• Title/Summary/Keyword: Facility Noise

Search Result 247, Processing Time 0.028 seconds

Next Generation Smart-City Facility Platform and Digital Chain (차세대 스마트도시 시설물의 플랫폼 정의와 디지털 체인)

  • Yang, Seung-Won;Kim, Jin-Wooung;Kim, Sung-Ah
    • Journal of KIBIM
    • /
    • v.10 no.4
    • /
    • pp.11-21
    • /
    • 2020
  • With increasing interest and research on smart cities, there is also an increasing number of studies on urban facilities that can be built within smart cities. According to these studies, smart cities' urban facilities are likely to become high value-added industries. However, the concept of smart city is not clear because it involves various fields. Therefore, in this study, the definition of Next-Generation(N.G) Smart City Facilities with Digital Twin and Digital Chain is carried out through a multidisciplinary approach. Based on this, Next-Generation Smart City Facilities will be divided into High Value-Added Products and Big Data Platforms. Subsequently, the definition of the Digital Chain containing the data flow of the entire process built through the construction of the Digital Twin proceeds. The definitions derived are applied to the Next-Generation Noise Barrier Tunnel to ensure that data is exchanged at the Digital Twin stage, and to review the proposed configuration of the Digital Chain and Data Flow in this study. The platform definition and Digital Chain of Next-Generation Smart City Facilities proposed in this study suggest that it can affect not only the aspects of data management that are currently in the spotlight, but also the manufacturing industry as a whole.

Parameter Design of an ER Panel for Noise Reduction using Taguchi Method (다구찌법을 이용한 소음저감용 ER 패널의 파라미터 설계)

  • 윤영민;김재환;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.638-642
    • /
    • 2003
  • This paper presents a parameter design of an Electrorheological(ER) panel for noise reduction using Taguchi method. Taguchi method is a robust design method that determines control parameters in the presence of noise effect. Host structure thickness, spacer thickness, base oil viscosity and the weight ratio of ER particles are chosen for the control factors. A test setup in an SAE J1400 facility is used to analyze the sound transmission loss. The sensitivity of each factor with signal-to-noise(S/N) ratio and analysis of variance are investigated. The analysis results show that the weight ratio of ER particle and base oil viscosity of the ER fluid mostly affects the noise reduction in the presence of electric field. Based on the Taguchi method, an optimal configuration was designed and comparison is made with experimental result fer the verification.

  • PDF

A Study on the Performance Improvement of Medium Speed Diesel Engine Exhaust Silencer in the Low-frequency Range Using Array Resonators (공명기 배열을 이용한 중속 디젤엔진 배기 소음기의 저주파수 대역 성능 개선 연구)

  • Kim, Young-Hyun;Joo, Won-Ho;Bae, Jong-Gug
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.693-698
    • /
    • 2009
  • Various acoustic tests were carried out to investigate the acoustic performance of diesel engine exhaust silencers. In order to consider flow effects, the test facility was set up composed of fan, duct and silencer. Using the test facility, insertion loss tests were carried out to improve the acoustic performance in the low-frequency ranges. Through a series of tests, it was found out that the array resonators having multi-perforated holes inside the exhaust silencer, might be very effective in the low frequency range. Consequently, the hybrid-type silencer which is the combination of reflective silencer with array resonators and conventional absorptive silencer, was proposed and its high performance in the low-frequency range was also verified.

A evaluation and countermeasure for blast-induced vibration of micro electronic production facility based on experimental method (실험적 방법에 의한 발파작업으로 기인하는 인접 초정밀 생산장비 FAB에 미치는 진동 영향성 평가 및 제어대책)

  • Son, Sung-Wan;Park, Sang-Gon;Lee, Hong-Ki;Chun, Jong-Kun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.875-878
    • /
    • 2006
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function, therefore, it is very important to predict precisely vibration environment of microelectronics production facility due to adjacent blast work. However, it is not easy to evaluate a quantitative vibration response of structure due blast because it can be determined by the characteristics of vibration sources, propagation through rock and soil and dynamic properties of building. In this paper, vibration influence evaluation of micro-electronic Production building induced from adjacent blast activity was performed by real measurement data obtained on ground and structure at same time. And blast vibration allowable limit on ground was supposed by measurement data analysis in order to avoid operation error of precision equipments

  • PDF

An Experimental Study on the Optimistic Recognition Level of Public Address System as a Soundscape Application Facility (사운드스케이프 적용을 위한 옥외 P.A. 시스템 적정 인지레벨에 관한 실험적 연구)

  • Song, Min-Jeong;Jang, Gil-Soo;Shin, Hoon;Shin, Young-Gyu;Lee, Tai-Kang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.726-729
    • /
    • 2006
  • As a active soundscape facility, P.A. system is a useful instrument to give place identity and vitality by letting out music, environmental music, bird singing sound etc. In this study, to know the optimistic distance and sound level range of introducing sound, sound levels due to distance were measured and subject responses were checked by questionnaire. Levels from 64dB to 71dB are recommended by subjects. And the optimistic level of introducing level is related with level variance of sound source. The results of this study could used for street furniture location design and P.A. system output level.

  • PDF

A Noise Control of a Floating, Production, Storage and Offloading (FPSO) (부유식 석유생산/저장/하역 선박(FPSO)의 소음예측 및 저감)

  • Kim, Dong-Hae;Ko, Kyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.550-553
    • /
    • 2004
  • Recently, the demand for the Floating, Production, Storage, and Offloading facility (FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The 36,8000 DWT class FPSO was built in Hyundai Heavy Industries and will be installed in Offshore Angola. She dose not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise sources are contributing to the cabin noise of the accommodation are classified into three classes such as the machinery in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is severer than that of the cargo ship and acceptable noise limit of cabin is specified as 45 dB(A). This paper describes the procedure of noise analysis, the countermeasures of noise control, and the measurement results of the quay trial. In order to minimize the noise levels, careful attention have to be paid by the special committee of experts from the initial design stage to the delivery. Proper countermeasures, considering the characteristics of sources and receiver spaces, were applied from the noise prediction and various experiment results. Finally, this ship was successfully delivered with excellent noise properties. The technology to minimize the noise levels for FPSO has been established throughout the construction of this ship.

  • PDF

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Preliminary Design of Test Facility for 75-tonf-Class Liquid Rocket Engine Combustor (75톤급 액체로켓엔진 연소기 시험설비 기본설계)

  • Lim, Byoung-Jik;Seo, Seong-Hyeon;Kim, Mun-Ki;Kang, Dong-Hyuk;Han, Yeong-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.84-91
    • /
    • 2010
  • For the successful development of 75-tonf-class liquid rocket engine, a plenty of tests on each engine component have to be performed and this is equally true for a combustor. However the test facility which is in operation at Korea Aerospace Research Institute lacks its capacity to perform fire tests of a 75 tonf class combustor at its nominal thrust. Since the test facility has to be ready prior to the start of development tests, it is very urgent to establish the test facility. The preliminary design of a test facility for a 75 tonf class combustor which was performed according to such a necessity is described in the paper.

A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure (방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

Valve induced noise and vibration evaluation procedure for process piping of offshore production facility (Offshore 선 Process 배관계의 밸브 소음/진동 평가 절차)

  • Lee, JooHun;Choi, ChoongYoung;Kim, JaeHong;Kwun, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.201-204
    • /
    • 2014
  • Recent year, the vibration induced fatigue and noise of piping work become critical in offshore hydrocarbon production facilities with increasing requests by major oil company. In this paper, the risk base piping vibration induced fatigue assessment of NORSOK L-002 standard and UK Energy Institute guideline have been introduced with real project application practice. Also the piping breakout noise evaluation by flow restriction devices of compressible and in-compressible flow are reviewed with its practical application on real project.

  • PDF