• 제목/요약/키워드: Factor V

검색결과 2,474건 처리시간 0.029초

$90-260V_{rms}$ 입력범위를 갖는 단일전력단 고역률 컨버터 (Single-Stage High Power Factor Converter for $90-260V_{rms}$ Input)

  • 김학원;문건우;조관열;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.205-210
    • /
    • 2001
  • A new single stage power factor corrected AC/DC converter has been proposed, that is unified with buck topology and suitable for universal input. The design example of the proposed converter lot 5V 12A application has been presented. The design considerations and simulation results for the proposed converter have been shown. The simulation results show that the line input current harmonics can meet IEC 1000-3-2 Class D requirements for the line input voltage from 90 to 260V.

  • PDF

A Two-stage Process for Increasing the Yield of Prebiotic-rich Extract from Pinus densiflora

  • Jung, Ji Young;Yang, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권4호
    • /
    • pp.380-392
    • /
    • 2018
  • The importance of polysaccharides is increasing globally due to their role as a significant source of dietary prebiotics in the human diet. In the present study, in order to maximize the yield of crude polysaccharides from Pinus densiflora, response surface methodology (RSM) was used to optimize a two-stage extraction process consisting of steam explosion and water extraction. Three independent main variables, namely, the severity factor (Ro) for the steam explosion process, the water extraction temperature ($^{\circ}C$), and the ratio of water to raw material (v/w), were studied with respect to prebiotic sugar content. A Box-Behnken design was created on the basis of the results of these single-factor tests. The experimental data were fitted to a second-order polynomial equation for multiple regression analysis and examined using the appropriate statistical methods. The data showed that both the severity factor (Ro) and the ratio of water to material (v/w) had significant effects on the prebiotic sugar content. The optimal conditions for the two-stage process were as follows: a severity factor (Ro) of 3.86, a water extraction temperature of $89.66^{\circ}C$, and a ratio of water to material (v/w) of 39.20. Under these conditions, the prebiotic sugar content in the extract was 332.45 mg/g.

위선암종의 예후인자로서 p53, CD44v6과 VEGF 단백 발현 (Expression of p53, CD44v6 and VEGF in Gastric Adenocarcinomas)

  • 박언섭;이창영;이태진;김미경;유재형
    • Journal of Gastric Cancer
    • /
    • 제1권1호
    • /
    • pp.10-16
    • /
    • 2001
  • Purpose: The p53 protein is a tumor supressor gene, and its mutation is associated with biologic aggressiveness. CD44v6, one of the CD44 family, is a cell surface glycoprotein that plays a role in cancer invasion and metastasis. Vascular endothelial growth factor (VEGF) is another recently identified growth factor with significant angiogenic properties. The purpose of this study was to investigate p53, CD44v6, and VEGF expressions to determine whether degree of expression was related to pathological parameters such as Lauren's classification, depth of invasion, and lymph node metastasis. Materials and Methods: Immunohistochemical stains of p53, CD44v6, and VEGF in formalin-fixed paraffin-embedded tissue sections of 125 gastric adenocarcinomas were done. Results: The overall expression rates of p53, CD44v6, and VEGF were $54.4\%$ (68/125), $36.8\%$ (46/125), and $48.0\%$ (60/125), respectively. The p53, not CD44v6 and VEGF was higher in intestinal-type gastric carcinomas by Lauren's classification. The expressions of p53, CD44v6, and VEGF were statistically correlated with depth of tumor invasion. The expression of CD44v6 was higher in the lymph node metastatic group than in the negative group. The p53 expression was significantly associated with VEGF expression. Conclusions: These data suggest that the expressions of p53, CD44v6, and VEGF are biologically related to malignancy. The p53 and CD44v6 expressions are independent; however, p53 gene mutation is one of the contributing factors to VEGF expression in gastric adenocarcinoma.

  • PDF

링레이저 자이로의 몸체진동 검출센서를 이용한 dither-stripping 연구 (A study on the dither-stripping with dither motion sensor of a ring laser gyroscope)

  • 심규민;임후장
    • 한국항공우주학회지
    • /
    • 제31권5호
    • /
    • pp.63-71
    • /
    • 2003
  • 본 논문에서는 몸체진동형 링레이저 자이로에서 몸체진동을 검출하기 위한 각속도 센서 출력을 V-F 변환하여 링레이저 출력에서 몸체진동에 의한 출력을 제거하는 dither-stripping 방법에 대하여 논의하였다. Dither-stripping에서는 V-F 출력펄스와 링레이저 출력펄스간의 환산계수를 산출하는 방법과 V-F 출력펄스의 offset를 보정해주는 방법이 중요하다. 각속도 센서의 출력을 V-F 변환하여 dither-stripping하는 경우에는 offset을 보정하는 과정에서 몸체진동의 진폭잡음에 의한 자이로 출력의 오차가 크게 발생한다. 우리는 V-F 출력펄스를 미분하여 offset을 제거하는 방법을 고안하였다. 이를 위해서는 각속도 센서의 출력을 90deg 위상 이동시켜서 각도신호를 만들고 V-F 변환해야 하며 링레이저 출력의 위상도 샘플링의 반주기만큼 이동시켜야 한다. 그리고 두 펄스간의 환산계수는 분산을 이용하여 산출하였다. 이러한 각도신호 미분방식의 dither-stripping에 의하여 개선된 결과를 얻을 수 있었다.

제주 풍력발전 단지의 V47-660 kW 시스템의 역률개선에 관한 연구 (A Study on the Power Factor Improvement of V47-660 kW Wind Turbine Generation System in Jeju Wind Farm)

  • 김일환;전영진;김정웅;강경보;허종철;김건훈
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.45-53
    • /
    • 2003
  • This paper presents a study on the power factor improvement of V47- 660 [kW] Wind Turbine Generation System (WTGS) in Jeju wind farm, as a model system in this paper. In this system, the power factor correction is controlled by the conventional method with power condensor banks. Also, this system has only four bank steps, and each one capacitor bank step is cut in every one second when the generator has been cut in. This means that it is difficult to compensate the reactive power exactly according to the variation of them. Actually, model system has very low power factor in the area of low wind speed, which is almost from 4 to 6 [m/s]. This is caused by the power factor correction using power condenser bank. To improve the power factor in the area of low wind speed, we used the static var compensator(SVC) using current controlled PWM power converter using IGBT switching device. Finally, to verify the proposed method, the results of computer simulation using Psim program are presented to support the discussions.

Spherical Indentation Testing에 의한 1Cr-1Mo-0.25V 강의 기계적 물성 평가 (Spherical Indentation Testing to Evaluate Mechanical Properties In 1Cr-1Mo-0.25V Steel)

  • 이종민;남영현;남승훈;이승석;이억섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.266-271
    • /
    • 2001
  • Spherical indentation technique was developed to evaluate the flow properties of metallic materials in carbon steel, stainless steel and alloys, etc. Through the spherical indentation test, differently degraded 1Cr-1Mo-0.25V steel's mechanical properties were observed and compared with conventional standard test data. The flow properties of 1Cr-1Mo-0.25V steels were estimated by analyzing the indentation load-depth curve. To characterize the flow property, we used material yield slope and constraint factor index rather than strain-hardening exponent because the variation of strain-hardening exponent was very little and the data showed irregularly. And the constraint factor's effect was small when the material yield slope was taken into account.

  • PDF

V2O5가 Pb(Sb1/2Nb1/2)O3-Pb(Ni1/3Nb2/3)O3-Pb(Zr, Ti)O3세라믹스의 유전 및 압전특성에 미치는 영향 (The Effect of V2O5 on the Dielectric and Piezoelectric Characteristics of Pb(Sb1/2Nb1/2)O3-Pb(Ni1/3Nb2/3)O3-Pb(Zr, Ti)O3Ceramics)

  • 류주현;남승현;이수호
    • 한국전기전자재료학회논문지
    • /
    • 제16권8호
    • /
    • pp.676-680
    • /
    • 2003
  • In this study, to develop the low temperature sintering ceramics for piezoelectric transformer, PSN-PNN-PZT system ceramics were manufactured as a function of V$_2$O$_{5}$ addition, that is the low melting point oxide. Its dielectric and piezoelectric characteristics were investigated. With increasing the amount of V$_2$O$_{5}$ addition, electromechanical coupling factor(kp) and mechanical quality factor(Qm) were decreased. For piezoelectric transformer application, the 0.1wt% V$_2$O$_{5}$ added specimen sintered at 1,00$0^{\circ}C$ showed the proper value of $\varepsilon$r=1,590, kp=0.51 and Qm=748.m=748.

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

Response modification factor of suspended zipper braced frames

  • Abdollahzadeh, Gholamreza;Abbasi, Mehdi
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.165-185
    • /
    • 2015
  • The suspended zipper bracing system is suggested to reduce the flaws of ordinary zipper braced and concentric inverted V braced frames. In the design procedure of suspended zipper bracing systems, columns and top story truss elements are strengthened. This bracing system show different performances and characteristics compared with inverted V braced and ordinary zipper frames. As a result, a different response modification factor for suspend zipper frames is needed. In this research paper, the response modification factor of suspended zipper frames was obtained using the incremental dynamic analysis. Suspended zipper braced frames with different stories and bay lengths were selected to be representations of the design space. To analyze the frames, a number of models were constructed and calibrated using experimental data. These archetype models were subjected to 44 earthquake records of the FEMA-P695 project data set. The incremental dynamic analysis and elastic dynamic analysis were carried out to determine the yield base shear value and elastic base shear value of archetype models using the OpenSEES software. The seismic response modification factor for each frame was calculated separately and the values of 9.5 and 13.6 were recommended for ultimate limit state and allowable stress design methods, respectively.

수동역률 개선회로를 이용한 110/220V 겸용 정출력 안정기 개발 (The development of 110/220V alternative static output ballast by using passive power factor correction circuit)

  • 송명석;조계현;박종연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2004
  • In this paper, we propose the passive PFC(Power Factor Correction) circuit of an electronic ballast with the constant power the detection circuit for 110 or 220 volt. The proposed PFC circuit is composed with the modified dither circuit and the input voltage detection circuit. We have concluded that the proposed method is the attractive method to improve of power factor for the electronic ballast with the input voltage regulation and it is a similar experimental results with other active power factor correction method using other PWM ICs.

  • PDF