Radioaerosol inhalation imaging (RII) has been used in radionuclide pulmonary studies for the past 20 years. The method is well accepted for assessing regional ventilation because of its usefulness, easy fabrication and simple application system. To evaluate its clinical utility in the study of impaired regional ventilation in bronchial asthma, we obtained and analysed RIIs in 31 patients (16 women and 15 men; age ranging 21-76 years) with typical bronchial asthma at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical college, from January, 1988 to August, 1989. Scintiscans were obtained with radioaerosol produced by a BARC(Bhabha Atomic Reserch Center, India) nebulizer with 15 mCi of $^{99m}Tc-phytate$. The scanning was peformed in anterior, posterior and lateral projections following 5-minute inhalation of radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function study and the findings of chest radiography. Fifteen patients had concomitant lung perfusion image with $^{99m}Tc-MAA$. Follow-up scans were obtained in 5 patients after bronchodilator therapy. The patients were divided into (1) attack type (4 patients), (2) resistant type (5 patients), (3) remittent type (10 patients) and (4) bronchitic type (12 patients). Chest radiography showed hyperinflation, altered pulmonary vascularity, thickening of the bronchial wall and accentuation of basal interstitial markings in 26 of the 31 patients. Chest radiographs were norma! in the remaining 5 patients. Regardless of type, the findings of RII were basically the same, and characterized by the deposition of radioaerosol in the central parts or in the main respiratory air ways along with mottled nonsegmental ventilation defects in the periphery. Peripheral parenchymal defects were more extensive than that of expected findings from clinical symptoms, pulmonary function test and chest radiograph. Broomstick sign was present in 17 patients. The abnormality of RII was poorly correlated with perfusion scans. In all 5 patients treated with bronchodilators, follow-up study demonstrated a decrease in the degree of radioaerosol deposition in the central air way with improved ventilation defects. This study indicates that RII is a useful technique for the evaluation of regional ventilation abnormality and the effect of treatment with bronchodilators in patients with bronchial asthma.
RF magnetron co-sputtering법으로 PFN[$Pb(Fe_{0.5}Nb_{0.5}O_3(PFN)$]박막을 제조한 후 급속 열처리(rapid thermal annealing, RTA)하여 XRD(s-ray diffractometer)를 통한 박막의 상변 태 및 전기적 특성에 대하여 연구하였다. $SiO_2$/Si, ITO/glass, 및 Pt/Ti/$SiO_2$/Si기판에 PFN 박막을 증착시켰다. 기판의 변화에 따른 증착된 PFN박막의 조성변화는 관찰할 수 없었다. ITO/glass기판을 사용한 경우와 $SiO_2$/Si기판을 사용하여 증착시킨 PFN박막의 결정구조를 분석한 결과 ITO/glass기판에 증착한 시편이 perovskite상으로의 결정화가 더욱 우세하였다. 이는$SiO_2$기판의 경우 Pb의 확산에 의해 결정화가 잘 되지 못하기 때문이다. Pt/Ti/$SiO_2$/Si 기판 위에 증착시킨 PFN박막의 경우 perovskite상과 pyrochlore상이 공존하였다. Perovskite 상으로의 상변태에 대한 중요한 변수로는 열처리 온도와 Pb의 함량인 것이 확인되었으며, Pb의 함량이 화학양론적 조성비에 비해 5-10%정도 과량일수록 perovskite상으로의 상변태 온도가 낮아지고 상전이 정도가 향상되는 것으로 나타났으며, 급속 열처리 후 XRD를 이용 한 결정성 분석결과를 통해 결정한 perovskite상으로의 상전이 최저온도는 $500^{\circ}C$였다. Pb/(Fe+Nb)의 조성비가 1.17인 경우의 박막을 질소 분위기 하에서 $600^{\circ}C$로 30초간 급속열 처리 하였을 때 낮은 누설 전류 값과 1kHz에서 88의 유전 상수 값, 2.0$\mu$C/$\textrm{cm}^2$의 잔류 분극 값과 144kV/cm의 항전계 값을 얻었다.
본 연구에서는 원료 석탄 핏치와 흑연화성이 우수한 THF 가용성분만을 추출한 핏치 결합재에 8H/Satin woven fabric 프리프레그 및 고탄성 및 고강도계 연속 탄소섬유 등을 보강하여 가압열성형법으로 green body 를 제조한 다음 탄화, 함침, 재탄화 및 흑연화 공정을 거쳐 열적 미 기계적물성이 우수한 CFRC를 제조하였으며, 주사전자현미경, 편광현미경, X선회절분석,열중량분석, 굴곡강도, 굴곡탄성률, 충간전단강도 등을 시험하였다. THFSP결합재를 $2300^{\circ}C$까지 열처리 한 다음 X선회절분석을 한 결과, 결정성이 가장 우수하여 (002) 면에서 $C_0$/2인 값이 3.380$\AA$였으며, 2$\theta$값도 $26.276^{\circ}$로 천연흑연의 Bragg angle에 거의 접근하였으며 공기산화 반응특성을 시험하기 위하여 등온 열중량분석을 한 결과 $2300^{\circ}C$까지 흑연화 한 THFSP결합재가 산화에 대하여 가장 우수한 저항성을 나타내었다. 섬유용적률이 증가됨에 따라 65~70%까지는 기계적 물성이 중가하는 경향을 보였지만 그이상 섬유가 보강된 CFRC는 결합재의 부족으로 인하여 오히려 기계적 물성이 감소하였다. 또한 굴곡강도 시험후 주사전자현미경으로 파괴 단면을 관찰한 결과 THFSP결합재가 흑연화성이 우수하여 파괴시 결합재가 외력에 대한 흡수가 양호하여 보강재의 파괴를 억제했기 때문에 기계적 물성도 우수하게 나타났다.
PECVD법을 이용하여 $Al_2O_3$ 기판위에 증착된 $Fe_3O_4$박막의 상전이를 통하여 ${\gamma}-Fe_2O_3$ 박막을 제조하였다. ${\gamma}-Fe_2O_3$ 박막의 상전이는 주로 증착온도와 $Fe_3O_4$의 산화과정에 의해 유도되었다. $Fe_3O_4$ 상은 $200{\sim}300^{\circ}C$의 증착온도에서 in-situ로 얻을 수 있었다. 증착온도에 따른 상변화는 없었으며 $250^{\circ}C$에서 증착된 $Fe_3O_4$상이 가장 안정된 상을 나타내었다. ${\gamma}-Fe_3O_3$ 상은 $280{\sim}300^{\circ}C$의 온도범위에서 $Fe_3O_3$ 상을 산화시켜 유도하였다. $Fe_3O_4$ 상과 ${\gamma}-Fe_2O_3$ 상은 같은 spinel구조를 가지고 있으며 공존상으로서 존재함을 알 수 있었다. 또한, $Al_2O_3$에 산화된 ${\gamma}-Fe_2O_3$ 박막은 다공성의 미세구조를 나타내었다.
외경 1.02 mm, 내경 0.437 mm를 갖는 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 중공사를 상전이 방적기술로 제조하였다. 초기 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 선구 분말은 착체중합법을 이용하여 합성하였고, $900^{\circ}C$에서 하소하였다. 합성한 분말을 고분자 용액에 분산시킨 후 이중관형 노즐을 통해 중공사를 사출하였다. 최종적으로 산소분리에 사용 가능한 치밀 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 중공사막을 $1,080^{\circ}C$에서 2 시간 동안 소결하여 얻을 수 있었다. 또한 0.58 mm의 매우 얇은 분리막임에도 불구하고, BSCF 중공사 분리막은 602.5 MPa의 적당한 기계적 강도를 유지하였다.
본 연구에서는 HVPE을 이용하여 sapphire(001) 기판 위에 직경 2 inch, 두께 약 1.5 mm인 bulk GaN를 성장하고, 이를 mechanical polishing을 통해 $10{\times}10,\;15{\times}15$ mm 크기의 free-standing GaN template을 제작하여 그 특성을 평가하였다. 성장된 GaN 단결정의 X-ray diffraction pattern 결과 (002) 및 (004) 면으로부터의 회절에 의한 peak가 나타났으며, (002) 면의 DCXRD(Double crystal X-Ray diffraction) rocking curve peak의 반치폭(FWHM)은 98 arcsec으로 나타났다. 제작한 GaN template는 363 nm 파장에서 sharp한 PL spectrum을 나타내었으며, 불순물 defect에 의한 yellow 영역에서의 broad peak은 관찰되지 않았으며, 제작된 GaN template표면의 etch-pit 밀도는 $5{\times}10^6/cm^2$으로 매우 낮았다. 이러한 분석결과를 통하여 성장된 GaN template는 LED 및 LD 등의 청색 발광소자 및 고온, 고출력 소자용 기판재료로 응용이 가능할 것으로 생각 된다.
Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.
Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.
본 논문에서는 세그먼트 관형 고체산화물 연료전지(SOFC)의 설계 및 제작과 특성 분석을 다루고 있다. 관형 세라믹 지지체는 압출 공정을 통하여 제작하였으며, NiO-YSZ 연료극과 YSZ 전해질은 담금 코팅법을 통해 세라믹 지지체에 코팅하였다. 코팅된 세라믹 지지체를 $1,350^{\circ}C$에서 5시간 동안 열처리하였으며, $10{\mu}m$ 미만의 치밀하고, 균열이 없는 YSZ 전해질 층을 얻을 수 있었다. 또한 열처리된 세라믹 지지체에 LSM-YSZ/LSM/LSCF로 구성된 다층 구조 공기극을 담금법으로 코팅하여 $1,150^{\circ}C$에서 열처리하였다. 세라믹 관형 지지체에 코팅된 세그먼트 SOFC 셀은 Ag-glass 연결재를 사용하여 전기적으로 직렬 연결하였으며, 수소연료 유량과 운전 온도에 따른 세그먼트 SOFC의 성능 변화를 측정하였다.
최근 내화학성, 내마모성 및 내충격성이 뛰어나면서 재활용이 가능한 열가소성 폴리아미드 기반 복합재료를 제조하는 기술을 개발하기 위한 연구가 활발하다. 특히, 열가소성 고분자는 높은 점도로 용융 상태에서의 가공이 힘들기 때문에 저점도 단량체 상태로 금형 내부로 주입하면서 동시에 중합을 시키는 반응액상성형 공정이 큰 주목을 받고 있다. 그러나 단량체인 ε-카프로락탐은 중합속도가 매우 빠르고 외부 환경에 매우 민감하기 때문에 수지 함침과 중합 반응을 동시에 제어하면서 최적 공정조건을 확보하는 데 많은 어려움을 겪고 있는 실정이다. 따라서 본 연구에서는 ε-카프로락탐의 음이온 중합과정에서 주요한 공정 변수인 점도 변화 거동을 관찰하였고 ε-카프로락탐의 빠른 중합, 낮은 점도, 수분 민감성에 따른 측정상의 문제 원인을 분석하여 개선책을 제시하였다. 개선된 점도 측정 방법에 대한 재현성과 신뢰성은 여러 상대습도에 대한 점도 측정 그리고 외부 환경(수분, 산소)과 차단된 상황에서의 중합과 개선된 점도 측정 결과와의 비교를 바탕으로 검증하였으며, 이는 복합재료 반응액상성형 공정의 제어 인자로 활용함으로써 공정 최적화에 도움이 될 것으로 기대된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.