• 제목/요약/키워드: Failure mode interaction

검색결과 62건 처리시간 0.021초

블록전단파괴 : State of the Arts (Block Shear Failure : State of the Arts)

  • 장선재;이우철;임남형;이진옥
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.75-78
    • /
    • 2008
  • Limit states of a tension member are the yielding of gross section, fracture of net section, and block shear failure. Block shear failure is very complicated than other limit state because of interaction of tension and shear failure. Block shear failure is studied continuously since the 1970s. However, failure model to estimate the strength of block shear failure provided in current design specifications is not reflective of the failure mode observed in the various experimental studies. Comparisons between the experimental results and design rules in various specifications about the block shear failure were conducted in this study. Also, the need for further studies of block shear failure were proposed.

  • PDF

Modeling of RC shear walls strengthened by FRP composites

  • Sakr, Mohammed A.;El-khoriby, Saher R.;Khalifa, Tarek M.;Nagib, Mohammed T.
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.407-417
    • /
    • 2017
  • RC shear walls are considered one of the main lateral resisting members in buildings. In recent years, FRP has been widely utilized in order to strengthen and retrofit concrete structures. A number of experimental studies used CFRP sheets as an external bracing system for retrofitting of RC shear walls. It has been found that the common mode of failure is the debonding of the CFRP-concrete adhesive material. In this study, behavior of RC shear wall was investigated with three different micro models. The analysis included 2D model using plane stress element, 3D model using shell element and 3D model using solid element. To allow for the debonding mode of failure, the adhesive layer was modeled using cohesive surface-to-surface interaction model at 3D analysis model and node-to-node interaction method using Cartesian elastic-plastic connector element at 2D analysis model. The FE model results are validated comparing the experimental results in the literature. It is shown that the proposed FE model can predict the modes of failure due to debonding of CFRP and behavior of CFRP strengthened RC shear wall reasonably well. Additionally, using 2D plane stress model, many parameters on the behavior of the cohesive surfaces are investigated such as fracture energy, interfacial shear stress, partial bonding, proposed CFRP anchor location and using different bracing of CFRP strips. Using two anchors near end of each diagonal CFRP strips delay the end debonding and increase the ductility for RC shear walls.

적층 IC 패키지의 고장모드 분류와 대책 (Failure Modes Classification and Countermeasures of Stacked IC Packages)

  • 송근호;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권4호
    • /
    • pp.347-355
    • /
    • 2016
  • Purpose: With the advance of miniaturization of electronic products, stacked packages of high density semiconductors are commonly used. Potential failure modes and mechanisms of stacked packages are identified. Methods: Failure modes and mechanisms of thin chip stacked packages are determined through the categorization and failure analysis: delamination, non-wet, crack, ESD, EMI and the process related damages. Results: Those failure modes are not easy to find and require excessive amount time and effort for analysis and subsequent improvement. Conclusion: In this study, a method of estimating the failure rate based on the strength measurement is suggested.

Probabilistic ultimate strength analysis of submarine pressure hulls

  • Cerik, Burak Can;Shin, Hyun-Kyoung;Cho, Sang-Rai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권1호
    • /
    • pp.101-115
    • /
    • 2013
  • This paper examines the application of structural reliability analysis to submarine pressure hulls to clarify the merits of probabilistic approach in respect thereof. Ultimate strength prediction methods which take the inelastic behavior of ring-stiffened cylindrical shells and hemi-spherical shells into account are reviewed. The modeling uncertainties in terms of bias and coefficient of variation for failure prediction methods in current design guidelines are defined by evaluating the compiled experimental data. A simple ultimate strength formulation for ring-stiffened cylinders taking into account the interaction between local and global failure modes and an ultimate strength formula for hemispherical shells which have better accuracy and reliability than current design codes are taken as basis for reliability analysis. The effects of randomness of geometrical and material properties on failure are assessed by a prelimnary study on reference models. By evaluation of sensitivity factors important variables are determined and comparesons are made with conclusions of previous reliability studies.

2D numerical study of the mechanical behaviour of non-persistent jointed rock masses under uniaxial and biaxial compression tests

  • Vaziri, Mojtaba Rabiei;Tavakoli, Hossein;Bahaaddini, Mojtaba
    • Geomechanics and Engineering
    • /
    • 제28권2호
    • /
    • pp.117-133
    • /
    • 2022
  • Determination of the mechanical behaviour of jointed rock masses has been a challenge for rock engineers for decades. This problem is more pronounced for non-persistent jointed rock masses due to complicated interaction of rock bridges on the overall behaviour. This paper aims to study the effect of a non-persistent joint set configuration on the mechanical behaviour of rock materials under both uniaxial and biaxial compression tests using a discrete element code. The numerical simulation of biaxial compressive strength of rock masses has been challenging in the past due to shortcomings of bonded particle models in reproducing the failure envelope of rock materials. This problem was resolved in this study by employing the flat-joint contact model. The validity of the numerical model was investigated through a comprehensive comparative study against physical uniaxial and biaxial compression experiments. Good agreement was found between numerical and experimental tests in terms of the recorded peak strength and the failure mode in both loading conditions. Studies on the effect of joint orientation on the failure mode showed that four zones of intact, transition to block rotation, block rotation and transition to intact failure occurs when the joint dip angle varies from 0° to 90°. It was found that the applied confining stress can significantly alter the range of these zones. It was observed that the minimum strength occurs at the joint dip angle of around 45 degrees under different confining stresses. It was also found that the joint orientation can alter the post peak behaviour and the lowest brittleness was observed at the block rotation zone.

직접전단시험모델에 의한 뿌리말뚝의 탄소성조인트 유한요소해석 (Elasto-plastic Joint Finite Element Analysis of Root-pile Using the Direct Shear Test Model)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제5권4호
    • /
    • pp.19-30
    • /
    • 2002
  • The stability of slope using root-pile like to the reinforcements is affected by the interaction behavior mechanism of soil-reinforcements. Through the studying on the interaction in joint of its, therefore, the control roles can be find out in installed slope. In study, the stress level ratio based on the insert angle of installed reinforcements in soil used to numerical analysis, which was results from the duty direct shear test in Lab. The maximum shear strain variation on the reinforcements was observed at insert angle, which was approximately similar to the calculated angle based on the equation proposed by the Jewell. The elasto-plastic joint model on the contact area of soil-reinforcements was presumed, the reinforced soil assumed non-linear elastic model and the reinforcements supposed elastic model, respectively. The finite element analysis of assumed models was performed. The shear strain variation of non-reinforced state obtained by the FEM analysis including elasto-plastic joint elements were shown the rationality of general limit equilibrium analysis for the slope failure mode on driving zone and resistance zone, which based on the stress level step according to failure ratio. Through the variation of shear strain for the variation of inserting angle of reinforcements, the different mechanism on the bending and the shear resistance of reinforcements was shown fair possibility.

인장시험(引張試驗)에 의한 보강토(補强土)의 거동결정(擧動決定) (Soil-Reinforcement Interaction Determined by Extension Test)

  • 김운영
    • 대한토목학회논문집
    • /
    • 제8권1호
    • /
    • pp.33-40
    • /
    • 1988
  • 흙과 보강재 사이의 거동을 측정하는 수단으로서 hollow cylinder type의 샘플 내에 보강재를 인장방향으로 삽입하여 주위압력을 일정하게 유지한 가운데 축력(軸力)을 감소시키는 소위 삼축인장시험을 실시하였다. 인장특성(引張特性)(extensibility)이 상이(相異)한 3종류의 보강재를 사용한 결과 파괴변형율(failure strain), 최대강도후의 응력강소(loss of post-peak strength), 변형모양(deformation mode) 등이 보강재에 따라 각각 독특하였고, 파괴의 양상은 breakage 또는 pull-out 이 발생하였으며, 보강재단(補强材端)의 고정여부에 따라 보강효과가 영향을 받음이 확인되었다. 따라서 보강토해석 및 설계시 흙 및 보강재 자체의 강도(强度)와 더불어 보강재의 인장특성(引張特性)과 경계조건(境界條件)이 매우 중요한 고려요소임을 알 수 있었다.

  • PDF

제주 HVDC No. 2의 극간 상호작용 경험과 분석: 무정전 전력 송전을 위한 실용적 해결방안 (Experience and Analysis of Pole Interaction for Jeju HVDC No. 2: Practical Solution for Non-Interruptible Power Transfer)

  • 김희진;김찬기;박창환
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.459-468
    • /
    • 2020
  • The pole interaction of the line-commutated converter high-voltage direct current (HVDC) is analyzed, and a practical solution that uses a surge arrester is proposed. Jeju HVDC No. 2 is a double-monopole HVDC link that has a rated power capacity of 2 × 200 MW and was commissioned in 2012. During normal operation, Jeju HVDC No. 2 is operated in the bipolar mode to minimize the loss caused by the dedicated metallic return. However, when one pole of the inverter valve is bypassed, a commutation failure can occur in the other pole. This phenomenon is called pole interaction in this work. This pole interaction interrupts the HVDC power transfer for almost 2 s and may affect the stability of the power system. This research proposes the installation of a surge arrester at the inverter neutral, which can be an effective and practical solution for pole interaction. The HVDC system is analyzed, and the residual voltage of the surge arrester is determined. Detailed simulation using PSCAD/EMTDC demonstrates that the proposed method eliminates the pole interaction of the bipolar-operated HVDC.

Enhanced macro element for nonlinear analysis of masonry infilled RC frame structures

  • Mebarek Khelfi;Fouad Kehila
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.177-186
    • /
    • 2023
  • Reinforced concrete frames with a masonry infill panel is a structural typology frequently used worldwide. In seismic cases, the interaction between the masonry infill and the RC frames constitutes one of the most complex subjects in earthquake engineering. In this work, an enhancement of an existing numerical model is proposed to improve the estimation of lateral strength and stiffness of masonry-infilled frame structures and predict their probable failure modes. The proposed improvement is based on attributing corrective coefficients to the shear strength of each diagonal shear spring of the macro element, which simulates the masonry infill. The improved numerical model is validated by comparing the results with those of the original numerical model and with experimental results available in the literature. The enhanced macro element model can be used as a powerful, accessible tool for assessing the capacity and stiffness of masonry-infilled frame structures and predicting their probable failure modes.

실패모드에 근거한 서비스 신뢰도 평가모델 (Evaluating Service Reliability focused on Failure Modes)

  • 오형술
    • 벤처창업연구
    • /
    • 제7권3호
    • /
    • pp.133-141
    • /
    • 2012
  • 글로벌 경쟁 상황에 처한 현대의 모든 기업들은 고객의 니즈를 충족시키고, 이를 통한 경쟁력을 강화하기 위한 방안으로서 서비스를 이해하기 시작하면서 서비스에 대한 관심이 날로 증가하고 있다. 기업들이 제공하는 제품이나 서비스의 가치는 주로 고객과 서비스 제공자 간의 관계에서 형성되는 만족도의 정도로 정의되는 서비스 신뢰도에 의해 크게 좌우된다. 본 연구에서는, 유형의 제품이나 시스템의 실패 유형과 영향을 평가하는데 널리 사용되는 FMEA를 서비스의 신뢰도 평가에 적용하였다. 이를 위해, 서비스의 설계와 서비스 기능과 실패 간의 관계를 용이하게 표현할 수 있는 사건중심 프로세스 모델을 이용하였다. 본 연구의 목적은 서비스 프로세스 관점에서의 서비스 신뢰도를 평가하는 방법을 제시하는 것으로서, 이를 위해 fuzzy FMEA와 grey 이론을 이용하였다. 제안된 방법은 자동차정비 프로세스 사례에 적용하여 평가하였다.

  • PDF