• Title/Summary/Keyword: Failure Transition

Search Result 186, Processing Time 0.022 seconds

A Study for Characterization on Shallow Behavior of Soil Slope by Flume Experiments (토조실험 장치를 이용한 토사비탈면 표층거동 특성 연구)

  • Suk, Jae-wook;Park, Sung-Yong;Na, Geon-ha;Kang, Hyo-Sub
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.489-499
    • /
    • 2018
  • A flume experiments was used to study the characteristics of the surface displacements and volumetric water contents (VWC) during torrential rain. The surface displacement and VWC of the granite weathered soil were measured for rainfall intensity (100, 200 mm/hr) and initial ground condition (VWC 7, 14, 26%). The test processes were also recorded by video cameras. According to the test results, The shallow failure is classified into three types: retrogressive failure, progressive failure and defined failure. In the case of retrogressive failure and progressive failure, relatively large damage could occur due to the feature that soil is deposited to the bottom of the slope. the shallow failure occurred when the VWC reached a certain value regardless of the initial soil condition. It was found that the shallow failure can be predicted through the increase patton of the VWC under the condition of the ground dry condition (VWC 7%) and the natural condition (VWC 14%). For high rainfall intensity, progressive failure predominated, and rainfall intensity above a certain level did not affect wetting front transition.

Effect mechanism of unfrozen water on the frozen soil-structure interface during the freezing-thawing process

  • Tang, Liyun;Du, Yang;Liu, Lang;Jin, Long;Yang, Liujun;Li, Guoyu
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.245-254
    • /
    • 2020
  • The interaction between the frozen soil and building structures deteriorates with the increasing temperature. A nuclear magnetic resonance (NMR) stratification test was conducted with respect to the unfrozen water content on the interface and a shear test was conducted on the frozen soil-structure interface to explore the shear characteristics of the frozen soil-structure interface and its failure mechanism during the thawing process. The test results showed that the unfrozen water at the interface during the thawing process can be clearly distributed in three stages, i.e., freezing, phase transition, and thawing, and that the shear strength of the interface decreases as the unfrozen water content increases. The internal friction angle and cohesive force display a change law of "as one falls, the other rises," and the minimum internal friction angle and maximum cohesive force can be observed at -1℃. In addition, the change characteristics of the interface strength parameters during the freezing process were compared, and the differences between the interface shear characteristics and failure mechanisms during the frozen soil-structure interface freezing-thawing process were discussed. The shear strength parameters of the interface was subjected to different changes during the freezing-thawing process because of the different interaction mechanisms of the molecular structures of ice and water in case of the ice-water phase transition of the test sample during the freezing-thawing process.

Cancer Stem Cells in Head and Neck Squamous Cell Carcinoma: A Review

  • Satpute, Pranali Shirish;Hazarey, Vinay;Ahmed, Riyaz;Yadav, Lalita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5579-5587
    • /
    • 2013
  • Research indicates that a small population of cancer cells is highly tumorigenic, endowed with the capacity for self-renewal, and has the ability to differentiate into cells that constitute the bulk of tumors. These cells are considered the "drivers" of the tumorigenic process in some tumor types, and have been named cancer stem cells (CSC). Epithelial-mesenchymal transition (EMT) appears to be involved in the process leading to the acquisition of stemness by epithelial tumor cells. Through this process, cells acquire an invasive phenotype that may contribute to tumor recurrence and metastasis. CSC have been identified in human head and neck squamous cell carcinomas (HNSCC) using markers such as CD133 and CD44 expression, and aldehyde dehydrogenase (ALDH) activity. Head and neck cancer stem cells reside primarily in perivascular niches in the invasive fronts where endothelial-cell initiated events contribute to their survival and function. Clinically, CSC enrichment has been shown to be enhanced in recurrent disease, treatment failure and metastasis. CSC represent a novel target of study given their slow growth and innate mechanisms conferring treatment resistance. Further understanding of their unique phenotype may reveal potential molecular targets to improve therapeutic and survival outcomes in patients with HNSCC. Here, we discuss the state-of-the-knowledge on the pathobiology of cancer stem cells, with a focus on the impact of these cells on head and neck tumor progression, metastasis and recurrence due to treatment failure.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Identifying Security Requirement using Reusable State Transition Diagram at Security Threat Location (보안 위협위치에서 재사용 가능한 상태전이도를 이용한 보안요구사항 식별)

  • Seo Seong-Chae;You Jin-Ho;Kim Young-Dae;Kim Byung-Ki
    • The KIPS Transactions:PartD
    • /
    • v.13D no.1 s.104
    • /
    • pp.67-74
    • /
    • 2006
  • The security requirements identification in the software development has received some attention recently. However, previous methods do not provide clear method and process of security requirements identification. We propose a process that software developers can build application specific security requirements from state transition diagrams at the security threat location. The proposed process consists of building model and identifying application specific security requirements. The state transition diagram is constructed through subprocesses i) the identification of security threat locations using security failure data based on the point that attackers exploit software vulnerabilities and attack system assets, ii) the construction of a state transition diagram which is usable to protect, mitigate, and remove vulnerabilities of security threat locations. The identification Process of application specific security requirements consist of i) the analysis of the functional requirements of the software, which are decomposed into a DFD(Data Flow Diagram; the identification of the security threat location; and the appliance of the corresponding state transition diagram into the security threat locations, ii) the construction of the application specific state transition diagram, iii) the construction of security requirements based on the rule of the identification of security requirements. The proposed method is helpful to identify the security requirements easily at an early phase of software development.

An Experimental Study on the Failure of a Novel Composite Sandwich Structure (새로운 형상의 복합재 샌드위치 체결부 구조의 파손거동 연구)

  • Kwak, Byeong-Su;Kim, Hong-Il;Dong, Seung-Jin;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • The failure of composite sandwich structures with thickness and material variation was studied. The main body of the structure is sandwich plate made of the carbon composite face and Aluminum honeycomb core. It is connected with composite laminated flange without core through transition region of tapered sandwich panel with foam core. Tension and compression tests were conducted for the total of 6 panels, 3 for each. Test results showed that the panels under compression are vulnerable to the face failure along the material discontinuity line between two different cores. However the failure load of which panel does not show such failure can carry 16% more load and fails in honeycomb core and face debonding. For the tensile load, the extensive delamination failure was observed at the corner radius which connects the panel and the flange. The average failure load for compression is about 7 times the tensile failure load. Accordingly, these sandwich structures should be applied to the components that endure the compressive loadings.

Construction Of Uninterruptible Power System by Reliable Incoming Power Method (신뢰도 높은 수전방식에 의한 무(無)정전 전원설비 구축방안)

  • Choi, Jin-Sung;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.367-371
    • /
    • 2007
  • Large capacity UPS and emergency generators are being installed and operated at the specific target of important electric facilities that need uninterruptible power supply by the method of countermeasure against power failure for the less reliable incoming power method. Recently, CTTS (Closed Transition Transfer Switch) is being used as uninterruptible power transfer switch at the Common sources of electricity, generator and multiple generators. In this paper, construction plans for uninterruptible power supply system has been suggested in which CTTS has been applied to the secondary of incoming power generator for reliable common dual system method. By briefing the construction of incoming power facilities, large capacity UPS, emergency generator installation space and investment saving effects can be achieved.

  • PDF

Task-Level Dynamic Voltage Scaling for Embedded System Design: Recent Theoretical Results

  • Kim, Tae-Whan
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.3
    • /
    • pp.189-206
    • /
    • 2010
  • It is generally accepted that dynamic voltage scaling (DVS) is one of the most effective techniques of energy minimization for real-time applications in embedded system design. The effectiveness comes from the fact that the amount of energy consumption is quadractically proportional to the voltage applied to the processor. The penalty is the execution delay, which is linearly and inversely proportional to the voltage. According to the granularity of tasks to which voltage scaling is applied, the DVS problem is divided into two subproblems: inter-task DVS problem, in which the determination of the voltage is carried out on a task-by-task basis and the voltage assigned to the task is unchanged during the whole execution of the task, and intra-task DVS problem, in which the operating voltage of a task is dynamically adjusted according to the execution behavior to reflect the changes of the required number of cycles to finish the task before the deadline. Frequent voltage transitions may cause an adverse effect on energy minimization due to the increase of the overhead of transition time and energy. In addition, DVS needs to be carefully applied so that the dynamically varying chip temperature should not exceed a certain threshold because a drastic increase of chip temperature is highly likely to cause system function failure. This paper reviews representative works on the theoretical solutions to DVS problems regarding inter-task DVS, intra-task DVS, voltage transition, and thermal-aware DVS.

Effect of 2-Hydroxyethyl Acrylate for the Properties of Acrylic Pressure Sensitive Adhesives (2-Hydroxyethyl Acrylate가 아크릴계 점착제의 물성에 미치는 영향)

  • Jeong, Noh-Hee;Park, Young-Jun;Lee, Hyang-Woo;Nam, Ki-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.262-266
    • /
    • 2000
  • Acrylic pressure sensitive adhesives of n-butyl acrylate, 2-ethyl acrylate, methyl acrylate, vinyl acetate, acrylic acid, acrylonitrile and 2-hydroxyethyl acrylate were synthesized and basic physical properties of pressure sensitive adhesives with increasing the contents of 2-hydroxyethyl acrylate were investigated. 2-Hydroxyethyl acrylates effects on glass transition temperature, viscosity, hardening time and peel strength. Glass transition temperature(Tg) decreased with increasing the contents of 2-hydroxyethyl acrylate. Viscosity and hardening time were increased with increasing the contents of 2-hydroxyethyl acrylate. On the other hands, peel strength increased with increasing the contents of 2-hydroxyethyl acrylate up to 6 wt% and the decreased at further higher contents of 2-hydroxyethyl acrylate. In peel test, interfacial failure was occured in 8 wt% and 10wt%.

Uniaxial tensile test integrated design considering mould-fixture for UHPC

  • Zhang, Xiaochen;Shen, Chao;Zhang, Xuesen;Wu, Xiangguo;Faqiang, Qiu;Mitobaba, Josue G.
    • Advances in Computational Design
    • /
    • v.7 no.4
    • /
    • pp.281-295
    • /
    • 2022
  • Tensile property is one of the excellent properties of ultra-high performance concrete (UHPC), and uniaxial tensile test is an important and challenging mechanical performance test of UHPC. Traditional uniaxial tensile tests of concrete materials have inherent defects such as initial eccentricity, which often lead to cracks and failure in non-test zone, and affect the testing accuracy of tensile properties of materials. In this paper, an original integrated design scheme of mould and end fixture is proposed, which achieves seamless matching between the tension end of specimen and the test fixture, and minimizes the cumulative eccentricity caused by the difference in the matching between the tension end of specimen and the local stress concentration at the end. The stress analysis and optimization design are carried out by finite element method. The curve transition in the end of specimen is preferred compared to straight line transition. The rationality of the new integrated design is verified by uniaxial tensile test of strain hardening UHPC, in which the whole stress-strain curve was measured, including the elastic behavior before cracking,strain hardening behavior after cracking and strain softening behavior.