• Title/Summary/Keyword: Failure wave

Search Result 312, Processing Time 0.025 seconds

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

Study of Stability for Armor Weight of Stand-alone Caisson at Yongsu Wave Power Plant (용수 파력발전소 사례에서 독립 케이슨의 피복석 안정성 연구)

  • Kim, Gunwoo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.478-484
    • /
    • 2019
  • The submarine cable for Yongsu wave power plant was cut in 2014 winter. This study investigated the probability of high-wave occurrence exceeding the 50-year return period and the underestimation of armor unit weight used to protect the cable. The observation data from KMA buoy and the hindcast wave data were reviewed to determine the return period of wave height during the winter. In order to investigate the armor unit weight of cable-protection, we calculated the required weight of armor unit using not only Design Standard for Harbor and Fishery Port, but also the previous researches for the wave with large incident angle. As a result, it appeared that the high wave exceeding the 50-year return period did not occur during the winter of 2014 and the armor unit weight of the cable protection was not sufficient to sustain the obliquely incident wave, which induced the cable protection failure.

Reliability Analysis of the Long Caisson Breakwater Considering to the Wave Force Reduction Parameter (파력감소계수를 고려한 장대케이슨 방파제의 신뢰성해석)

  • Lee, Gee Nam;Park, Woo Sun;Kim, Dong Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.2
    • /
    • pp.121-127
    • /
    • 2017
  • The actual wave is multi-direction irregular wave. In the case of a long structure, a reduction effect of the wave occurs. In this study, in order to grasp the extent to which these influences contribute to the failure probability and compare the existing modular breakwaters to the stability, we used existing modular breakwaters and long caisson breakwaters using wave force reduction parameter to analysis the reliability. As a result, the reliability index of the long caisson breakwater was higher than that of the existing modular caisson breakwater, and it was confirmed that the significant wave height of the design variables had the highest influence. In addition, the reliability analysis was performed according to the change of the mean value of the variables used in the calculation of the wave force reduction parameter. It is confirmed that the relationship between each variable value and the wave force reduction parameter appears in the analysis results.

The Determinants of Corporate Training in Korea - Market Failure and State Intervention - (한국 기업의 교육훈련 결정요인 - 시장실패와 정부 개입을 중심으로 -)

  • Kim, Ahn-Kook
    • Journal of Labour Economics
    • /
    • v.31 no.1
    • /
    • pp.105-133
    • /
    • 2008
  • Focusing market failure and state intervention, this article analyzes the determinants of corporate training in Korea. Analysing the first wave of HCCP(Human Capital Corporate Panel) data produced by KRIVET(Korea Research Institute for Vocational Education and Training), this article finds that even though the skills attainead in corporate in Korea are mostly general(industry-specific), but the market failure in training appears rather small and is confined to the manufacturing industry. And the state intervention in corporate training works only at manufacturing industry, it does not work at new service industry. The results mean that in new service industry, it is difficult to find out the existence of market failure in training due to the positive externalities. Therefore Korea government should look thoroughly into the state intervention in training in new service industry.

  • PDF

Heart Failure Occurred during Endoscopic Transthoracic Sympathetic Cauterization -A case report- (흉강경하 교감신경절 소작술중 발생한 심부전 -증례 보고-)

  • Lee, Youn-Woo;Yoon, Duck-Mi;Ahn, Eun-Kyoung;Seouk, Mi-Ja
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.235-238
    • /
    • 1996
  • Hyperhidrosis is the distressing condition of abnormal sweating which affects the palm, sole and axillary region. Transthoracic endoscopic sympathectomy is recommended as the treatment of choice for hyperhidrosis, especially when the upper limbs are affected. We experienced a case of accidental cauterization of right azygos vein in a healthy 23 year old male during endoscopic transthoracic sympathectomy. We changed the single lumen endotracheal tube to a double lumen tube which made it easier to perform the explo-thoracotomy and bleeder ligation under one lung ventilation. Crystalloid and colloid solutions, and packed RBC were loaded during explo-thoracotomy. Monitoring showed the signs indicating pulmonary edema. Pulmonary arterial catheterization revealed global heart failure. The patient was transfered to ICU for intensive management for heart failure. On the 4th postoperative day, pulmonary edema and heart failure were cured; and the patient was extubated. But in the evening of the same day ST-segment elevation and Q-wave were noted on ECG monitoring. On the 13th postoperative day coronary angiography was performed. This revealed left apex focal hypokinesia, patent coronary artery and accidental right coronary spasm, treated by vasodilator. On the 14 day, after surgery, he was discharged to return to work.

  • PDF

Development of a Lifetime Test Bench for Robot Reducers for Fault Diagnosis and Failure Prognostics (고장 진단 및 예지가 가능한 로봇용 감속기 내구성능평가 장치 개발)

  • Shin, Ju Seong;Kim, Ju Hyun;Kim, Jong Geol;Jin, Maolin
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study presents the development of a lifetime test bench for the strain wave reducer which is a precision gear reducer of the robot to realize fault diagnosis and failure prognostics. To this end, the lifetime test bench was designed to detect the vertical forward/reverse direction rotation load. Through the lifetime test bench, it is possible to apply the same load spectrum from robot working scenarios. We developed a data integration gateway for fault data collection. Through the development of dedicated software for fault diagnosis and failure prognostics, these data from vibration, noise and temperature sensors were collected and analyzed along with the operation of the lifetime evaluation.

Experimental and numerical study on the collapse failure of long-span transmission tower-line systems subjected to extremely severe earthquakes

  • Tian, Li;Fu, Zhaoyang;Pan, Haiyang;Ma, Ruisheng;Liu, Yuping
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.513-522
    • /
    • 2019
  • A long-span transmission tower-line system is indispensable for long-distance electricity transmission across a large river or valley; hence, the failure of this system, especially the collapse of the supporting towers, has serious impacts on power grids. To ensure the safety and reliability of transmission systems, this study experimentally and numerically investigates the collapse failure of a 220 kV long-span transmission tower-line system subjected to severe earthquakes. A 1:20 scale model of a transmission tower-line system is constructed in this research, and shaking table tests are carried out. Furthermore, numerical studies are conducted in ABAQUS by using the Tian-Ma-Qu material model, the results of which are compared with the experimental findings. Good agreement is found between the experimental and numerical results, showing that the numerical simulation based on the Tian-Ma-Qu material model is able to predict the weak points and collapse process of the long-span transmission tower-line system. The failure of diagonal members at weak points constitutes the collapse-inducing factor, and the ultimate capacity and weakest segment vary with different seismic wave excitations. This research can further enrich the database for the seismic performance of long-span transmission tower-line systems.

Reliability Analysis of Caisson Type Breakwater using Load Surface (하중면을 이용한 케이슨식 방파제의 신뢰성해석)

  • Kim, Dong-Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.3
    • /
    • pp.209-215
    • /
    • 2009
  • A new load surface method for reliability of caisson type breakwater was proposed. Linear functions for horizontal wave force and uplift force were estimated by using water level and wave height then they were applied to the reliability analysis of breakwater using first order reliability method(FORM). In the numerical example, sliding and overturning failure probability of caisson type breakwater were analyzed by using load surface and they were compared with those by Monte Carlo simulation.

Development of an electronic starter using a half-wave rectifier for fluorescent lamps (반파정류를 이용한 형광램프용 전자식 스타터의 개발)

  • Lee, Dong-Ho;Song, Song-Bin;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2088-2090
    • /
    • 1998
  • A low-cost electronic starter is developed to decrease ignition failure significantly through successive starting trial and to prevent overheating at the end of fluorescent lamp life. Moreover, it has an additional feature of being capable of ignition at the recovered lamp voltage without any circuit correction. The developed electronic starter is consisted of four parts - a half wave rectifier circuit, a timer circuit, a switching circuit and a protection circuit. The protection circuit made up of a transistor and capacitors utilizing capacitive characteristics, carries out successive starting trial and end-of-life protection. Lamp ignition is completed within 0.5 seconds with taking advantage of a high preheating current from the half-wave rectifier circuit. Nevertheless, its performance is proved to be very excellent through a standard switching endurance test.

  • PDF

The Shock and Fracture Analysis of Ship Structure Subject to Underwater Shock Loading (수중충격하중을 받는 선체구조의 충격 및 파손 해석)

  • Kie-Tae Chung;Kyung-Su Kim;Young-Bok Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.1
    • /
    • pp.118-131
    • /
    • 1995
  • The shock fracture analysis for the structures of navy vessels subject to underwater explosions or of high speed vessels frequently subject to impact loads has been carried out in two steps such as the global or macro analysis and the fine or micro analysis. In the macro analysis, Doubly Asymptotic Approximation(DAA) has been applied. The three main failure modes of structure members subject to strong shock loading are late time fracture mode such as plastic large deformation mainly due to dynamic plastic buckling, and the early time fracture mode such as tensile tearing failure or transverse shear failure. In this paper, the tensile tearing failure mode is numerically analyzed for the micro analysis by calculating the dynamic stress intensity factor $K_I(t)$, which shows the relation between stress wave and crack propagation on the longitudinal stiffener of the model. Especially, in calculating this factor, the numerical caustic method developed from shadow optical method of caustic well known as experimental method is used. The fully submerged vessel is adopted for the macro analysis at first, of which the longitudinal stiffener, subject to early shock pressure time history calculated in macro analysis, is adopted for the micro analysis.

  • PDF