• Title/Summary/Keyword: Failure behaviour

Search Result 514, Processing Time 0.028 seconds

Confinement models for high strength short square and rectangular concrete-filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Wang, Ziwen;Patel, Vipul
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.937-974
    • /
    • 2016
  • While extensive efforts have been made in the past to develop finite element models (FEMs) for concrete-filled steel tubular columns (CFSTCs), these models may not be suitable to be used in some cases, especially in view of the utilisation of high strength steel and high strength concrete. A method is presented herein to predict the complete stress-strain curve of concrete subjected to tri-axial compressive stresses caused by axial load coupled with lateral pressure due to the confinement action in square and rectangular CFSTCs with normal and high strength materials. To evaluate the lateral pressure exerted on the concrete in square and rectangular shaped columns, an accurately developed FEM which incorporates the effects of initial local imperfections and residual stresses using the commercial program ABAQUS is adopted. Subsequently, an extensive parametric study is conducted herein to propose an empirical equation for the maximum average lateral pressure, which depends on the material and geometric properties of the columns. The analysis parameters include the concrete compressive strength ($f^{\prime}_c=20-110N/mm^2$), steel yield strength ($f_y=220-850N/mm^2$), width-to-thickness (B/t) ratios in the range of 15-52, as well as the length-to-width (L/B) ratios in the range of 2-4. The predictions of the behaviour, ultimate axial strengths, and failure modes are compared with the available experimental results to verify the accuracy of the models developed. Furthermore, a design model is proposed for short square and rectangular CFSTCs. Additionally, comparisons with the prediction of axial load capacity by using the proposed design model, Australian Standard and Eurocode 4 code provisions for box composite columns are carried out.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Early dropout predictive factors in obesity treatment

  • Michelini, Ilaria;Falchi, Anna Giulia;Muggia, Chiara;Grecchi, Ilaria;Montagna, Elisabetta;De Silvestri, Annalisa;Tinelli, Carmine
    • Nutrition Research and Practice
    • /
    • v.8 no.1
    • /
    • pp.94-102
    • /
    • 2014
  • Diet attrition and failure of long term treatment are very frequent in obese patients. This study aimed to identify pre-treatment variables determining dropout and to customise the characteristics of those most likely to abandon the program before treatment, thus making it possible to modify the therapy to increase compliance. A total of 146 outpatients were consecutively enrolled; 73 patients followed a prescriptive diet while 73 followed a novel brief group Cognitive Behavioural Treatment (CBT) in addition to prescriptive diet. The two interventions lasted for six months. Anthropometric, demographic, psychological parameters and feeding behaviour were assessed, the last two with the Italian instrument VCAO Ansisa; than, a semi-structured interview was performed on motivation to lose weight. To identify the baseline dropout risk factors among these parameters, univariate and multivariate logistic models were used. Comparison of the results in the two different treatments showed a higher attrition rate in CBT group, despite no statistically significant difference between the two treatment arms (P = 0.127). Dropout patients did not differ significantly from those who did not dropout with regards to sex, age, Body Mass Index (BMI), history of cycling, education, work and marriage. Regardless of weight loss, the most important factor that determines the dropout appears to be a high level of stress revealed by General Health Questionnaire-28 items (GHQ-28) score within VCAO test. The identification of hindering factors during the assessment is fundamental to reduce the dropout risk. For subjects at risk, it would be useful to dedicate a stress management program before beginning a dietary restriction.

Development of the Piecewisely-integrated Composite Bumper Beam Based on the IIHS Crash Analysis (IIHS 충격해석에 근거한 구간 조합 복합재료 범퍼 빔 개발)

  • Jeong, Chan-Hee;Ham, Seok-Wu;Kim, Gyeong-Seok;Cheon, Seong S.
    • Composites Research
    • /
    • v.31 no.1
    • /
    • pp.37-41
    • /
    • 2018
  • The aim of the current work is to characterise a piecewisely-integrated composite bumper beam based on the IIHS bumper crash protocol. IIHS bumper crash FE analysis for an aluminium type bumper beam was carried out to get the information about the dominant loading types at several regions in the bumper beam during crash. In the meantime, robust stacking sequences against tension and compression have been searched for using FE analysis of a coupon type model. After determining most effective stacking sequences for tension and compression, three-point bending simulation was preliminarily carried out to investigate the combination performance of them. Finally, IIHS bumper crash FE analysis for the piecewisely-integrated composite bumper beam, which consisted of the combination of tension effective stacking sequence and compression efficacious stacking sequence, was conducted and the result was compared with other types of composite bumper beams. It was found that the newly suggested piecewisely-integrated composite bumper beam showed superior crashworthy behaviour to those of uni-modal stacking sequence composite bumper beams.

Studies on the Development of Bearing Capacity Reinforcement for the Foundation of Soil (기초지반의 지지력보강공법에 관한 연구)

  • 유동환;최예환;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-49
    • /
    • 1988
  • This paper presented as follows results of laboratory model tests with various shaped footings on soil bed reinforced with the strips on the base of behaviour of soil structure according to the loads and triaxial test results reinforced with geotextiles. Their parameters studied were the effects on the bearing capacity of a footing of the first layer of reinforcement, horizontal and vertical spacing of layers, number of layers, tensile strength of reinforcement and iclination load to the vertical 1.Depending on the strip arrangement, ultimate bearing capacity values could be more improved than urreinforced soil and the failure of soil was that the soil structure was transfered from the macrospace to microspase and its arrangement, from edge to edge to face to face. 2.The reinforcement was produced the reinforcing effects due to controlling the value of factor of one and permeable reinforcement was never a barrier of drainage condition. 3.Strength ratio was decreased as a linear shape according to increment of saturation degree of soil used even though at the lower strength ratio, the value of M-factor was rot influenced on the strength ratio but impermeable reinforcement decreased the strength of bearing capacity. 4.Ultimate bearing capacity under the plane-strain condition was appeared a little larger than triaxial or the other theoretical formulars and the circular footing more effective. 5.The maximum reinforcing effects were obtained at U I B=o.5, B / B=3 and N=3, when over that limit only acting as a anchor, and same strength of fabric appeared larger reinforcing effects compared to the thinner one. 6.As the LDR increased, more and more BCR occurred and there was appeared a block action below Z / B=O.5, but over the value, decrement of BCR was shown linear relation, and no effects above one. 7.The coefficient of the inclination was shown of minimum at the three layers of fabrics, but the value of H / B related to the ultimate load was decreased as increment of inclination degree, even though over the value of 4.5 there wasn't expected to the reinforcing effects As a consequence of the effects on load inclination, the degree of inclination of 15 per cent was decreased the bearing capacity of 70 per cent but irnproved the effects of 45 per cent through the insertion of geotextile.

  • PDF

The Economics of GHP and EHP and the Countermeasures to Alleviate Winter Electricity Peaks (GHP와 EHP의 경제성 및 동계 전력피크 대응방안)

  • Yun, Won-Cheol;Sonn, Yang-Hoon
    • Environmental and Resource Economics Review
    • /
    • v.20 no.2
    • /
    • pp.381-398
    • /
    • 2011
  • Recently, electricity peaks have frequently occurred in winter, and the concerns about failure in power supply are soaring. One of reasons is due to the increase in industrial demand with economic recovery, and the increases in household and commercial demand with unusual cold waves are spotted as a primary cause. Especially, the diffusion of electricity heat pumps (EHP) has led to the rapid increase in commercial electricity demand. The EHP diffusion is mainly associated with low electricity tariff and cheaper heating and cooling costs compared to those of gas-engine heat pumps (GHP). The problem is that distorted electricity tariff and herd behaviour toward heating and cooling devices could bring about nation-wide inefficiencies in resource allocation. The key countermeasures are as follows. The electricity tariff should be readjusted to a realistic level. The tariff scheme should be so modified that consumers rationally respond to the tariff. In addition, one should find ways to effectively manage electricity demand.

  • PDF

A Comparative Study of Printed versus Digital Index and Abstract Users' Behaviour Patterns (인쇄형 색인초록과 전자형 색인초록의 이용행태에 관한 비교연구)

  • Hoang Gum-Sook
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.32 no.1
    • /
    • pp.169-187
    • /
    • 1998
  • The primary purpose of this study is to compare printed index and abstract user's behaviours with digital index and abstract user's behaviours, and to verify of structured characteristics of a printed index and abstract. The major findings are as follows: (1) When the research topic is not specified enough, users tend to rely on printed indexes and abstracts search, whereas they utilize digital form in order to do retrospective search in the stage of research when the topic is determined. (2) Printed index and abstract users are expecting small number of literatures in search, whereas digital index and abstract users are expecting large number of literatures to be found The former are more satisfied with the result of search than the latter. (3) Digital index and abstract users experience more search failure than printed Index and abstract users. When they fail to find wanted materials, both users turn to the other form of indexes and abstracts. (4) Printed index and abstract users shows significantly less knowledge on online searching than digital index and abstract users.

  • PDF

An Experimental Study on Bending Behaviour of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 휨거동에 관한 실험적 연구)

  • Shin, Hyun Seop;Lee, Chin Hyung;Park, Ki Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.68-77
    • /
    • 2012
  • The joint of existing steel grid composite deck is composed of lap splice of reinforcing bar with end hooks and field-placed concrete. In this study, bending tests of deck joint composed of concrete shear key and high tension bolts are carried out for the design variable, concrete shear key strengthened with steel plate or not, and test results are compared with flexural performance of the existing deck joint. Test results showed that the mechanical deck joint has about 30% ~ 60% more ultimate bending strength than the existing joint. According to analysis results of moment-curvature relationship, the initial bending stiffness of the existing deck joint is some higher than that of mechanical joint. But, after crack failure the structural performance of the existing deck joint is rapidly reduced. Furthermore, the deck joint with the strengthened shear key with steel plate has more bending moment capacity than the deck joint without strengthening. And strengthening of shear key has positive influence on the increase of bending stiffness.

Characteristics of Stress-Strain for Pocheon stone sludge (포천석분의 응력-변형률 거동특성)

  • Kim, Chan-Kee;Bak, Gueon-Jun;Cho, Won-Beom;Lee, Jong-Cheon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.55-64
    • /
    • 2013
  • In this study, a series of the isotropic compression-expansion tests and the Undrained triaxial tests were performed on low-plastic silt of Pocheon stone sludge. Using the tests results the characteristic of the parameters of Lade's single hardening constitutive model were investigated. We also observed that predicted values from the Lade's single hardening constitutive model were well consistent with the observed data. In experimental results the deviator stress showed the work hardening behaviour after reaching its yield stress. Therefore practically useful failure criterion for low-plastic silt were required. The stress-strain behavior predicted by 11 soil parameters are compared with the results obtained 9 parameters by correlation between h and ${\eta}_1$ and constant ${\alpha}$. They are poor matched each other.

Experimental Studies of Characteristics of Strength and Deformation Behaviour of Frozen and Cyclic Frozen-thawed Clayey Soils (동결 및 동결-융해작용을 받는 점성토의 강도와 그의 변형거동)

  • 유능환;유영선;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.2
    • /
    • pp.112-119
    • /
    • 1991
  • Some experiments were carried out to investigate the effects of freezing and thawing on the strength and strain characteristics of alluvial silty clay under the different temperatures, loading and moisture conditions. The results were as follows; 1. The soil used was proved to be consisted of silty clay with honey-combed structure, and showed higher dilatancy, frost activity and lower stability in natural state. 2. Soil treated with freezing and thawing cycles showed lower compressive strength compared with the non treated, The strength decreased with incement of freezing and thawing cycles. It's shapes of stress-strain curves were flat and did not formulate a peak while the peak strength of higher moisture content soil decreased with the increment of moisture content. It's decrement ratio was most distinctly shown at the first one cycle of freezing and thawing. 3. The cohesion decreased due to freezing and thawing cycles but internal frcition angle was not changed. 4. The liquid limit decreased with increment of freezing and thawing cycles, and became almost constant after three cycles of freezing and thawing. 5. The strength under simple loading at failure mode was appeared to be higher compared with the cyclic loading after freezing and thawing but initial moisture content effect was not observed. 6. Ice lense was not observed within 50% of ice content ratio but observed over 100%. The higher the ice content ratio, the higher the peak strength. As a matter of fact, it seems that an optimum ice content ratio exists for plastic mode and the least compressive strength.

  • PDF