• Title/Summary/Keyword: Fabrication of denture

Search Result 109, Processing Time 0.025 seconds

A STUDY ON THE CHANGES IN RETENTION OF CLIPS USED TO RETAIN IMPLANT-SUPPORTED OVERDENTURE (임플랜트지지 overdenture용 clip의 유지력 변화에 관한 연구)

  • Yeo, Dong-Heon;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.4
    • /
    • pp.566-580
    • /
    • 1998
  • Implant-supported overdenture is known as a useful appliance, instead of using the conventional complete denture, for better retention and stability. In this study 4 types of materials such as, gold bar/plastic clip(group AuP), gold bar/metal clip(group AuM), palladium bar/plastic clip(group PdP), and palladium bar/metal clip (group PdM) were used to evaluate the retention forces according the type of clips and alloys used for bar fabrication, in the Hader bar system. Repeated insertions and removals of overdenture were conducted in each group. and the retention forces were measured and compared the data of each group according to the number of insertion and removal. The obtained results were as follows, 1. In the comparison of retention forces according to type of bar-clip, retention was increased in the order of group AuM, PdM, PdP AuP. and the retention force of group AuM was significantly increased compared with those of others (p<0.05). 2. In the comparison of retention forces according to the number of insertion, only group PdP showed significant decrease in retention(p<0.05). 3. In the comparison of retention forces according to the type of bar and clip. there was no significant difference in the type of bar, but the retention of plastic clip was significantly higher than that of metal clip when Au bar was used(p<0.05). 4. In the observation of the bar surface, group AuM using Au bar and metal clip showed the most scratches among bar groups.

  • PDF

Overdentures of the patient with Parkinson's disease: A case report (파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례)

  • Min, Byung-Kwee;Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.352-358
    • /
    • 2015
  • The retention of complete dentures in patients with Parkinson's disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant $Locator^{(R)}$ attachments of mandible in patients with Parkinson's disease. This report describes the fabrication of this functionally improved prosthesis.

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

  • Lima, Ana Paula Barbosa;Vitti, Rafael Pino;Amaral, Marina;Neves, Ana Christina Claro;Concilio, Lais Regiane da Silva
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.122-127
    • /
    • 2018
  • PURPOSE. This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (${\alpha}=.05$). RESULTS. The results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION. The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

Rehabilitation of edentulous maxilla with implant-supported milled bar overdenture using CAD/CAM customized abutment: A case report (CAD/CAM 맞춤형 지대주를 이용한 milled-bar 피개의치 증례)

  • Ji, Woon;Chang, Jae-Seung;Kwon, Joo-Hyun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • In patients with fully edentulous maxilla, fabrication of implant-supported overdenture can be a viable treatment option, when a minimum of six implants were strategically placed. Among several attachment systems used for implant-supported overdentures, milled-bars prevent rotational movement of denture, thus showing great stability, and have the advantage of splinting multiple implants with each other. In this case report, a milled-bar supported overdenture was fabricated for a patient suffering from condition of fully edentulous maxilla with severe ridge resorption in the anterior residual ridge. Seven implants composed of three different systems were effectively utilized by CAD/CAM customized abutment and cement-retained milled bar.

A Study on the Position of the Maxillary Anterior Teeth and Orientation of Occlusal Plane in Dentulous Korean Adults (한국 성인 유치악자의 상악전치 및 교합평면에 관한 연구)

  • Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.197-203
    • /
    • 2007
  • Statement of problem: It is very important to establish the suitable position for artificial maxillary anterior teeth and the orientation of occlusal plane in fabrication of the complete dentures. Incisive papilla has been considered the most useful anatomic landmark in the arranging of a maxillary anterior artificial teeth. Purpose: To determine correct position of upper anterior artificial teeth in complete denture patients, relationship of incisive papilla, intercanine line, occlusal plane were evaluated in Korean adults. Materials and Method: Maxillary casts were made in 60 Korean dentate subjects. Each cast was mounted in Hanau modular articulator using Hanau spring bow. Then, anatomic landmarks were determined in each cast. Distance from central incisor to incisive papilla, distance from incisive papilla to intercanine line and discrepancies between frankfurt plane and occlusal plane were measured and analysed. Results: 1. The mean distance between the posterior point of incisive papilla and the incisal edge of central incisor was 11.20 mm (in male 11.77 mm, in female 10.55 mm) and there was no significant difference in measured values between male and female 2. The mean distance between the posterior point of incisive papilla and intercanine line was 2.52 mm (Male 2.57 mm, Female 2.35 mm) and there were no significant differencies in measured values between male and female 3. The mean discripancy between the Frankfurt plane and the occlusal plane were 9. 75 degree (Male 9.81 degree, Female 9.55 degree), and there was no significant difference in measured values between left and right sides.

Implant-supported fixed prosthesis in patient with severe defects using staged GBR via 2-step augmentations: A case report (심한 결손부의 단계적 골증대술을 통한 임플란트 지지 고정성 보철 수복 증례 보고)

  • Oh, SaeEun;Jun, Ji Hoon;Park, YoungBum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.382-394
    • /
    • 2022
  • The treatment of patients with severe periodontitis should be proceeded step-bystep through an accurate diagnosis of each patients' individual tooth and with a strategic treatment plan. Implant-supported fixed prosthetic restoration has the advantage of high patient satisfaction and stable vertical dimension compared to the removable partial denture. However, multiple teeth defect areas lacking hard tissue may be disadvantageous in aesthetic failure and longer treatment time. In addition, it takes a certain period of time to manufacture and install a conventional fixed prosthesis, and during this process, the provisional prosthesis must satisfy the mechanical, biological, and aesthetic requirements of teeth. The purpose of this article is to describe the fabrication of implant-supported fixed prosthesis through a step-by-step approach in a partially edentulous patient.

Fabrication of palatal lift prosthesis using thermoplastic resin for a patient with velopharyngeal insufficiency (구개인두부전증 환자에서 열가소성레진을 이용해 연구개거상장치를 제작한 증례)

  • Jung, Hyun Jung;Kim, Jee Hwan;Lee, Sang-Hwy;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.286-290
    • /
    • 2016
  • Recently, flexible removable prosthesis with thermoplastic resin clasp has increasingly become popular. In comparison with conventionally used acrylic resin, thermoplastic resin has lower flexural strength and elastic modulus. Thus, flexible removable prosthesis has low risk of fracture, so denture base can be made thin and light, increasing patient comfort. Also, it can passively sit at tooth undercut during rest, so abutment teeth need minimum or no preparation. In this case report, a 44 year old female patient with mild velopharyngeal insufficiency was treated with a palatal lift prosthesis made of polyester thermoplastic resin. Since the patient had no missing tooth and desired conservative treatment, the flexible removable prosthesis provided relatively satisfactory results.

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

CAD-CAM technique based digital diagnosis and fixed partial denture treatment on maxillary congenital missing teeth with skeletal class III tendency patient: A case report (상악 선천성 결손과 하악 골격성 제3급 부정교합 경향성을 보이는 환자에게서 CAD-CAM 기법을 이용한 진단과 고정성 보철 수복 증례 보고)

  • Oh, SaeEun;Park, YoungBum;Park, JaeHan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.354-361
    • /
    • 2022
  • The development of digital technology is causing great changes in dentistry. This digital workflow combines various 3D data in the prosthetic treatment area for diagnosis and prosthetic manufacturing. The planned diagnosis and the fabrication of prosthesis in a virtual patient formed by synthesizing digital data can simulate the results of prosthetic treatment more intuitively than conventional methods, thereby increasing the predictability of aesthetic prosthetic treatment. In this case report, functionally and aesthetically satisfied clinical results were obtained by fabricating a fixed partial dentures through a digital workflow on congenital missing teeth in the maxillary anterior region.

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.