• 제목/요약/키워드: FSR sensor

검색결과 58건 처리시간 0.022초

SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석 (Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors)

  • 장재식;정홍식
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.

저항센서와자이로센서를이용한새로운보행주기검출시스템의개발및평가 (Development and Evaluation of a New Gait Phase Detection System using FSR Sensors and a Gyrosensor)

  • 안승찬;황성재;강성재;김영호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.196-203
    • /
    • 2004
  • In this study, a new gait phase detection system using both FSR(Force Sensing Resister) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the posterior aspect of a shoe. An algorithm was also developed to determine eight different gait transitions among four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was compared with the conventional gait phase detection system using only FSR sensors in various gait experiments such as level walking, fore-foot walking and stair walking. In fore-foot walking and stair walking, the developed system showed much better accuracy and reliability to detect gait phases. The developed gait phase detection system using both FSR sensors and a gyrosensor will be helpful not only to determine pathological gait phases but to apply prosthetics, orthotics and functional electrical stimulation to patients with gait disorders.

Force Sensing Resistor를 이용한 인체압력중심 변화 분석 (Center of Pressure of a Human Body using Force Sensing Resistor)

  • 박철;박신석;김충현
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1722-1725
    • /
    • 2014
  • An experimental investigation of COP(center of pressure) was performed using FSR(force sensing resistor) and force plate. The FSR sensor system is used as effective device to detect the movement of human body in activities of daily living. It has been shown that the FSR provides the trajectories of COP with repeatability and reliability.

청각 피드백이 적용된 좌우 불균형 개선을 위한 밸런스 인솔 개발 및 검증 (The Development and Verification of Balance Insole for Improving the Muscle Imbalance of Left and Right Leg Using based Sound Feedback)

  • 강승록;윤영환;유창호;나재욱;홍철운;권대규
    • 재활복지공학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-124
    • /
    • 2017
  • 본 연구에서는 하지의 좌우 불균형 검출을 위한 밸런스 측정 인솔을 개발하고 불균형을 개선하기 위한 청각 피드백 기술에 대한 검증을 하고자 하였다. 밸런스 인솔은 실시간 압력 감지 범위가 64 단계이며 발바닥 압력분포를 고려해 8개 부위에 FSR 센서를 탑재한 FPCB로 구성되었다. 피험자는 하지의 좌우 근력차이가 20% 이상 차이가 나는 피험자 20명을 선출하였다. 피험자들은 경사 0, 5, 10%와 속도 3, 4, 5km/h 로 15분 간 트레드밀 위에서 보행을 하였다. 또한 보행 시 나타나는 좌우 불균형을 평가 및 청각 피드백에 따른 개선효과를 검증하기 위해 측정된 족압 센서 데이터와 실시간 근육생리신호 데이터를 비교분석하였다. 실험 결과, 보행경사와 속도가 증가할수록 하지 좌우의 근력 불균형을 보유한 피험자들은 75.7%~140.9%까지 증가하는 반면 청각 피드백을 제공 시 10% 이내로 감소하는 결과를 보였다. 본 연구에서 개발 인솔 시스템을 이용한 보행환경에 따른 인체 좌우 불균형 발생시 FSR 신호 감도 결과와 인체생리신호 간 유효한 결과를 보였다. 향후 밸런스 피드백 보행 시 하지 좌우 불균형 개선 효과 경향을 보여 향후 족부 영역별 FSR 센서 민감도, 불균형 검출 및 개선을 위한 역치점 처리 알고리즘 개발에 대한 연구가 필요하다고 사료된다.

저항 센서와 기울기 센서의 융합에 의한 보행 의도 감지 (Walking Intention Detection using Fusion of FSR and Tilt Sensor Signals)

  • 장은혜;전병태;이재연;지수영;강상승;조영조
    • 감성과학
    • /
    • 제13권3호
    • /
    • pp.441-448
    • /
    • 2010
  • 보행보조로봇은 고령화 사회에 노인 복지 및 중증 신경계 손상을 입은 환자에게 이동을 도울 수 있는 반드시 필요한 장비이다. 특히, 하지 마비 환자를 위한 보행보조로봇의 편리성을 위해서는 환자의 보행 의도를 내현적으로 파악함으로써 환자 의지에 따라 로봇을 통제할 수 있어야 한다. 본 논문은 보행 의도 감지 모델을 개발하기 위한 선행 연구로, 먼저 저항 센서와 기울기 센서의 융합을 통하여 3족 보행 모델을 기반으로 사용자의 보행 의도를 분석하였다. 저항 센서는 사용자의 양쪽 손바닥과 발바닥에 각각 부착되어, 부착된 위치의 압력을 센싱하였다. 양쪽 손바닥의 신호는 보행 의도를 파악하기 위해, 발바닥의 신호는 보행 단계를 확인하기 위하여 사용되었다. 기울기 센서는 몸의 움직임 상태를 측정하기 위한 센서로서, 사용자의 등 부분, 요추에 부착되어 상체의 움직임(roll, pitch)을 센싱하였다. 연구 결과, 사용자가 지팡이를 바닥에 짚을 때 양 손바닥에서 측정되는 2개의 저항 신호만으로 기본적인 보행 의도를 파악할 수 있었으나, 기울기 센서 정보를 함께 이용함으로써 오른발 뻗기, 왼발 뻗기 등의 움직임을 시작하려는 상태 등에 대한 보행 의도를 보다 구체적으로 확인할 수 있었다. 결론적으로, 본 연구를 통하여 저항센서와 기울기 센서의 융합에 기반한 사용자의 보행 의도를 감지할 수 있었다.

  • PDF

아두이노 센서와 LED를 활용한 움직임 모니터링 시스템 설계 (Design of Action Monitoring System Using Arduino Sensors and LEDs)

  • 박경석;황소영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.81-83
    • /
    • 2017
  • 우리 삶의 다양한 분야에서 ICT 기술을 적용하여 편의성과 활용성이 증대되고 있다. 본 논문에서는 최근 다양한 응용에 활용되고 있는 아두이노(Arduino)를 기반으로 사람의 움직임에 따라 이용할 수 있는 Accelerometer와 FSR 센서를 사용하여 RGB LED Strip을 제어하고 여러가지 색상을 다양한 패턴으로 나타나게 하며, 해당 움직임을 모니터링할 수 있는 시스템을 제안한다. 이는 사람의 움직임 또는 동작을 취하는 다양한 신체부위에 적용해 볼 수 있다.

  • PDF

Highly Sensitive Optical-fiber Humidity Sensor Based on Nafion-PVA Sol-gel

  • Ning, Wang;Yuhao, Li;Xiaolei, Yin;Wenting, Liu;Shiqi, Liu; Xuwei, Zhao; Yanxi, Zhong;Liang, Xu
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.21-27
    • /
    • 2023
  • A highly sensitive optical-fiber humidity sensor is demonstrated in this paper. By using Nafion-PVA sol-gel and single-mode optical fibers, the Fabry-Perot humidity sensor is easily fabricated. In the humidity range of 29%-72%, humidity-response experiments are carried out with a cycle of rising and falling humidity to investigate humidity-response characteristics. The experimental results show 2.25 nm/%RH sensitivity and a 0.9997 linear correlation coefficient, with good consistency. The changes in optical-path difference (OPD) and free spectral range (FSR) with humidity are also discussed. The humidity sensitivities of a typical sensor are 80.3 nm/%RH (OPD) and 0.03 nm/%RH (FSR). Furthermore, many humidity sensors with different Nafion-PVA sol-gel concentration and initial cavity length are experimentally investigated for humidity response. The results show that the sensitivity increases with higher Nafion ratio of the Nafion-PVA sol-gel. The influence of changing cavity length on sensitivity is not obvious. These results are helpful to research on optical-fiber humidity sensors with good performance, easy fabrication, and low cost.

Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.

Development of a Portable Gait Phase Detection System for Patients with Gait Disorders

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.145-150
    • /
    • 2005
  • A new gait detection system using both FSR (force sensing resistor) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the heel of a shoe. An algorithm was also developed to determine eight different gait transitions during four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was evaluated from nine heathy mans and twelve hemiplegic patients. Healthy volunteers were asked to walk in various gait patterns: level walking, fore-foot walking and stair walking. Only the level walking was performed in hemiplegic patients. The gait detection system was compared with a optical motion analysis system and the outputs of the FSR sensors. In healthy subjects, the developed system detected successfully more than $99\%$ for both level walking and fore-foot walking. For stair walking, the successful detection rate of the system was above$97\%$. In hemiplegic patients, the developed system detected approximately 98% of gait transitions. The developed gait phase detection system will be helpful not only to determine pathological gait phases but also to apply prosthetics, orthotics and functional electrical stimulation for patients with various gait disorders.

Force Sensing Resistor를 이용한 힘/모멘트 센서 개발 (Development of Force/Moment Sensor using Force Sensing Resistor)

  • 최명환;이우원
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.89-96
    • /
    • 2001
  • A low cost force./moment sensor that can be used in the robot teaching task is presented. Force Sensing Resistor is used as the transducer. The principle of force/moment detection is explained, the architecture of the sensor is shown, and the measurement of the force/moment is presented. The force/moment sensor shown in this work is not meant to be used in a precise force/moment control, but it is intended to be used in the robot teaching where low accuracy can be tolerated.

  • PDF