에서 도전유도에 의한 오차 평가 (Evaluation of Errors Due to Earth Mutual Resistance in Measuring Ground Impedance of Vertically-driven Ground Electrode)

  • 최종혁;최영철;이복희
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1778-1783
    • /
    • 2009
  • Ground impedance for the large grounding system is measured according to the IEEE Standard 81.2 which is based on the revised fall-of-potential method of installing auxiliary electrode at a right angle. When the auxiliary electrodes are located at an angle of $90^{\circ}$, the ground impedance inevitably includes the error due to earth mutual resistance. In this paper, in order to accurately measure the ground impedance of vertically-driven ground electrodes, error rates due to earth mutual resistance are evaluated by ground resistance and ground impedance measuring devices and compared with calculated values. As a result, the measured results are in good agreement with the computed results considering soil layer with different resistivity. The error rates due to earth mutual resistance decrease with increasing the length of ground electrode in the case that the ratio of the distance between the ground rod to be measured and the auxiliary electrodes to the length of ground electrode(D/L) is same. The ground impedance should be measured at the minimum distance between the auxiliary electrodes that will have an estimated measurement accuracy due to earth mutual resistance.

Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis)

  • 백승현;김경철;최종기;이일무;백남웅
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.181-187
    • /
    • 2004
  • 3상 4선식 배전계통을 채용하는 우리나라는 비선형 부하의 증가로 중성선에는 많은 중성선 고조파 전류가 관측되고 있다. 또한 접지 임피던스는 고조파가 있는 중성선 전류에 영향 끼친다고 알려져 있다. 전위 강하법에 따라 현장에서 실측한 고조파 전류와 전압을 측정하고, Pattern Search 기법으로 고조파 해석용 접지 임피던스를 모델링 하였다. 여기서 구한 임피던스 모델은 현장 시험에 의한 임피던스 모델과 비교하여 유사한 결과를 얻었고, 접지 시스템의 고조파 및 과도 응답 특성을 평가하는데 활용될 것으로 사료된다.