A Study on the Architectural facility standards of integrated child care facility (통합보육시설의 시설 및 설비 기준에 관한 연구)

  • Kim Young-Eun;Park Hyeon-Soo;Lee Keon-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.136-143
    • /
    • 2006
  • This research proposes the importance of physical environment if integrated early childhood education. For a successful integration of children's education, we processed fundamental research on requirements of facility and equipments, looking at related standards and code on handicapped person's convenience facility. Also, this research alms at providing first step to establish evaluation method and quality assurance standards of integrated child care facility, regarding space planning of handicapped children. By examining home and abroad material and analyzing handicapped children's convenience facility standards, this research pursues improving the basis of planning criteria. As present criteria of relevant regulations appears not to handle detailed facility standards, and the handicapped people's facility is for childhood education, it is necessary first to differentiate indispensable equipments from optional one, then categorize them into more specific needs.

An Evaluation of User's Facility and Suggestion for the Improvement on the Interior Design of Metropolitan Railroads Trains - Focus on the opening 14 metropolitan railroad lines in Seoul through checklist - (도시철도 차량 실내의 이용자 시설 평가와 개선방향 - 체크리스트를 통하여 수도권 노선에 운행 중인 14개 철도 차량을 대상으로 -)

  • Moon, Suh-Hyun;Kim, Gu-Seul;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • User-oriented Design is necessary in planning the interior design of Metropolitan Railroads trains, since this is a typical means of transportation in this modem society and all ages people with different body scale use this facility. However, there are little studies about facility panning and zoning of Metropolitan Railroads train considering users. Therefore, in this study, after completing the checklist based on the current legal standards of facility installation of South Korea and Japan, we examined user's facility and suggest several improvement of the opening 14 metropolitan railroad lines in Seoul. Then, we evaluated this facilities according to 41 standards; general facility(24 standards), safety facility(4 standards), guide facility(11 standards), other facility(4 standards). The result of this study may be summarized as follows. 1) General facility has to be designed to obtain lots of room for storage and this facility should be fixed up tightly with secure system. 2) Safety facility should be designed to minimize a difference of floor-level between threshold of train and ground. Also, using various color and material could help passengers to distinguish different space and facility. 3) Guide facility should be designed to guide passengers to the accurate direction with proper sign design in the pathway of Metropolitan railroad train. Also, more various color, which based on the research about physiological and psychological effect, should be used to guide people. 4) Other facility should equip more visual system using common good and informative contents. Through this study, we try to understand the current interior physical condition of Metropolitan Railroads trains. However, for future studies, it is expected to supplement evaluation standards considering aesthetic design, environmental improvement of indoor air quality and the satisfaction and demand of Metropolitan Railroads trains.

Analysis of Facility Standard for Elderly Welfare Facility by Universal Design Principle and Guideline: Focusing on Legal Regulations (유니버설 디자인의 원리와 지침에 의한 노인복지시설 기준 분석: 법률 규정을 중심으로)

  • Kim, Soo-Jung
    • Journal of Industrial Convergence
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • The purpose of this study is to analyze the facility standards of the elderly welfare facilities applying the seven principles of the universal design. The facility standards of the elderly welfare facilities were limited to the provisions of the "Enforcement Regulation of the Elderly Welfare Act". There are few legal regulations applying the universal design in the construction of the elderly welfare facilities. The facility standards are set only with the minimum requirements such as securing the safety of the user, securing the space area, functional convenience, and risk prevention. However, the contents of the regulations are limited to the minimum standards for functional convenience and safety required for living. In conclusion, in the elderly welfare facilities, the notion of universal design, which considers not only the elderly, but also service providers, employees, and general visitors, should be considered.

  • PDF

A study on the space composition and area planning of neonatal intensive care unit through the case of regional neonatal intensive care centers (신생아 집중치료 지역센터 사례를 통해 본 신생아 집중치료실(NICU) 공간 구성 및 면적 계획에 관한 연구)

  • Lee, Kee hwan;Park, Seo won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 2024
  • Purpose: This study is to present basic data and standards for calculating the space composition and area required when planning a neonatal intensive care unit. Methods: Review domestic and foreign facility standards and regulations related to the current neonatal intensive care unit, select a regional neonatal intensive care center designated by the Ministry of Health and Welfare as a case hospital, and organize a space program for the construction plan of the neonatal intensive care unit through analysis of characteristics such as facility size and function composition. Results and Implications: The size, facility area, and detailed room composition characteristics of the neonatal intensive care unit in Korea were confirmed, and essential rooms and appropriate areas were derived when planning the construction of the neonatal intensive care unit. Korea's legal facility standards related to neonatal intensive care units are lower than the actual hospital status and overseas standards, and the facility standards of the medical law need to be improved.

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.

Assessment of the Child Care Centers' Foodservice Facility and Development of the Kitchen Facility Model based on the General Sanitation Standards and Guidelines (영유아 보육시설의 조리실 시설 현황 조사 및 조리실 시설 설계 기준안 개발)

  • Park, Yeong-Ju;Gwak, Dong-Gyeong;Gang, Yeong-Jae;Jeong, Hong-Gwan
    • Journal of the Korean Dietetic Association
    • /
    • v.9 no.3
    • /
    • pp.219-232
    • /
    • 2003
  • The purposes of this study were to assess the child care centers' foodservice facility, and to develop the kitchen facility model based on the general sanitation standards and guidelines in order to provide basic information for a plan review to build or renovate child care centers' foodservice facility. The scopes of the study include : 1) field assessment of the foodservice management practices and facilities in 8 public child care centers, and 2 private child care centers which they are subsidized from the government as public child care centers, 2) development of child care centers' kitchen facility model based on the General Sanitation Standards and Guidelines. The results of this study can be summarized as follows : 1. Field Assessment of the Child Care Centers' Foodservice Facility Average number of children in child care centers was 78.0$\pm$24.20, the average space of kitchen was 15.13$\pm$4.25($m^2$). Especially, the average space of kitchen was 18.49$\pm$4.35($m^2$) with enrollment capacity of 90~120 children in child care centers. The inventory level of most foods was relatively low except rice and kimchi. Kitchen facilities and equipments were similar to those of home kitchen and did not meet the standards of institutional practice. Therefore, the director in child care centers should recognize the importance of the sanitation management and pay more attention to the renovation of foodservice facilities as well as sanitation management practices. 2. Development of the Kitchen Facility Model based on the General Sanitation Standards and Guidelines The kitchen facility plan model with enrollment capacity of 100 children was developed based on the results of field assessment and literature review. Suggested kitchen space was 34.16$m^2$(6,100mm×5,600mm). This space was bigger than the results of field survey or precedent study, considered appropriate to implement the general sanitation standards. The main feature of the developed kitchen facility plan and model was product flow in one direction from the arrival of the raw material to the finished product in order to prevent cross contamination and to improve working efficiency.

  • PDF

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

A Study on Industrial Site Annexed Parking Unit Calculation Method by Considering Facility Use and Scale Characteristics (용도 및 규모특성을 고려한 산업단지 공장시설의 부설주차장 설치기준 개선방안 연구)

  • Ahn, Woo-Young;Lee, Seon-Ha
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups in terms of recreation, culture and assembly, housing, factory, and so on, in which same grouped facilities have uniform parking standards. The local governments have authority to itemize groups and adjust parking standards within ${\pm}50%$ ranges. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a systematic method of analyzing parking generation unit for factory facilities in industrial site in terms of facility use and scale characteristics.

A Study on Parking Generation Forecasting Model for Factory Facilities in Industrial Site (산업단지 공장시설의 주차수요예측모형 구축에 관한 연구)

  • Ahn, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.37-44
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups with 13 parking standards in terms of recreation, culture and assembly, housing, factory, warehouse, and so on, in which same grouped facilities have same parking standards. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a parking generation forecasting model for factory facilities in industrial site in terms of facility use and scale characteristics.

A Study on Proposal of Facility Standard by Research of Safety Accidents at Elderly Housing Welfare Facility (노인주거 복지시설 안전사고 실태조사에 의한 시설기준 제안에 관한 연구)

  • You, Jong-Ok;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.2
    • /
    • pp.7-16
    • /
    • 2011
  • The death toll of the elderly by accidents in 2007 takes 6.5% of total death toll. The lost income from this is estimated to be 17 trillion and 511 billion won. According to CISS of Korea Consumer Protection Board, the number of safety related accidents of the elderly at home in 2006 was 486 cases in 2006 and has gradually increased every year. This thesis created 115 guidelines at 14 spaces as facility evaluation index evaluating the aging friendliness of the facility and safety related accidents generated at elderly resident welfare facility, examined influence variables of safety related accidents with 191 elderly including demographic variable, physical skill variable, social psychological variable and facility environmental variables, and then verified relevance between safety accidents and each influence variable. As a result, it was verified through ANOVA test of SAS Package Program and $x^2$- test that facility environmental variable would be closely related to the accident. In this regard, this study newly proposes the facility standards of aging friendly facility by supplementing them with contents and guidelines of facility evaluation table as ways to reduce safety related facility of the elderly.