• Title/Summary/Keyword: Failure Code

Search Result 639, Processing Time 0.022 seconds

Confinement models for high strength short square and rectangular concrete-filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Wang, Ziwen;Patel, Vipul
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.937-974
    • /
    • 2016
  • While extensive efforts have been made in the past to develop finite element models (FEMs) for concrete-filled steel tubular columns (CFSTCs), these models may not be suitable to be used in some cases, especially in view of the utilisation of high strength steel and high strength concrete. A method is presented herein to predict the complete stress-strain curve of concrete subjected to tri-axial compressive stresses caused by axial load coupled with lateral pressure due to the confinement action in square and rectangular CFSTCs with normal and high strength materials. To evaluate the lateral pressure exerted on the concrete in square and rectangular shaped columns, an accurately developed FEM which incorporates the effects of initial local imperfections and residual stresses using the commercial program ABAQUS is adopted. Subsequently, an extensive parametric study is conducted herein to propose an empirical equation for the maximum average lateral pressure, which depends on the material and geometric properties of the columns. The analysis parameters include the concrete compressive strength ($f^{\prime}_c=20-110N/mm^2$), steel yield strength ($f_y=220-850N/mm^2$), width-to-thickness (B/t) ratios in the range of 15-52, as well as the length-to-width (L/B) ratios in the range of 2-4. The predictions of the behaviour, ultimate axial strengths, and failure modes are compared with the available experimental results to verify the accuracy of the models developed. Furthermore, a design model is proposed for short square and rectangular CFSTCs. Additionally, comparisons with the prediction of axial load capacity by using the proposed design model, Australian Standard and Eurocode 4 code provisions for box composite columns are carried out.

Study on Axial Crushing Behaviors of UD Kevlar/Epoxy with Different Trigger Models (트리거 모델에 따른 일방향 케블라/에폭시 복합재 튜브의 축방향 압괴 거동 연구)

  • Kim, Hyung-Uk;Kim, Jung-Seok;Jung, Hyun-Seung;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.28-34
    • /
    • 2010
  • In this paper, in order to develop a realistic trigger model for a unidirectional Kevlar/Epoxy tube, the numerical model has been established and then verified by comparison with the experimental result. To achieve this goal, four different trigger models were candidated and evaluated using the commercial explicit FE code LS-DYNA. In the finite element analysis, the 2D shell element and Chang-Chang failure criterion was used. Mechanical material properties for the model were obtained by material testing in advance. The numerical results were compared with quasi-static test results under axial compressive loading at 10mm/min. The load-crushed displacement curves were very close to the experiments and SEA (specific energy absorption) showed a good agreement with experimental one within less than 5%.

Performance Analysis of Access Channel Decoder Implemeted for CDMA2000 1X Smart Antenna Base Station (CDMA2000 1X 스마트 안테나 기지국용으로 구현된 액세스 채널 복조기의 성능 분석)

  • 김성도;현승헌;최승원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.147-156
    • /
    • 2004
  • This paper presents an implementation and performance analysis of an access channel decoder which exploits a diversity gain due to the independent magnitude of received signals energy at each of antenna elements of a smart antenna BTS (Base-station Transceiver Subsystem) operating in CDMA2000 1X signal environment. Proposed access channel decoder consists of a searcher supporting 4 fingers, Walsh demodulator, and demodulator controller. They have been implemented with 5 of 1 million-gate FPGA's (Field Programmable Gate Array) Altera's APEX EP20K1000EBC652 and TMS320C6203 DSP (digital signal processing). The objective of the proposed access channel decoders is to enhance the data retrieval at co]1-site during the access period, for which the optimal weight vector of the smart antenna BTS is not available. Through experimental tests, we confirmed that the proposed access channel decoder exploitng the diversity technique outperforms the conventional one, which is based on a single antenna channel, in terms of detection probability of access probe, access channel failure probability, and $E_{b/}$ $N_{o}$ in Walsh demodulator.r.r.

Seismic Performance Evaluation of Hexagonal Blocks Infilled RC Frames (육각형 블록을 이용한 채움벽 RC 골조의 채움벽 내진성능평가)

  • Chang, Kug Kwan;Seo, Dae Won;Ko, Tae Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.116-124
    • /
    • 2011
  • RC frames with unreinforced masonry infiledl walls are common in worldwide. Since infilled walls are normally considered as non-structural elements, their presence is often ignored by engineers. In this study, to improve the seismic performance of masonry walls, hexagonal block was developed and the influence of masonry infilled wall on the seismic performance of reinforced concrete(RC) frames that were designed in accordance with current code provisions without the consideration of earthquake loadings are investigated. Two 1/2 scale, single story, single bay, frame specimens were tested. The parameters investigated included that the strength of infilled wallls with respect to that of the lateral load history. The experimental results indicate that infilled walls can significantly improve the lateral stiffness and strength of RC frames. The lateral loads developed by the infilled frame specimen is higher than that of the bare frame. It also indicates that infilled walls can be potentially used to improve the performance of existing nonductile frames. For this purpose. methods should be developed to avoid irreparable damage and catastrophic failure.

Reliability Analysis Model for Deflection Limit State of Deteriorated Steel Girder Bridges (처짐한계상태함수를 이용한 노후 강거더 교량의 신뢰성해석 모델 구축)

  • Eom, Jun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.47-53
    • /
    • 2014
  • The paper investigates the limit state of deflection for short and medium span steel girder bridges. Deflection depends on stiffness of steel girders and integrity of the reinforced concrete slab (composite action). Load and resistance parameters are treated as random variables. A probabilistic model is developed for prediction of the deflection. The structural performance can be affected by deterioration of components, in particular corrosion of steel girders. In addition, the creep of concrete can greatly influence the deflection of composite structures. Therefore, the statistical models for creep and corrosion of structural steel are incorporated in the model. Structures designed according to the AASHTO LRFD Code are considered. Load and resistance models are developed to account for time-variability of the parameters. Monte Carlo simulations are used to estimate the deflections and probabilities of serviceability failure. Different span lengths and girder spacing are considered for structures designed as moment-controlled and deflection-controlled. A summary of obtained results is presented.

Design and Implementation of USN Middleware using DTD GenerationTechnique (DTD 자동 생성 기법을 이용한 USN 미들웨어 설계 및 구현)

  • Nam, Si-Byung;Kwon, Ki-Hyeon;Yu, Myung-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.41-50
    • /
    • 2012
  • In the monitoring system based on web service application, it is faced with the problems like code reproduction, difficult scalability and error recovery derived from the frequent change of data structure. So we propose a technique of monitoring system by DTD(Document Type Definition) automatic generation. This technique is to use dynamic server-side script to cope with the change of sensor data structure, generate the DTD dynamically. An it also adapt the AJAX(Asynchronous JavaScript and XML) for XML data parsing, it can support mass data transmission and exception processing for data loss and damage. This technique shows the result of recovery time is decreased about 44.8ms in case of temporary data failure by comparing to the conventional XML method.

ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

  • Jain, Vikas;Nayak, A.K.;Dhiman, M.;Kulkarni, P.P.;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.625-636
    • /
    • 2013
  • Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor 'AHWR' is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI), Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

Study on the Axial Crushing Behaviors of UD Kevlar/Epoxy and Carbon-Kevlar/Epoxy Composite Tubes (단방향 케블라/에폭시, 탄소-케블라/에폭시 복합재 튜브의 축방향 압괴 거동에 대한 연구)

  • Kim, Hyung-Uk;Kim, Jung-Seok;Jung, Hyun-Seung;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.271-277
    • /
    • 2010
  • In this paper, a numerical model for a Kevlar/Epoxy and Carbon-Kevlar/Epoxy tube used as an energy absorbing component has been developed and then results have been verified through experiment. The 2D shell element and Chang-Chang failure criterion of LS-DYNA that is commercial explicit FE code was used. Mechanical material properties for the model were obtained by material testing in advance. The numerical results were compared with quasi-static test results under axial compressive loading at 10mm/min. From the results, in the case of the Kevlar/Epoxy tube, load-crushed displacement curves were very close to the experiments and SEA (specific energy absorption) shows a good agreement with experimental one within less than 6%. However, the Carbon-Kevlar/Epoxy tube shows some differences with the experimental results.

A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM (유한요소법을 이용한 냉각홴의 진동 및 간섭에 관한 연구)

  • Seo Jong-Hwi;Song Ha-Jong;Park Tae-Won;Kim Joo-Yong;Jung Il-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.903-909
    • /
    • 2004
  • A CFA(cooling fan assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

Dynamic Bearing Pressure of Inverted T-type Retaining Walls Subjected to Seismic Motion (지진시 동토압을 받는 역 T형 옹벽의 접지압 산정에 관한 연구)

  • Lee, Jin-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.35-45
    • /
    • 2012
  • Pseudo static analysis using the Mononobe-Okabe method and numerical analysis considering a small strain nonlinearity from the soil were performed to determine the bearing pressure changes of the inverted T-type retaining wall subjected to earthquake motions. In many cases, an inverted 'T' type retaining wall of more than 10 m shows bearing capacity failure under earthquake conditions, despite showing sufficient bearing capacity during normal conditions. The most important reason for this is the change of the effective base area during an earthquake. In this paper, the change of the effective base area of an inverted 'T' type wall is analyzed by using finite difference element code (FLAC). In addition, the effect of dynamic bearing capacity coefficients (which has been suggested by several researchers but not adopted in current design codes and procedures) was verified.