Carbon Nanotube Passivation layer for Increasing the Solar Water Splitting Performance of CdS/CuInGaSe Photocathode

  • Bae, Hyojung;Ko, Young-Hee;Park, Jun-Beom;Ko, Hang-Ju;Ryu, Sang-Wan;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.107-111
    • /
    • 2019
  • We report the fabrication of a CdS/CuInGaSe (CdS/CIGS) structure with carbon nanotubes and its application as a photocathode for photoelectrochemical water splitting. CIGS thin films were fabricated using co-evaporation by RF magnetron sputtering, while CdS was fabricated by chemical bath deposition. Spray coated multi-wall carbon nanotube (CNT) film on CdS/CIGS thin film was investigated as a photocathode. The CNT-coated CdS/CIGS showed superior photocurrent density and exhibited improved photostability.

Enhanced Cathode-Luminescence in a InxGa1-xN/InyGa1-y Green Light Emitting Diode Structure Using Two-Dimensional Photonic Crystals

  • Choi, Eui-Sub;Lee, Jae-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.276-279
    • /
    • 2008
  • We report on the enhancement of cathode-luminescence in an $In_xGa_{1-x}N/In_yGa_{1-y}$ green light emitting diode structure using two-dimensional photonic crystals. The square lattice arrays of photonic crystals with diameter/periodicity of 200/500 nm were fabricated by electron beam lithography. Inductively coupled plasma dry etching was used to etch and define photonic crystals. Three samples with different etch depths, i.e., 170, 95, and 65 nm, were constructed. Field emission scanning electron microscope analysis shows that air holes of photonic crystal structure with inverted-cone shapes were fabricated after dry etching. Cathode-luminescence measurement indicated that up to 30-fold enhancement of cathode-luminescence intensity has been achieved.

Polymer Thin-Film Transistors Fabricated on a Paper (종이 기판을 이용한 유기박막 트랜지스터의 제작)

  • Kim, Yong-Hoon;Moon, Dae-Gyu;Han, Jeong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.504-505
    • /
    • 2005
  • In this report, we demonstrate a high performance polymer thin-film transistor fabricated on a paper substrate. As a water barrier layer, parylene was coated on the paper substrate by using vacuum deposition process. Using poly (3-hexylthiophene) as an active layer, a polymer thin-film transistor with field-effect of up to 0.086 $cm^2/V{\cdot}s$ and on/off ratio of $10^4$ was achieved. The fabrication of polymer thin-film transistor built on a cheap paper substrate is expected to open a channel for future applications in flexible and disposable electronics with extremely low-cost.

  • PDF

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Design and Fabrication of High Temperature Superconducting Rapid Single Flux Quantum T Flip-Flop (고온 초전도 단자속 양자 T 플립 플롭 설계 및 제작)

  • Kim, J. H.;Kim, S. H.;Jung, K. R.;Kang, J. H.;Syng, G. Y.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.87-90
    • /
    • 2001
  • We designed a high temperature superconducting rapid single flux quantum(RSFQ) T flip-flop(TFF) circuit using Xic and WRspice. According to the optimized circuit parameters, we fabricated the TFF circuit with $Y_1$$Ba_2$Cu$_3$$O_{7-x}$(YBCO) interface-controlled Josephson junctions. The whole circuit was comprised of five epitaxial layers including YBCO ground plane. The interface-controlled Josephson junction was fabricated with natural junction barrier that was formed by interface-treatment process. In addition, we report second design for a new flip-flop without ground palne.e.

  • PDF

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

A Digital Approach to a Definitive Immediate Denture: A Clinical Report

  • Lee, Ju-Hyoung;Kim, Hyung Gyun
    • Journal of Korean Dental Science
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 2016
  • Even though an immediate denture (ID) is a practical prosthesis, fabricating an ID may be challenging, as unexpected removals of periodontally compromised teeth may occur during an impression procedure. This clinical report introduces a digital approach to a maxillary ID. An intraoral scanner was applied to prevent accidental extraction. A physical cast and a resin pattern of a framework were fabricated with rapid prototyping technology. A proper border and retention was also achieved by an altered cast impression.

Implants and all-ceramic restorations in a patient treated for aggressive periodontitis: a case report

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.97-101
    • /
    • 2010
  • A 23-year-old female with aggressive periodontitis was treated using dental implants and LAVA system. The severely compromised teeth were extracted irrespective of initial conservative periodontal treatment. An implant-supported overdenture with 4 implants was fabricated for the maxilla and all-ceramic restorations for the mandible. Esthetic and functional goals were achieved with team approach involving periodontists and prosthodontists. This case report describes a treatment procedure for a generalized aggressive periodontitis patient with severe bone resorption.

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.