• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.029 seconds

Potential repository domain for A-KRS at KURT facility site (KURT 부지 조건에서 A-KRS 입지 영역 도출)

  • Kim, Kyung-Su;Park, Kyung-Woo;Kim, Geon-Young;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.3
    • /
    • pp.151-159
    • /
    • 2012
  • The potential repository domains for A-KRS (Advanced Korean Reference Disposal System for High Level Wastes) in geological characteristics of KURT (KAERI Underground Research Tunnel) facility site were proposed to develop a repository system design and to perform the safety assessment. The host rock of KURT facility site is one of major Mesozoic plutonic rocks in Korean peninsula, two-mica granite, which was influenced by hydrothermal alteration. The topographical features control the flow lines of surface and groundwater toward south-easterly and all waters discharge to Geum River. Fracture zones distributed in study site are classified into order 2 magnitude and their dominant orientations are N-S and E-W strike. From the geological features and fracture zones, the potential repository domains for A-KRS were determined spatially based on the following conditions: (1) fracture zone must not cross the repository; and (2) the repository must stay away from the fracture zones greater than 50 m. The western region of the fracture zones in the N-S direction with a depth below 200 m from the surface was sufficient for A-KRS repository. Because most of the fracture zones in N-S direction were inclined toward the east, we expected to find a homogeneous rock mass in the western region rather than in the eastern region. The lower left domain of potential domains has more suitable geological and hydrogeological conditions for A-KRS repository.

400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries (400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산)

  • Shin, Yun Sung;Kim, yong min;Kim, dong hyun;Jung, nam suk;Lee, hee seock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.295-300
    • /
    • 2015
  • There are various type of particle accelerators such as Kyoungju 100-MeV proton beam accelerator in Korea. And Korea plans to build large particle accelerator such as heavy ion accelerator and 4th generation light source facility. The accelerated high energy particles of these facility produce 2nd neutron after nuclear reaction with target materials. And then these 2nd neutron activate structural materials and surrounding environment. Accordingly, it is important to consider the activation and shielding calculation on design of facility for safety operation. In this study, we tried to calculate and compare the neutron flux from the interaction $^{la}150$ beam with target material(Cu) according to thickness of iron and concrete shielding material by MCNPX 2.7 with nuclear library JENDL/HE 07and la150. To verify the properties of nuclear library, we compared computational results with experimental value. These results can be used for dose evaluation technology in planning of the shielding of large particle accelerator.

Development of an augmented reality based underground facility management system using BIM information (BIM을 활용한 증강현실 기반 지하시설물 관리 시스템 개발에 관한 연구)

  • Shin, Jaeseop;An, Songkang;Song, Jeongwoog
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.525-538
    • /
    • 2022
  • In Korea, safety accidents are continuously occurring due to the aging of underground facilities and lack of systematic management. Moreover, although the underground space is continuously being developed, the current status information is not clearly recorded and managed, so there is a limit to the systematic management of underground facilities. Therefore, this study developed an augmented reality-based system that can effectively maintain and manage underground facilities that are difficult to manage because they are located underground. In order to develop an augmented reality-based underground facility management system, three essential requirements, 'precise localization', 'use of BIM information', and 'ensure usability' were derived and reflected in the system. By utilizing Broadcast-RTK, the positional precision was secured to cm level, and the configuration and attribute information of the BIM was converted into the IFC format to construct a system that could be implemented in augmented reality. It developed an application that can optimize usability. Finally, through simulation, the configuration and attribute information of structures and mechanical systems constituting underground facilities were implemented in augmented reality. In addition, it was confirmed that the accurate and highly consistent augmented reality system works even in harsh environment (near high-rise building).

A study on the characteristics of Vibration Reduction Type Disk bearing in Station of Rapid Transit Railway (역사 내 진동저감형 디스크 받침 특성에 관한 연구)

  • Park, Tae-Hyun;Park, Hean-Sang;Kim, Ho-Bae;Choi, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.297-302
    • /
    • 2011
  • Railway construction in the random vibration natural phenomena, as well as a relatively regular train loads for dynamic loads, such as a usability and safety should be ensured. Vibration due to train loads and seismic vibrations caused by wind compared to the typically very small in size, rather than the safety of the structure affects the usability. Recently in the downtown area, ground and underground facilities, such as a permanent facility that may cause excessive vibration increases, associated with the construction of these transportation facilities on ground vibrations of structures has been increasing concern and complaint. More recently, high-speed train vibration and noise due to furnace is increasing. In order to solve this problem, such as soundproof considering several feet, but by applying the vibration and noise reduction measures insufficient for the study is Free. In this study, track structure, track, and the inside of the building to support the system, the different forms of neurological history and share about the history cheonanahsan high-speed rail, if passed by the bus stop on the train loads of noise, and the history of interior noise and vibration measurement / analysis of measurement results to assess the relative comparison with the relevant provisions were reviewed. Based on this history, future plans for the design of the bridge to reflect the results of a study is intended to provide information. Waiting for the analysis of vibration and noise reduction, cheonanahsan history passed quietly in the train, on average, appeared to 67.53dB and 65.41dB nervous week on average, were measured with the history. Nervous week waiting room of history and the history cheonanahsan radically different shapes and sizes, so a direct comparison is impossible, but the vibration caused by the disc on the base of the polyurethane elastomer disk is not supported by GERB SYSTEM Waiting more effective in reducing the noise level considered in The main materials for railway and for the localization will help to ensure affordability is considered.

  • PDF

Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry (이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법)

  • Kim, Ho-Sung;Kim, Tae-Hyung;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

A Study on the Body Size of High School Girls for Improvement of Educational Environment (with $17\sim19$ years) (교육환경 개선을 위한 여자 고등학생 (17세$\sim$19세)의 신체치수에 관한 연구)

  • Leem, Young-Moon;Bang, Hey-Kyong;Hwang, Young-Seob
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • In general, it is fact that most educational institutions have lots of problems about shift of education facility and equipment because of insufficient budget. However, most high school girls live a lot of period in the school and most of them wear student uniform. Thus, it is necessary that educational environment has to be improved by actual body size of high school girls. The main objective of this study is to provide numerical guideline for the improvement of educational environment about high school girls ($17\sim19$ years) through comparison and analysis on physical standard of nation (report published in 1997). The sample for this work chosen from data which were collected and measured by Size Korea during two years $(2003\sim2004)$. In order to analyze feature of the somatotype of high school girls, analysis was performed about 734 subjects on 25 body parts such as height (7 parts), width (4 parts), thickness (4 parts), circumference (5 parts), length (4 parts) and body weight. For the specific comparison on somatotype, $R\ddot{o}hrer$ index and Mollison's comparison graph were used. The result of this study can be utilized in various fields such as design of classroom, student uniforms, facilities and equipments for education, etc.

A Study on Process Design of Hot Oil Flushing System Using Oil-Nitrogen Gas Mixing Fluid (오일-질소가스 혼합유체를 이용한 고온 오일플러싱 시스템 공정설계에 관한 연구)

  • Lee, Yoon-Ho;Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.541-548
    • /
    • 2017
  • A theoretical study on gas-liquid two-phase flow flushing systemnitrogen gas to the oil used for existing flushing equipment was conducted on the basis of ISO code so as to improve performance of existing high-temperature oil flushing equipment used in ocean plant facility drying field. For study, we analyzed process simulation results mixed fluid mixing ratio, temperature, Reynolds number and liquid hold up affectcleaning performance after designing oil-nitrogen gas mixture flushing system process. As a result, as the volume flow rate of mixed fluid increases with the tube diameter the volume fraction of the gas phase constant, the liquid fraction difference value at the inlet and outlet of horizontal hydraulic piping increases. It was found that the phase distribution between oil and nitrogen gas bubbles varies depending on the position the pipe lengthdirection. This change in phase distribution is expected to have a significant impact on the clean performance of an oil-nitrogen gas mixture flushing system.

A Gap-acceptance Model Considering Driver's Propensity at Uncontrolled Intersection (운전자 특성 등을 고려한 무통제교차로의 간격수락 모델)

  • Jang, Jeong-Ah;Lee, Jung-Woo;Choi, Kee-Choo
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.6
    • /
    • pp.71-80
    • /
    • 2008
  • Typically uncontrolled intersections are characterized by the absence of signal, stop and yield sign, and by very light traffic volume. In this study, a gap acceptance model for such uncontrolled intersections has been modeled. The motivation is to identify the behavior of drivers so that the traffic flow phenomena can be easily understood. For this, actual traffic survey was accomplished at intersections in Suwon and the data have been fed into modeling process. The logit model was used and the results showed that total delay experienced by drivers, turning right movement, age, sex, and the existence of passenger affected gap acceptance. For example, male drivers, with experiencing longer delay and having passenger(s) with them, accepted shorter gaps. These identified characteristics regarding gap acceptance could be used for facility design and/or safety oriented traffic information dissemination near uncontrolled intersections.

Spatial Structure Analysis and Post Occupancy Evaluation of Jungja(Pavilion) Shelter for Rural Village Regeneration - On the Jungja Shelter in Gimcheom city and Kyeongsan city - (농촌마을 재생을 위한 정자쉼터 공간구조분석과 이용 후 평가 - 경산권, 김천권 정자쉼터를 대상으로 -)

  • Koo, Min-Ah;Eom, Boong-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.99-110
    • /
    • 2017
  • This study is to analyze the spatial structure and POE of Jungja(pavilion) shelter for rural village regeneration. 14 Jungja shelter space at rural villages in Gyungbuk province, were investigated. An interview questionnaire was conducted for total 139 residents as POE. The use behavior and satisfaction for Jungja shelter space, were investigated. The statistical analysis were mean of satisfactions, reliability, factor analysis, and multiple regression analysis. The results and discussions can be objective data for rural village regeneration. In satisfaction level, 'Continuous use intention'(3.99), 'Well-suited approach'(3.87), and 'Helpful in resident living'(3.84) were shown to be high points of agreement in 5 point Likert type scale. But, the mean points were low as 2.01 in 'Surrounding landscape', 'Creation of green areas'(3.22), and 'Traffic safety'(3.22), respectively. Within use satisfaction, 5 factors were categorized, 'Use', 'Safety', 'Facility', 'Management' and 'Users'. By the result of multiple regression analysis, variables of 'Continuous use', 'Convenient location', and 'Image improvement', were shown to be main affecting variables to overall satisfaction. Furthermore, in spatial structure analysis, 4 types were categorized with the aspect of landform, roads, and location in village. The levels of satisfaction were shown to be high in village type of semi-open, road type of circular, and location type of center/back. Conclusively, these findings could be utilized as basic data and useful tool of space-structural satisfaction analytic method, and for each stage of planning/design and remodeling for rural village regeneration.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.