• Title/Summary/Keyword: Facility Management Standard

Search Result 271, Processing Time 0.027 seconds

Determination of Process Capability Index considering Inspection Precision (검사정밀도를 고려한 공정능력지수의 결정)

  • 송서일;조영찬
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.4
    • /
    • pp.114-122
    • /
    • 1999
  • As the rapid growth of Industrial society, many enterprises are inclined to ppm management from the traditional$3\'{o}$ management method. Therefore it is need to extend process capability index for guarantee of quality assurance level to ppm unit. Thus, in this paper, using the probability of standard normal distribution from $ 3\'{o}; to; 6\'{o}$ which was developed by Song(1997), the capability index which is proposed considers the numbers of inspection facility and quality assurance level. Also, quality assurance level is determined by considering the precision of inspection when one and two sided specification limits are given for the probability which is out of the specification limit.

  • PDF

A Study on the Collecting Method of Reliability Database for Gas Facilities (가스설비의 신뢰도데이터 수집방법에 관한 연구)

  • Rhie, Kwang-Won;Yoon, Ik-Keun;Han, Sang-Tae;Oh, Sin-Kyu;Kim, Tae-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2008
  • The safety assessment for facility industry is now being periodically performed. For the purpose of scientific safety management, QRA(Quantitative Risk Assessment) is also being performed, and reliability data of the facilities is essential to perform the assessment. Generally, the existing safety assessment is performed by using the values announced in other industry processes, which result in the drop of reliability. In order to solve this problem, there is an urgent need to establish reliability database for the facilities. The most appropriate method is to perform a direct reliability analysis towards the facilities undergoing safety assessment. In this study, in compliance with the assessment method and procedure of OREDA-2002 handbook, the facility reliability data are collected, which include the calendar time and operational time in terms of different facility items, the number of failures in terms of different failure mode, the mean, standard deviation, lower limit and upper limit of failure rate, and the failure rate. And the data process method for this special occasion is also proposed when the number of failure is 0.

Alternatives for Optimum Installation of Rural Sewage Treatment Facilities in Chungchongnam-do Province (충청남도 마을하수처리시설의 최적 설치방안)

  • Yi, Sang-Jin;Jung, Jong-Gwan;Lim, Bong-Su;Huh, Jae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.462-472
    • /
    • 2005
  • This study was carried out to suggest the plans for installation of rural sewage treatment facilities through the analysis of these facilities installed in Chungchongnam-do Province. About 5% of all installation was carried out by the department of wastewater and related environment problems and the other case was carried out by the department of construction or residence. In wastewater caused by 250 and 300 persons, facilities capacity do not exceed about $50m^3/d$, caused by 2,500 and 3,000 persons, $500m^3/d$. Advanced sewage treatment process were first needed in the discharge area where affected the water environment greatly. However, in carrying out the water quality pollutant of the total amount management system in the other areas, they should be driven only over the scale of pollutant quota object facilities standard. Rural sewage must be included in the special accounts according to the regulations of local government, and sewage treatment cost should be collected to manage. Installation type uses integrating joint treatment method in case the distance among villages is short or one treatment facility independently.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

- A Study on Quality Category Considering Safety, Maturity and Complexity in Nuclear Facility - (원자력시설에서 안전성, 성숙도, 복잡성을 고려한 품질등급에 관한 연구)

  • Ji Chul Goo;Kwon Hyuk Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.277-287
    • /
    • 2004
  • This study presents a method of quality category classification by safety, maturity, complexity, and what types and extent of controls and verifications are applied to specific products and services during the various stages of a nuclear facility life cycle. All products, services and processes have various controls and verifications built in to ensure they perform their functions satisfactorily. The highest grade should require the most stringent application of the quality assurance requirements ; while, the lowest grade should require the least stringent. When products or services are modified, the assigned grade of quality assurance requirements could become more stringent or less stringent depending on the significance in nuclear safety. Applying QA program always costs money, and they should be applied and focused to the extent where necessary and not applied or applied to a lesser degree for less important activities. An efficient QA program should be developed to satisfy the necessary requirements and to ensure the required confidence in quality, but without unnecessary stipulations. Not all the requirements of QA standard must be applied identically to all products and services which are to be provided.

  • PDF

Airborne Fine Particle Measurement Data Analysis and Statistical Significance Analysis (공기중 미세입자 측정 데이터 분석 및 통계 유의차 분석)

  • Sung Jun An;Moon Suk Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 2023
  • Most of the production process is performed in a cleanroom in the case of facilities that produce semiconductor chips or display panels. Therefore, environmental management of cleanrooms is very important for product yield and quality control. Among them, airborne particles are a representative management item enough to be the standard for the actual cleanroom rating, and it is a part of the Fab or Facility monitoring system, and the sequential particle monitoring system is mainly used. However, this method has a problem in that measurement efficiency decreases as the length of the sampling tube increases. In addition, a statistically significant test of deterioration in efficiency has rarely been performed. Therefore, in this study, the statistically significant test between the number of particles measured by InSitu and the number of particles measured for each sampling tube ends(Remote). Through this, the efficiency degradation problem of the sequential particle monitoring system was confirmed by a statistical method.

  • PDF

Economic implications of optimal operating conditions in a full-scale continuous intermittent cycle extended aeration system (ICEAS) (실규모 연속유입간헐폭기 공정(ICEAS)에서 최적운전조건이 경제성에 미치는 영향)

  • Yong-jae Jeong;Yun-Seong Choi;Seung-Hwan Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.1
    • /
    • pp.29-38
    • /
    • 2024
  • Wastewater management is increasingly emphasizing economic and environmental sustainability. Traditional methods in sewage treatment plants have significant implications for the environment and the economy due to power and chemical consumption, and sludge generation. To address these challenges, a study was conducted to develop the Intermittent Cycle Extended Aeration System (ICEAS). This approach was implemented as the primary technique in a full-scale wastewater treatment facility, utilizing key operational factors within the standard Sequencing Batch Reactor (SBR) process. The optimal operational approach, identified in this study, was put into practice at the research facility from January 2020 to December 2022. By implementing management strategies within the biological reactor, it was shown that maintaining and reducing chemical quantities, sludge generation, power consumption, and related costs could yield economic benefits. Moreover, adapting operations to influent characteristics and seasonal conditions allowed for efficient blower operation, reducing unnecessary electricity consumption and ensuring proper dissolved oxygen levels. Despite annual increases in influent flow rate and concentration, this study demonstrated the ability to maintain and reduce sludge production, electricity consumption, and chemical usage. Additionally, systematic responses to emergencies and abnormal situations significantly contributed to economic, technical, and environmental benefits.

Establishment on Management Plan of Environmental Noise with Noise Map (소음지도를 활용한 환경소음 관리계획 수립)

  • Sun, Hyosung
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.123-131
    • /
    • 2011
  • The objective of this study is to prepare the effective management plan of environmental noise with a noise map, and the guideline on the management plan of environmental noise was suggested through the review of existing application examples. The management plan of environmental noise with a noise map includes the practical contents in the stages of subdivision of management areas, establishment of reduction measures, opinion collection, post investigation, and reformulation of management plan. First, the classification of management regions is performed considering the excess degree of noise standard and the facility type in the phase of subdivision of management areas. Second, the optimal management plan is established through the investigation of regional characteristics and various noise reduction measures in the phase of establishment of reduction measures, which includes the examination of noise reduction effects with a noise map and the budget planning with the costing of noise reduction measures. Third, the opinion survey with a local resident and a expert is carried out in order to prove the validity of the management plan in the phase of opinion collection, and the management plan is modified with gathered opinions. Fourth, the post examination plan with noise measurement is performed in order to verify the real effect of noise reduction measures according to the management plan in the phase of post investigation. Finally, the amendment of the management plan as well as the improvement of a noise map is carried out at a regular cycle in the phase of reformulation of management plan.

A STUDY ON DEVELOPMENT OF MONITORING & ASSESSMENT MODULE FOR SITES

  • Park, Se-Moon;Yoon, Bong-Yo;Kim, Dae-Jung;Park, Joo-Wan;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.575-584
    • /
    • 2006
  • As the development of total management systems for sites along with site environmental information is becoming standard, the system known as the Site Information and Total Environmental database management System (SITES) has been developed over the last two years. The first result was a database management system for storing data obtained from facilities, and a site characterization in addition to an environmental assessment of a site. The SITES database is designed to be effective and practical for use with facility management and safety assessment in relation to Geographic Information Systems. SITES is a total management program, which includes its database, its data analysis system required for site characterization, a safety assessment modeling system and an environment monitoring system. It can contribute to the institutional management of the facility and to its safety reassessment. SITES is composed of two main modules: the SITES Database module (SDM) and the Monitoring & Assessment (M&A) module [1]. The M&A module is subdivided into two sub-modules: the Safety Assessment System (SAS) and the Site Environmental Monitoring System (SEMS). SAS controls the data (input and output) from the SITES DB for the site safety assessment, whereas SEMS controls the data obtained from the records of the measuring sensors and facilities. The on-line site and environmental monitoring data is managed in SEMS. The present paper introduces the procedure and function of the M&A modules.

A Study of Preference and Satisfaction Factors between Senior Specialized Hospitals and Senior Care Facilities for Senior Stroke Patients (뇌졸중 환자들의 노인전문병원 및 노인요양시설 선택요인과 이용만족도)

  • Ahn, Kwang-Ho;Sohn, Tae-Yong;Oh, Hyohn-Joo
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.1
    • /
    • pp.147-158
    • /
    • 2011
  • This study compares the degree of satisfaction and the causes of selecting facilities for stroke patients in the senior specialized hospitals and other senior care facilities. The research results are followed. First, The patients who held the level of senior long-term care used senior specialized hospitals, while the patients who had the level of 2 or 3 degree used senior care facilities. The patients helped by cooperative care service used senior care facilities, and the patients helped by private service or family service used senior specialized hospitals. Second, The patients in senior specialized hospitals had affirmative attitude for their service system, while the patients in senior care facilities preferred their various service systems. In the satisfaction of the facilities, the patients in senior care facilities felt more satisfaction to staff, environment, service, and other factors than the patients in hospitals did. Third, in the result of logistic analysis, the patients had an affirmative attitude in case that they had spouse, experience of senior specialized hospitals or senior care facilities, without senior long-term care insurance. They also valued the service standard and the staff quality. As this study points out, the overall preference is higher in the senior care facilities. So, the stroke patients recognized the new role between the hospitals and the facilities after the establishment of long-term senior medicare system. This research had some limitation for the research areas and numbers. So the data analysis for the types of facility and the responses may not be generalized. However, the standard of choosing facility and satisfaction will be a guideline for establishing a new future role between hospitals and facilities. This result will be used as a basic data for the renovation of long-term senior medicare insurance.