• Title/Summary/Keyword: Facing block

Search Result 46, Processing Time 0.02 seconds

An Experimental Study on Connection Strength between Tie-bar and Facing block composing Reinforced Earth (보강토옹벽을 구성하는 타이바와 전면블록의 연결강도에 관한 실험연구)

  • Lee Seung-Hyun;Kim Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.404-408
    • /
    • 2006
  • In this paper, connection strength between facing block and tie-bar was investigated through experimental study with varying in-fill material such as concrete, soil and crushed stone. Also, connection strength between anchor block and tie-bar was investigated with varying in-fill material. According to the experimental results, in case of using in-fill concrete, connection strength between facing block and tie-bar was larger than allowable tension load of tie-bar. Whereas in case of using in-fill soil or crushed stone, connection strength between facing block and tie-bar was less or similiar to allowable tension load of tie-bar. Connection strength between anchor block and tie-bar for which crushed stone was used as in-fill material, was larger than allowable tension load of tie-bar.

  • PDF

The Role of Wall Facing on the Stability of Reinforced Soil Wall (전면판의 연속성이 보강토체의 안정성에 미치는 영향)

  • 임유진;정종홍
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.465-472
    • /
    • 1999
  • A small scale model reinforced soil wall was constructed in a laboratory to investigate role of the wall facing and the effect of construction sequence on the wall. A panel type facing system and a block facing system are introduced for test. These two different types of facing adapt different construction procedure. The model wall is built with geogrid reinforcement, sand, and the facings on rigid surface. The model wall is instrumented with earth pressure gauges, LVDTs, and strain gauges. It is found in this study that the reinforced soil wall system built with geogrids and panel type facing system be the safest reinforced soil wall ever compared to the block type facing. Thus, it is recommended that study for the wall system be necessary for further wide usage in the future.

  • PDF

Troubles and Countermeasures of Geogrid-Reinforced Earth Wall (지오그리드 보강토 옹벽의 설계/시공에 따른 문제점과 대책방안)

  • 조삼덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.315-321
    • /
    • 2001
  • Since 1984, block-type reinforced earth wall with geogrid reinforcement has been widely used for retaining wall applications till now in Korea. The use of geogrid as a reinforcement in the reinforced earth wall is steadily increased in an amount over 1,500,000㎡ in a year However, still need exists that some problems in design and construction practices should be made to review, Therefore, this paper reviewed reasonable criteria for selection of backfills, design details considering the effect of the upper soil slope on reinforced earth wall, horizontal displacement of facing block during compaction, and the damage of geogrid reinforcements on the edge part of facing block. Finally, alternative methods of measures on those problems are proposed.

  • PDF

A Study on Connection Strength Evaluation of Wall Facing/Geogrid Using I-type Connection Device (I형 연결장치를 이용한 전면블록/지오그리드 보강재의 연결강도 평가)

  • Han, Jung-Geun;Hong, Ki-Kwon;Cho, Sam-Deok;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.45-52
    • /
    • 2009
  • The use of geogrid-reinforced earth wall technologies has progressed rapidly over the past 10 years in Korea because these technologies have advantages such as economical efficiency, graceful appearance, and easy construction. The geogrid used in the reinforced earth wall with concrete block facing can be subjected to damage among the upper and lower blocks and at the interface between the block and the geogrid. Therefore, when design of the geogrid-reinforced soil walls the required connection strength of the geogrid to the wall facing is an issue. In this study, new connection system between facing block and geogrid is developed to improve the damages of geogrid in the existing connection systems. The new connection devices are made of steel and have I-shape. This paper describes the test method and results of the laboratory testing for determination of connection strength in connection system using the I-type connection device.

  • PDF

Analysis for Behavior of Green Geosynthetic Reinforced Soil Walls by Laboratory Model Tests (실내모형실험에 의한 녹화보강토벽의 거동분석)

  • Cho, Yong-Sung;Kim, You-Seong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2003
  • The existing geotextile reinforced soil wall methods have a demerit in terms of esthetic view because concrete panel or block are used as wall facing of the methods. If grass planting walls could be used in reinforced soil slope or wall methods, efficiency of the methods would be increased with maximization of advantage of the methods. In this study, some possible methods in which grass planting wall is used as wall facing are devised. A series of laboratory model tests were performed to investigate the behavior of newly devised methods in order to compare with the results of each others. As a major result, it was found that this kinds of grass wall facing methods could be accepted as a new construction method even in the sense of stability.

  • PDF

Reduction Effect on Surface Temperature of Reinforced Soil Wall with Vegetated Facing (전면 식생형 보강토 옹벽의 표면온도 저감 효과)

  • Jung, Sunggyu;Lee, Kwangwu;Cho, Samdeok;Kim, Juhyong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.53-60
    • /
    • 2013
  • A new type of reinforced earth wall(REW) system is developed with vegetated facing which provides proper environment for long-term vegetation and also applicable to high retaining wall system. Vegetated retaining wall is a green alternative for retaining walls and an effective way to reduce heat island effect than conventional block or concrete systems. Several construction sites using vegetated facing is observed to monitor adaptation state of vegetation and estimate surface temperature of wall facing over two years. It was observed that a number of plants including Siberian chrysanthemum adapt well to the inside of the facing blocks because vegetation bag helps to keep a proper condition for vegetation. According to the results using thermographic camera, average surface temperature of vegetated facing is higher for all ranges of coverage ratio of vegetation. The increment of average surface temperature of vegetated facing is larger than that of non-vegetated facing when the air temperature rises, and vice versa.

Development of Common Reinforced Concrete Block for Slope Protection (사면보호용(斜面保護用) 범용보강(凡用補强)콘크리트블록의 개발(開發))

  • Ryu, Neung-Hwan
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.404-409
    • /
    • 2005
  • The reinforced concrete blocks for reinforced earth layer are combined with soil structures consisted of facing unit, reinforcing materials and soil. Those environmentally friendly facing units of reinforced concrete blocks are made of mine waste and tailing and that will be played a role of the effects of recycling use of wasted resources. The block are consisted of three types as curved or straight in order to control topography. The systems are also not limited to wall hight so that they are effectively used for protecting the slope of banking and cutting of earth works. The reinforced concrete blocks developed this time will be effectively applied for not only retaining wall, road, park, golf course, public office building constructions but also protecting of slope stabilization projects.

  • PDF

Effect of Magnetic Strength of Three-dimensionally Arranged Magnetic Barrel Machine on Polishing Characteristics

  • Zhang, Yu;Yoshioka, Masato;Hira, Shin-ichiro;Wang, Zhuqing
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.34-38
    • /
    • 2008
  • Commercially available magnetic barrel machines equipped with permanent magnets have certain limitations: work can only be finished effectively in limited areas of the container because permanent magnets are arranged two-dimensionally on the magnet disk. We overcame this problem by developing a new magnetic barrel machine equipped with a three-dimensional magnet arrangement. The effectiveness of the new machine has already been reported; this study improved the machine's polishing ability by changing the polarity of magnets on a magnet block. Polishing experiments confirmed the most effective arrangement of magnets on the magnet block. An alternating arrangement of north and south poles produced far superior polishing characteristics than a uniform arrangement of the same pole facing outward. Alternating polarity probably causes increased quantities of barrel media to work together. Finally, we introduced stronger permanent magnets to the magnet block, and found that the increased magnetic field also improved polishing ability.

A Study on the Relationship between Urban Block Division and Unit Plans of Korean Modern Traditional Style Houses - Focused on the Ikseon-Dong 166 - (도시형한옥 주거지의 블록구획과 주거평면의 관계에 관한 연구 - 익선동 166번지 사례를 중심으로 -)

  • O, Ukn;Seo, Hyun
    • Journal of architectural history
    • /
    • v.22 no.3
    • /
    • pp.7-14
    • /
    • 2013
  • Ikseon-Dong 166 is one of the traditional urban resident area developed during 1930's. The purpose of this research is to analyze the structural relationship between a conventional housing unit plans and modern block plans based on orthogonal geometry. To fully explore the selling point of the new urban development, the planner or real estate developer in private sector did not abandon or compromise the conventional house layouts, consists of single layer of rooms keeping the main room facing south. This study concludes the following factors connecting the urban and architectural plans. Oblong block plans following east-west direction did not allow the southern exposure of courtyard and main room, which was the absolute requirement for traditional house units, the longer side of block plan followed north-south direction as a result. Considering the possibility of rent, having entrance at the east or west side of individual site enables two separate household maintain their spatial privacy. In addition to the factors mentioned above, when the blocks are to be divided into individual addresses, north-south oblong block plans maintained the length to face the front road minimum while the southern exposure maximized. These factors explains why the private developers maintained their blocks elongated to north-south direction when the block plans laied out by public sectors which did not care that much of southern exposure show random orientation in the view point of solar exposure.

The Application of KOESWall System as a Temporary Structure (임시구조물로서 분리형 보강토 옹벽의 적용사레)

  • 김영윤
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.09a
    • /
    • pp.53-58
    • /
    • 2000
  • The KOESWall system that minimizes the horizontal deformation of reinforced wall effectively was developed bt E&S Eng. Co., Ltd. in 1999. Due to its systematical feature i.e. isolated construction method. KOESWall system is able to use as temporary structures more economically without the facing block. In this report, it is shown that the case history of KOESWall as a temporary soil retaining structure and the field measuremnets.

  • PDF