• Title/Summary/Keyword: Facility monitoring

Search Result 577, Processing Time 0.029 seconds

A Study on the Facility Establishment for Nature Environment Conservation and its Utilization (자연환경보전·이용시설의 조성방안에 관한 기초적 연구)

  • Lee, Dong Kun;Choi, Jae Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.3
    • /
    • pp.40-49
    • /
    • 2002
  • The objective of this research is to suggest the appropriate natural environment conservation facility management plan in Korea through development of the proper definition and categorization. Bearing the above objective, this study employs the comparison and analysis between domestic and international case studies. Furthermore, several survey methods have been adopted as check-lists for the evaluation of the sample sites and quantitative interviews with government officials and visitors to investigate their perspectives. On the consequence, firstly it was found that considering ecological types and objectives, the proper applicability of natural environment conservation facility could be disaggregated into three types of eco-park, eco-experience and education, and eco-observation facility. Secondly, based on the interview results, the necessity of provision of the natural environment conservation facilities was strongly found among the governmental officials and the residents groups who also expect the expansion of the facilities. Lastly, it appears necessary that the expansion of supporting projects and programs on the natural environment conservation facilities, the estimation and provision of the appropriate funding for monitoring, management and operation, the arrangement of resident experts, and activation of the nature environment education programs.

Guidelines for the Establishment and Vitalization Scheme on Facility of Nature Environmental Conservation and its Utilization (자연환경보전·이용시설 가이드라인 및 활성화방안)

  • Choi, Jaeyong;Park, Sohyun;Lee, Dong Kun;Shin, Kyungjoon;Hong, Taesik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.4
    • /
    • pp.36-51
    • /
    • 2006
  • Although the demand and necessity for the facilities of nature environmental conservation and its utilization have been increased recently, the local governments has been experiencing difficulties to launch the facilities since there are no confirmed principles or guidelines for the direction of the facility and distinctions from the ordinary parks. In this regard, the aim of this paper is to provide the overall framework for establishing the facility by equipping checklists from planning to operational stage. The stages are disengaged into 5 steps of siting feasibility, planning, preliminary environmental assessment and environmental impact assessment, design, construction, and operation. This paper also include the recommendations to vitalize the existing facilities, of which expansion of educational program development; utilization of various manpower; provision of appropriate settings; strengthened monitoring; and increased public relations. Furthermore, it is suggested to consider the strengthened local characteristics, reviewing management plan at the stage of applying a new facility establishment to the concerned authority, fostering experts, and expansion of the facilities through restoration of environmentally damaged areas for a new facility.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

A Study on the Design of SUS Module for SITES Development (부지환경종합관리시스뎀 개발용 SEMS모듈 설계에 관한 연구)

  • Ko Do-Young;Park Se-Moon;Kim Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.4
    • /
    • pp.263-269
    • /
    • 2004
  • During the last two years, Site Information and Total Environmental database management System (SITES) ver. 1.0 has been developed for the systematic SITES Database Module (SDM), which includes site information, facility information and environmental information. The SITES includes the module for site environmental monitoring system and safety assessment (M&A) system for the nuclear facility. SITES is expected to be an effective system for the radioactive waste disposal management facility. Currently, SITES ver.2.0 is under development after the SITES ver.1.0 that is focused on the M&A system. The main purpose of this paper is to introduce and try to account for the major development in the concept of SEMS sub-module of the M&A module. The SEMS is purposed of development of the program for real time environmental monitoring, prediction, and automatic alarm system using SITES Database and related information.

  • PDF

Improvement in Underground Facilities Management Process ; Focused on the District Heating Facility (지하시설물 유지관리 업무프로세스 개선 방향에 관한 연구 ; 지역난방 시설을 중심으로)

  • Kim, Jung-Hoon;Lim, Si-Yeong
    • Spatial Information Research
    • /
    • v.17 no.3
    • /
    • pp.319-328
    • /
    • 2009
  • The growth of sensor and wireless communication technology enable us to monitor the status of things in real-time. There are many attempts to apply the real-time monitoring in various fields. Especially, the real-time monitoring in facility management fields has attracted much attentions recently. But it is difficult to apply recent technologies including sensor, wireless communication and Geospatial information technologies, etc, to the real situation directly. One of the reasons is that facility managers who are familiar with existing processes may resist the change induced by new technologies. So it is necessary to close the gap between new technologies and existing processes by improving the existing processes prior to putting them in the field. In this paper, we suggest the management process improvement focused on the district heating facilities.

  • PDF

Study on the Liquid Rocket Engine Health Monitoring and Emergency Protection System (액체로켓엔진 상태진단/비상보호시스템 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.178-182
    • /
    • 2007
  • This paper reviews on the LRE health monitoring and emergency protection system to protect test object engine system and engine test facility, in case of various fault occurrence at LRE testing. General composition and major technical consideration of LRE health monitoring system and emergency protection system are reviewed. Moreover, some application of LRE health monitoring/emergency protection system to development test of major LRE component such as turbopump testing, gas generator and combustion chamber test are reviewed.

  • PDF

Design of a Monitoring System for Controlling the Wet Station Equipment (Wet Station 장비를 제어하기 위한 모니터링 시스템의 설계)

  • Im, Seong-Rak;Han, Gwang-Rok;Choe, Yong-Yeop
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.5
    • /
    • pp.1385-1392
    • /
    • 1999
  • This paper describes the design of the monitoring system for monitoring the current status and indirect controlling of the Wet Station Equipment which is used for cleaning the wafer. Most of the conventional monitoring system depend on the special hardware and software. Basic design goal of monitoring system is provide the convenience for the use and the portability for the system. In order for the system to fulfil its requirements, it was designed using GUI (Graphical User Interface) facility based on the windows NT environment of IBM PC compatible and EtherNet board based on the TCP/IP protocol.

  • PDF

A STUDY ON DEVELOPMENT OF MONITORING & ASSESSMENT MODULE FOR SITES

  • Park, Se-Moon;Yoon, Bong-Yo;Kim, Dae-Jung;Park, Joo-Wan;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.575-584
    • /
    • 2006
  • As the development of total management systems for sites along with site environmental information is becoming standard, the system known as the Site Information and Total Environmental database management System (SITES) has been developed over the last two years. The first result was a database management system for storing data obtained from facilities, and a site characterization in addition to an environmental assessment of a site. The SITES database is designed to be effective and practical for use with facility management and safety assessment in relation to Geographic Information Systems. SITES is a total management program, which includes its database, its data analysis system required for site characterization, a safety assessment modeling system and an environment monitoring system. It can contribute to the institutional management of the facility and to its safety reassessment. SITES is composed of two main modules: the SITES Database module (SDM) and the Monitoring & Assessment (M&A) module [1]. The M&A module is subdivided into two sub-modules: the Safety Assessment System (SAS) and the Site Environmental Monitoring System (SEMS). SAS controls the data (input and output) from the SITES DB for the site safety assessment, whereas SEMS controls the data obtained from the records of the measuring sensors and facilities. The on-line site and environmental monitoring data is managed in SEMS. The present paper introduces the procedure and function of the M&A modules.

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Preparation and Management of the Input Data for the Safety Assessment of Low- and Intermediate-level Radioactive Waste Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설 안전성평가를 위한 입력데이터 설정 및 관리에 대한 고찰)

  • Park, Jin Beak;Kim, Hyun-Joo;Lee, Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.345-361
    • /
    • 2014
  • The systematic quality assurance activities on documents of the safety assessment are required for the safety case of the low- and intermediate-level radioactive waste disposal facility. In this paper, quality assurance system focused on the input data including the site characterization, groundwater flow, system design and monitoring are prepared and discussed. Rule for the input data selection is suggested and applied for the safety assessment which is based on the in-situ/experiment observations, final facility design and waste pileup plan, engineered barrier, field monitoring, recent biosphere, and radionuclide inventory. The reduction of data uncertainty will be expected to contribute to the safety of disposal facility further.