Acknowledgement
이 과제는 부산대학교기본연구지원사업(2년)에 의하여 연구되었음.
References
- Anajafi, H., Poursadr, K., Roohi, M., and Santini-Bell, E. (2020), Effectiveness of Seismic Isolation for Long-period Structures Subject to Far-field and Near-field Excitations, F-rontiers in Built Environment, 6, 24. https://doi.org/10.3389/fubil.2020.00024
- Ariga, T., Kanno, Y., and Takewaki, I. (2006), Resonant Behaviour of Base-isolated High-Rise Buildings under Long-period Ground Motions, The Structural Design of Tall and Special Buildings, 15(3), 325-338 https://doi.org/10.1002/tal.298
- Hall, J. H., Heaton, T. H., Halling, M. W., and Wald, D. J. (1995), Near-source Ground Motion and its Effect on Fl-exible Buildings, Earthquake Spectra, EERI, 11(4), 569-605 https://doi.org/10.1193/1.1585828
- Heaton, T. H., Hall, J. H., Wald, D. J., and Halling, M. W. (1995), Response of High-rise and Base-isolated Buildin-gs to a Hypothetical MW 7.0 Blind Thrust Earthquake, Sc-ience, 2667(5195), 206-211.
- Iemura, H., Taghikhany, T., and Jain, S. K. (2007), Optim-um Design of Resilient Sliding Isolation System for Seismi-c Protection of Equipment, Bulletin of Earthquake Enginee-ring, 5(1), 85-103. https://doi.org/10.1007/s10518-006-9010-5
- International Code Council (ICC-ES AC156). (2010), Acceptance Criteria for Seismic Certification by Shake-table Tes-ting of Nonstructural Components, USA.
- International Electrotechnical Commission (IEC 60068-2-57: 2013). (2013), Environmental Testing - Part 2-57: Tests - Test Ff: Vibration-Time-history and Sine-beat Method
- Irikura, K., Kamae, K., and Kawabe, H. (2004), Importanc-e of Prediction of Long-period Ground Motion during Larg-e Earthquakes, Annual Conference of the Seismological So-ciety of Japan, Poster Session, Fukuoka.
- Ismail, M., Rodellar, J., and Ikhouane, F. (2009), An Inno-vative Isolation Bearing for Motion-sensitive Equipment, Jo-urnal of Sound and Vibration, JSV, 326(3-5), 503-521. https://doi.org/10.1016/j.jsv.2009.06.022
- Jangid, R. S., and Datta, T. K. (1994), Non-linear Respon-se of Torsionally Coupled Base Isolated Structure, Journal of Structural Engineering, JSEG, 120(1), 35-44.
- Kim, K.Y., Kim, T.H., and Lee, T.H. (2002), Experimental Study of the Small Scaled Base-isolated Steel Structure, Jo-urnal of Architectural Institute of Korea - Structure & Con-struction, AIK, 22(02)
- Kobayashi, M. (2014), Experience of infrastructure damage caused by the Great East Japan Earthquake and Countermeasures again-st Future Disasters, IEEE Communications Magazine, 52(3), 23-29. https://doi.org/10.1109/MCOM.2014.6766080
- Korea Authority of Land & Infrastructure Safety. (2019), Seismic Performance Evaluation of Existing Structures (Buildings), Korea Authority of Land & Infrastructure Safety, Jinju, Korea.
- Li, H. N., and Wu, X. X. (2006), Limitations of Height-to-width Ratio for Base-isolated Buildings under Earthquake, T-he Structural Design of Tall and Special Buildings, 15(3), 277-287. https://doi.org/10.1002/tal.295
- Lopez Garcia, D., and Soong, T. T. (2003(a)), Sliding Fragili-ty of Block-Type Nonstructural Components. Part 1: Unres-trained Components, Earthquake Engineering and Structura-l Dynamics, 32(1), 111-129. https://doi.org/10.1002/eqe.217
- Lopez Garcia, D., and Soong, T. T. (2003(b)), Sliding Fragili-ty of Block-Type Nonstructural Components. Part 2: Restra-ined Components, Earthquake Engineering and Structural Dynamics, 32(1), 131-149. https://doi.org/10.1002/eqe.218
- Ministry of Land, Infrastructure and Transport. (2019), Seismic Design Standard for Buildings (KDS 41 17 00:2019), Ministry of Land, Infrastructure and Transport, Sejong, Korea.
- Miranda E., Mosqueda G., Retamales R. and Pekcan G. (2012), Performance of Nonstructural Components during the 27 February 2010 Chile Earthquake, Earthquake Spectra, EERI, 28(1), 453-471. https://doi.org/10.1193/1.4000032
- Morales, C. A. (2003), Transmissibility Concept to Control Base Motion in Isolated Structures, Engineering Structures, 25(10), 1325-1331. https://doi.org/10.1016/S0141-0296(03)00084-1
- National Radio Research Agency (NRRA). (2016), Seismic Test Method for Telecommunication Facilities, Naju, Korea.
- Naeim, F., and Kelly, J. M. (1999), Design of Seismic Isol-ated Structures, John Wiley & Sons, Inc, 1-23.
- NEBS Requirements: Pysical Protection (GR-63-CORE). (2016), Telcordia Technologies, Inc., Network Equipment Build-ing System Generic Requirements 63 Core, Issue 3, New Jersey, USA.
- Oh, S.H., Choi, K.Y., Ryu, H.S., and Kim, Y.J. (2018), An Experiment Study on Verification for the Performance of S-eismic Retrofit System Using of Dual Frame with Different Eigenperiod, Journal of the Korea Institute for Structural Maintenance and Inspection, KSMI, 22(5), 91-100 https://doi.org/10.11112/JKSMI.2018.22.5.091
- Saito, T. (2016), Response of High-rise Building under Lon-g Period Earthquake Ground Motions, International Journal of Structural and Civil Engineering Research, 5(4), 308-314.