• Title/Summary/Keyword: Factor of Safety

Search Result 4,662, Processing Time 0.033 seconds

Analysis of collapse course of mudstone cut slope and suggest countermeasure (이암 절토 사면의 붕괴 요인 분석 및 대책방안 제시)

  • Park, Min-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.123-131
    • /
    • 2018
  • This study analyzed the collapse course of a mud stone cut slope during the construction of a express and suggested a countermeasure. Experiments were carried out on bedrock mudstone to investigate the engineering characteristics and the slope stability analysis at the time the design was reviewed. In addition, stability analysis, considering the strength softening characteristics of the slope due to the Swelling-Slaking phenomenon, was also performed. As a result of the Swelling-Slaking test, the slake durability was Low-Medium, and the swell potential was Very Low. A review of the stability analysis performed at the time of the design showed different results from the actual results because LEM analysis had been performed without considering the engineering characteristics of mudstone. As a result of additional stability analysis considering the strength softening characteristics, the slope collapse point and the maximum shear strain point of the stability analysis were the same and the standard safety factor was not satisfied. As a countermeasure, a slope mitigation method was found to be most appropriate. The mitigation slope was calculated by Finite element Analysis. A comparison with BIPS to determine the applicability of a mitigation slope revealed most of the unconsolidated mudstone.

Study on the Structural Optimization based on Equivalent Static Load under Dynamic Load (동하중을 받는 구조물의 등가정하중 기반 구조 최적화 연구)

  • Kim, Hyun-Gi;Kim, Euiyoung;Cho, Maenghyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.421-427
    • /
    • 2014
  • Most of the structure of the real world is influenced under dynamic loads. However, when structure analysis and the structural optimization is performed, it is assumed that the static load acts on structure. When considering the actual load of dynamic loads in order to take into account a variety of loads, computational resources and time becomes a big burden in terms of cost. However, considering only the simple static load condition is not preferable for structural safety. For this reason, a lot of studies have been conducted trying to compensate this trouble by applying weight factor or replacing dynamic load with the equivalent static load. In this study, structural optimization techniques for structures under dynamic loads is proposed by applying the equivalent static load. From previous study, after determining the positions of equivalent static load based on primary degrees of freedom, the equivalent static load is calculated through the optimization process. In this process, the equivalent static load optimization of previous research is complemented by adding constraints to avoid excessively large load extraction. In numerical examples, dynamic load is applied to the truss structure and the plate. Then, the reliability of the proposed optimization technique is verified by carrying out size optimization with the equivalent static load.

A Study on the shelf-life of IR screening smoke launcher grenade (적외선 차장 연막유탄 신뢰도 및 저장수명 연구)

  • Lee, Jongchan;Lee, Junhyuk;Jung, Hyunsuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.437-445
    • /
    • 2020
  • Smoke grenades are the primary means of protection used by tanks to disrupt enemy detection systems. Such smoke grenades are a critical factor that determines the survival of tanks in the engagement of ground weapon systems, but it can only be used once. Owing to its destructive property, the performance and safety of the smoke grenade cannot be confirmed prior to use. Therefore, the reliability of smoke grenades can be evaluated through various tests during the storage period. This paper presents the results of estimating the reliability and shelf life of IR screening smoke grenade launchers based on the result of the Ammunition Stockpile Reliability Program conducted in 2019. Among the smoke grenade launcher lots currently stored, 16 lots and samples were selected for each year of manufacture and tested. The reliability and shelf life were estimated by examining the number of defects and the change in quality characteristics of each test item. The results of this study can be used to assess the reliability of the smoke grenade launchers and to improve the quality of manufacturing sites.

Processing factors of azoxystrobin in processed ginseng products (인삼 가공품 중 azoxystrobin의 가공계수)

  • Lee, Jae-Yun;Noh, Hyun-Ho;Lee, Kwang-Hun;Park, Hyo-Kyoung;Oh, Jae-Ho;Im, Moo-Hyeog;Kwon, Chan-Hyeok;Lee, Joong-Keun;Woo, Hee-Dong;Kwon, Ki-Sung;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.222-229
    • /
    • 2012
  • This study was carried out to evaluate the residual characteristics of azoxystrobin in fresh ginseng and calculate its processing factors in processed products, such as dried ginseng, red ginseng and their extracts. Azoxystrobin was sprayed annually onto four-year-old ginseng according to its pre-harvest interval (PHI) for two years. Harvested ginsengs were processed according to the commercially well-qualified conventional methods provided by the Korea Ginseng Corporation. Limits of detection (LODs) of azoxystrobin in fresh ginseng and its processed products were 0.001 and 0.002 mg/kg, respectively. Also limits of quantitation (LOQs) in fresh ginseng and its processed products were 0.003 and 0.007 mg/kg, respectively. Recoveries of the analytical methods in fresh ginseng and its processed products ranged from 69.3 to 114.8%. Highest residue amounts in fresh ginseng and its processed products were 0.025 and 0.118 mg/kg, respectively. Processing factors of the processed products ranged from 1.85 to 3.17 in four-year-old ginseng and from 2.48 to 5.84 five-year-old ginseng.

A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR (콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구)

  • Han, Bong-Hoon;Seo, Dong-Ho;Kwon, Young-Hee;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.23-32
    • /
    • 2017
  • Foam block, popularized as the self-interior goods, is susceptible to fire since the main material is the polyethylene flammable synthetic resin. However, it is widely used in homes, offices, and multi-use facilities. In order to understand the fire characteristics of the foam block, two kinds of foam blocks sold in the market (non-fire retardant and fire retardant) were evaluated according to standard of KS F 5660-1 (Reaction to fire test). In addition, the hazard analysis of the gas generated by the combustion of the specimen was performed using the FTIR gas analyzer. The cone calorimeter test showed that the ignition and flame combustion of both two specimens were burned as soon as the radiant heat blocking device was removed, and it was confirmed that the flame could become a rapid propagation factor during the fire. The analysis of the combustion gas through the FTIR gas analyzer showed that both the carbon dioxide and carbon monoxide classified as the common combustion gases and the acrolein, ammonia, and hydrogen cyanide causing serious damage to the human body were detected substantially. This study showed that a foam block product has high ignitionability and generates toxic gases. Hence, it is urgently required to establish the standards used for properly classifying the combustion characteristics of the material on the basis of the use conditions of a foam block product and to prepare the standards on the purpose of use.

Comparative Inactivation of Hepatitis A Virus and Murine Encephalomyocarditis Virus to Various Inactivation Processes (바이러스 불활화 공정에 대한 Hepatitis A Virus와 Murine Encephalomyocarditis Virus의 민감도 비교)

  • Kim, In-Seop
    • Korean Journal of Microbiology
    • /
    • v.39 no.4
    • /
    • pp.242-247
    • /
    • 2003
  • Murine encephalomyocarditis virus (EMCV) has been used as a surrogate for hepatitis A virus (HAV) for the validation of virus removal and/or inactivation during the manufacturing process of biopharmaceuticals. Recently international regulation for the validation of HAV safety has been reinforced because of the reported cases of HAV transmission to hemophiliac patients who had received ntihemophilic factors prepared from human plasma. The purpose of the present study was to compare the resistance of HAV and EMCV to various viral inactivation processes and then to standardize the HAV validation method. HAV was more resistant than EMCV to pasteurization (60oC heat treatment for 10 hr), low pH incubation (pH 3.9 at 25oC for 14 days), 0.1 M NaOH treatment, and lyophilization. EMCV was completely inactivated to undetectable levels within 2 hr of pasteurization, however, HAV was completely inactivated to undetectable levels after 5 hr treatment. EMCV was completely inactivated to undetectable levels within 15 min of 0.1 M NaOH treatment, however, residual infectivity of HAV still remained even after 120 min of treatment. The log reduction factors achieved during low pH incubation were 1.63 for HAV and 3.84 for EMCV. Also the log reduction factors achieved during a lyophilization process of antihemophilic factor VIII were 1.21 for HAV and 4.57 for EMCV. These results indicate that HAV rather than EMCV should be used for the virus validation study and the validation results obtained using EMCV should be precisely reviewed.

Development of Novel Method of Seismic Slope Stability Analysis (신(新) 유사정적 사면안정해석 기법 개발)

  • Yun, Seung;Park, Duhee;Lee, Seungho;Hwang, Youngchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • The seismic slope stability is most often evaluated by the pseudo-static limit analysis, in which the earthquake loading is simplified as static inertial loads acting in horizontal and/or vertical directions. The transient loading is represented by constant acceleration via the pseudostatic coefficients. The result of a pseudostatic analysis is governed by the selection of the value of the pseudostatic coefficient. However, selection of the value is very difficult and often done in an ad hoc manner without a sound physical reasoning. In addition, the maximum acceleration is commonly estimated from the design guideline, which cannot accurately estimate the dynamic response of a slope. There is a need to perform a 2D dynamic analysis to properly define the dynamic response characteristics. This paper develops a new hybrid pseudostatic method that links the modified one-dimensional seismic site response analysis and the pseudostatic algorithm. The modified site response analysis adjusts the density of the layers to simulate the change in mass and weight of the layers of the slope with depth. Multiple analyses were performed at various locations within the slope to estimate the change in seismic response of the slope. The calculated peak acceleration profiles with depth from the developed procedure were compared to those by the two-dimensional analyses. Comparisons show that the two methods result in remarkable match. The calculated profiles are used to perform pseudostatic analysis. The results show that use of peak or a fraction of acceleration at the surface can seriously underestimate or overestimate the factor of safety, and that the proposed procedure significantly enhances the reliability of a standard procedure.

  • PDF

Development of Raising Device for Greenhouse Column Using a Pneumatic Cylinder (공압실린더를 이용한 온실기둥 상승장치 개발)

  • Lee, Hyun June;Park, Eun Mi;Shin, Dong Chang;Choe, Jung Seob;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • As many consumers prefer good quality food, farms have used various facilities to cultivate products for satisfying their desires. Among them, the most representative facilities are plastic and glass multi-span greenhouse. The height of both plastic greenhouse and glass greenhouse is around three meters high in Korea. As a result, the crop productivity is limited. The solution is to increase the height of the greenhouses to improve the greenhouses' environment. The device for raising columns consists of a stop device, a pneumatic cylinder, and a vertical member. Pneumatic cylinders were designed with a diameter of 160 mm and a stroke length of 50 mm, taking into consideration the safety factor of 1.5. In addition, the air flow was controlled by nozzle to achieve a time of less than 30 seconds per stroke. It was calculated that $21.5L{\cdot}min^{-1}$ of air was needed to complete in less than 30 seconds. Accordingly, the diameter of the nozzle is designed to be 0.5 mm. When the pressure was 0.9 MPa, the average raising force was 13,805N, which was close to the calculated value of 15,612N. The field test results show that any inconsistency in the row columns was not generated. and that it is considered applicable to the actual glass and plastic greenhouses.

Preliminary Design of a Urban Transit Passenger Guidance System Using Congestion Management Model (혼잡관리 모형을 이용한 도시철도 이용객 동선유도시스템 기본설계)

  • Kim, Kwang-Mo;Park, Hee-Won;Kim, Jin-Ho;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3610-3618
    • /
    • 2015
  • The congestion of railway vehicle and station shows up to 220%. Especially, transfer resistance of passenger increase rapidly by the collision of circulation. So increment of travel time, occurrence of safety accidents act as a factor that inhibits the utilization of urban railway station. In this paper, to improve traveling speed and comfort of urban rail passengers, urban transit passenger guidance system using congestion management model is proposed. The congestion management model that can mitigate a recurring/non-recurring congestion is constructed and the preliminary design of the system (middleware system, control system, guidance drive system) is carried out. Passenger Guidance System is configured by step for changing the external data into a form usable by the algorithm, step to perform the congestion management algorithm using the real-time data and historical data, step to control device based on the value that is calculated by congestion management algorithm, step to drive the device based on the information in the control system and circulation guidance devices. In the future, detail design will be performed based on the preliminary design. A prototype of the various devices according to the station structures and locations will be made. The control module of guidance device will be developed.

The Study of Correlation Between the Balance, Cognition and Activity of Daily Living in Stroke Patients (뇌졸중 환자의 균형, 인지, 일상생활 평가의 상관성 연구)

  • Kang, Bo-Ra;Jeong, Eun-Song;Kim, Jae-Hee;Ha, Yoo-Na
    • Journal of Korean Society of Neurocognitive Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.45-52
    • /
    • 2018
  • The purpose of the present study was to determine correlations between the Berg Balance Scale (BBS), Montreal Cognitive Assessment-Korean (MoCA-K) and Modified Barthel Index (MBI) targeting stroke patients, and it seeks to analyze the influence among each factor to establish the fundamental research in evaluating the functional performance capability of stroke patients. The study was conducted between December 2017 and March 2018 and the target of the study was 34 stroke patients who are hospitalized and treated in Y rehabilitation hospital located in Goyang city. Following in criteria of how participants were selected. First, a person without the onset of 6months or more. Second, a person who can communicate and score over 20 points on MMSE-K. Third, a person without unilateral neglect. Fourth, a person without lower motor neuron lesion and orthopedic disease on the bilateral lower extremity. Fifth, a person without audiovisual problem and history of using drug or surgery that influence athletic function. sixth, patients who agreed on participating in the study. The evaluation was processed by measuring BBS, MoCA-K, and MBI with the occupational therapist and physical therapist. Also, one assistant was participated in measuring balanced ability for the safety reason. It was found that significantly correlates (p<.01) with BBS and MoCA-K (r=.459), BBS and MBI (r=.550), MoCA-K and MBI (r=.565). This study is meaningful that it provided the basis for the active use of BBS, MoCA-K and MBI as a clinical evaluation tool and its usefulness.